Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 11(5)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38790366

RESUMO

This study aimed to evaluate the inter-examiner reliability of shear wave elastography (SWE) for measuring cervical multifidus (CM) muscle stiffness in asymptomatic controls and patients with chronic neck pain. A longitudinal observational study was conducted to assess the diagnostic accuracy of a procedure. SWE images, following a detailed procedure previously tested, were acquired by two examiners (one novice and one experienced) to calculate the shear wave speed (SWS) and Young's modulus. The painful side was examined for the experimental cases while the side examined in the control group was selected randomly. Data analyses calculated the intra-class correlation coefficients (ICCs), absolute errors between examiners, standard errors of measurement, and minimal detectable changes. A total of 125 participants were analyzed (n = 54 controls and n = 71 cases). The Young's modulus and SWS measurements obtained by both examiners were comparable within the asymptomatic group (both, p > 0.05) and the chronic neck pain group (both, p > 0.05). Nonetheless, a notable distinction was observed in the absolute error between examiners for shear wave speed measurements among patients with neck pain, where a significant difference was registered (p = 0.045), pointing to a sensitivity in measurement consistency affected by the presence of chronic neck pain. ICCs demonstrated moderate-to-good reliability across both groups, with ICC values for asymptomatic individuals reported as >0.8. Among the chronic neck pain patients, ICC values were slightly lower (>0.780). The study revealed moderate-to-good consistency, highlighting the practicality and generalizability of SWE.

2.
Diagnostics (Basel) ; 12(12)2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36553059

RESUMO

Distal biceps brachii tendinopathy is a musculoskeletal pain condition-comprising chronic intrasubstance degeneration with alterations of the tendon structure-that is difficult to treat. Preliminary evidence suggests a positive effect for pain and related disability of percutaneous electrolysis treatment in patients with tendinopathy. Ultrasound is an excellent diagnostic tool to identify tendon injuries, such as tendinopathy, and to guide treatment approaches. Different approaches using ultrasound evaluation of the biceps tendon have been described. Our aim was to determine the validity and safety of a percutaneous electrolysis approach, targeting insertion of the distal tendon of biceps brachii, in both human (ultrasound-guided) and Thiel-embalmed cadaver (not ultrasound-guided) models. There were two approaches evaluated: an anterior approach with the elbow in extension and the forearm in supination and a posterior approach with the elbow in flexion and the forearm in pronation. A needle was inserted following the tendon up to its insertion into the radial tuberosity. The anterior approach, both in cadaveric study and US-guided intervention, revealed a close relationship between the distal biceps tendon and the brachial artery. The mean distance of the depth of the biceps tendon distal to the brachial artery was 0.21 ± 0.021 cm in the cadavers and 0.51 ± 0.024 cm in subjects. It was also found that the anterior approach has a potential technical difficulty due to the anatomical location of the brachial artery. With the posterior approach, it was possible to safely identify the tendon insertion and the needle approach, since no important vascular and nervous structures were visualized in the window of insertion of the needle. The clinician rated the posterior approach as low difficulty in all subjects. Current results would support a posterior approach with US guidance as a safe approach for applying the percutaneous electrolysis technique for insertional tendinopathies of the distal biceps brachii tendon. The current study did not assess the effectiveness of the proposed intervention; accordingly, future studies investigating the clinical effectiveness of the proposed intervention are needed.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36231206

RESUMO

Achilles tendon tendinopathy (AT) is a musculoskeletal condition characterized by pain in the Achilles tendon and impaired physical performance or sport activities. AT is difficult to treat, and the results are variable. Preliminary evidence suggests a positive effect for pain of percutaneous electrolysis in patients with tendinopathy. Our aim was to determine the validity and safety of a percutaneous electrolysis approach targeting the interphase between the Achilles tendon and the Kager's fat with ultrasound imaging in both healthy individuals and on a fresh cadaver model (not ultrasound guiding). A needle was inserted from the medial to the lateral side under the body of the Achilles tendon, just between the tendon and the Kager's triangle, about 5 cm from the insertion of tendon in the calcaneus in 10 healthy volunteers (ultrasound study) and 10 fresh cadaver legs. An accurate needle penetration of the interphase was observed in 100% of the approaches, in both human and cadaveric models. No neurovascular bundle of the sural nerve was pierced in any insertion. The distance from the tip of the needle to the sural nerve was 5.28 ± 0.7 mms in the cadavers and 4.95 ± 0.68 mms in the volunteer subjects, measured in both cases at a distance of 5 cm from the insertion of the Achilles tendon. The results of the current study support that percutaneous electrolysis can be safely performed at the Kager's fat-Achilles tendon interphase if it is US guided. In fact, penetration of the sural nerve was not observed in any needle approach when percutaneous needling electrolysis was performed by an experienced clinician. Future studies investigating the clinical effectiveness of the proposed intervention are needed.


Assuntos
Tendão do Calcâneo , Tendinopatia , Tendão do Calcâneo/diagnóstico por imagem , Cadáver , Eletrólise , Humanos , Dor , Projetos Piloto , Tendinopatia/diagnóstico por imagem , Tendinopatia/terapia , Ultrassonografia/métodos
4.
Tomography ; 8(4): 1726-1734, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35894010

RESUMO

We aimed to investigate clinical and ultrasound signs of shoulder overuse injuries in professional bullfighters; side-to-side differences (dominant vs. non-dominant); and to determine potential differences according to bullfighters' categories. An observational cross-sectional study was conducted. Thirty professional and active bullfighters were assessed. A bilateral ultrasound assessment of the subacromial bursa, long biceps head tendon (LHBT), and rotator cuff was performed to determine the presence of bursitis, subluxation, partial or total tendon rupture, tenosynovitis, or calcification. Supraspinatus tendon thickness was measured. Finally, a battery of clinical orthopedic tests (Yergason, Jobe, infraspinatus, Gerber, and bursa tests) were also performed. Most identified ultrasound findings were located in the dominant side, being the presence of bursitis (n = 9; 30%), LHBT tenosynovitis (n = 8; 26.7%), and subscapularis tendon calcification (n = 5; 16.7%) the most prevalent. No side-to-side or between-categories differences were found for supraspinatus tendon thickness (all, p > 0.05). The most frequent positive signs were the infraspinatus test (40.0%), Gerber lift-off test (33.3%), and bursitis, Jobe, and Yergason tests (all, 26.7%). Ultrasound signs were commonly found at LHBT, subacromial bursa, and rotator cuff in professional bullfighters without difference between categories and sides. No side-to-side or between-categories differences were found. Positive clinical test signs suggestive of bursitis, LHBT, and rotator cuff tendinopathy were frequently observed.


Assuntos
Bursite , Calcinose , Lesões do Manguito Rotador , Lesões do Ombro , Tenossinovite , Bursite/diagnóstico por imagem , Bursite/epidemiologia , Estudos Transversais , Humanos , Prevalência , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/epidemiologia , Ombro/diagnóstico por imagem , Lesões do Ombro/diagnóstico por imagem , Lesões do Ombro/epidemiologia , Ultrassonografia
5.
Artigo em Inglês | MEDLINE | ID: mdl-35206659

RESUMO

Entrapment of the radial nerve at the arcade of Frohse could contribute to symptoms in patients with lateral epicondylalgia or radial tunnel syndrome. Our aim was to determine the validity of applying percutaneous electrolysis, targeting the supinator muscle at the Frohse's arcade with ultrasound imaging and in a Thiel-embalmed cadaver model (not ultrasound-guiding). Percutaneous electrolysis targeting the supinator muscle was conducted in five healthy volunteers (ultrasound study) and three Thiel-embalmed cadaver forearms. Two approaches, one with the forearm supinated and other with the forearm pronated were conducted. The needle was inserted until the tip reached the interphase of both bellies of the supinator muscle. Accurate needle penetration of the supinator muscle was observed in 100% in both US-imaging and cadaveric studies. No neurovascular bundle of the radial-nerve deep branch was pierced in any insertion. The distance from the tip of the needle to the neurovascular bundle was 15.3 ± 0.6 mm with the forearm supinated, and 11.2 ± 0.6 mm with the forearm pronated. The results of the current study support that percutaneous electrolysis can properly target the supinator muscle with either the forearm in supination or in pronation. In fact, penetration of the neurovascular bundle was not observed in any approach when percutaneous needling electrolysis was performed by an experienced clinician.


Assuntos
Neuropatia Radial , Cadáver , Eletrólise , Humanos , Nervo Radial/anatomia & histologia , Ultrassonografia
6.
J Orthop Case Rep ; 11(9): 90-93, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35415178

RESUMO

Introduction: Latissimus dorsi ruptures are rare injuries more commonly seen in elite overhead and hip throwers athletes. The most frequent mechanism of injury is indirect. The management of these injuries is unclear and controversial. Case Presentation: In this case report we present a professional female handball player with an acute intramuscular/costal tear of the latissimus dorsi, managed operatively. The patient injured extremity was the dominant throwing arm with a palpable muscle gap of 3 cm. Operative treatment was taken and objective follow-up using UCLA shoulder rating scale and DASH scores; demonstrating a progressive improvement between day zero (UCLA 13pts and DASH 36.7 pts) and the final 6 months (UCLA 33pts and DASH 0.8 pts) follow up; returning to sport at 12 weeks. Conclusion: Latissimus dorsi costal tears are uncommon injuries that can also be seen in hip throwing athletes. Surgical management should be considered if the dominant arm is affected and a 3cm muscle gap is present.

7.
J Manipulative Physiol Ther ; 41(7): 589-595, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30442357

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the immediate effect of thoracic spine manipulation upon active flexion and abduction mobility of the shoulder, spine temperature, and the size of the subacromial space as measured by ultrasound in 3 positions (internal, neutral, and external rotation) of the glenohumeral joint in patients who have undergone surgery because of subacromial impingement. METHODS: Quasi-experimental, prospective, short-term effect study with consecutively sampled participants. Thirty-two patients had undergone subacromial decompression together with supraspinatus tendon suture. The following variables were studied: age, sex, dominant shoulder, presurgery evolution time, working status, surface temperature of dorsal segment with limited mobility, premanipulation functional assessment using the Spanish version of the Upper Limb Functional Index Scale, goniometric range of motion measurement at glenohumeral joint before and after manipulation, and ultrasound measurement of subacromial space before and after manipulation. RESULTS: Significant differences and small effect size were found in measurements for flexion and abduction movements after thoracic spine manipulation (P > .001; ES > 0.2) and subacromial space measurements in neutral rotation and external rotation (P > .001), but without clinical relevance effect size (<0.2). CONCLUSIONS: Active shoulder flexion and abduction mobility increase after manipulation of thoracic spine in patients who have undergone surgery for rotator cuff suture. Subacromial space increases significantly with shoulder in neutral and external rotation position after manipulation. No differences were found regarding surface temperature of manipulated area.


Assuntos
Manipulação da Coluna , Manguito Rotador/cirurgia , Síndrome de Colisão do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Vértebras Torácicas/fisiologia , Adulto , Descompressão Cirúrgica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...