Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. bras. ginecol. obstet ; Rev. bras. ginecol. obstet;39(9): 471-479, Sept. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-898904

RESUMO

Abstract Objective Using three-dimensional ultrasound (3D-US), we aimed to compare the tape position and the angle formed by the sling arms in different techniques of midurethral sling insertion for the surgical treatment of stress urinary incontinence, three years after surgery. In addition, we examined the correlations between the US findings and the clinical late postoperative results. Methods A prospective cross-sectional cohort study of 170 patients who underwent a sling procedure between May 2009 and December 2011 was performed. The final sample, with US images of sufficient quality, included 26 retropubic slings (tension-free vaginal tape, TVT), 42 transobturator slings (tension-free vaginal tape-obturator, TVTO), and 37 single-incision slings (tension-free vaginal tape-Secur, TVT-S). The images (at rest, during the Valsalva maneuver, and during pelvic floor contraction) were analyzed offline by 2 different observers blinded against the surgical and urinary continence status. Group comparisons were performed using the Student t-test, the chi-squared and the Kruskal-Wallis tests, and analyses of variance with Tukey multiple comparisons. Results Differences among the groups were found in themean angle of the tape arms (TVT = 119.94°, TVT-O = 141.93°, TVT-S = 121.06°; p < 0.001) and in the distance between the bladder neck and the tape at rest (TVT = 1.65 cm, TVT-O = 1.93 cm, TVTS = 1.95 cm; p = 0.010). The global objective cure rate was of 87.8% (TVT = 88.5%, TVT-O = 90.5%, TVT-S = 83.8%; p = 0.701). The overall subjective cure rate was of 83.8% (TVT = 88.5%, TVT-O = 88.5% and TVT-S = 78.4%; p = 0.514). The slings were located in the mid-urethra in 85.7% of the patients (TVT = 100%, TVT-O = 73.8%, TVTS = 89.2%; p = 0.001), with a more distal location associated with obesity (distal: 66.7% obese; mid-urethra: 34% obese; p = 0.003). Urgency-related symptoms were observed in 23.8% of the patients (TVT = 30.8%, TVT-O = 21.4%, TVT-S = 21.6%; p = 0.630). Conclusions The angle formed by the arms of the sling tape was more obtuse for the transobturator slings compared with the angles for the retropubic or single-incision slings. Retropubic slings were more frequently located in the mid-urethra compared with the other slings, regardless of obesity. However, the analyzed sonographic measures did not correlate with the urinary symptoms three years after the surgery.


Resumo Objetivo Comparar por meio de ultrassom tridimensional (US-3D) a posição e o ângulo entre os braços da faixa, em diferentes técnicas de inserção de sling de uretra média, para tratamento de incontinência urinária de esforço, 3 anos após a cirurgia, correlacionando os achados ultrassonográficos aos resultados clínicos pós-operatórios. Métodos Este é umestudo de coorte transversal prospectivo de 170 pacientes que se submeteram a um procedimento de sling entremaio de 2009 e dezembro de 2011. Foi possível avaliar as imagens de US em 105 pacientes: 26 com tension-free vaginal tape (TVT), 42 com tension-free vaginal tape-obturator (TVT-O) e 37 com tension-free vaginal tape-Secur (TVT-S). As imagens (em repouso, em manobra de Valsalva e em contração perineal) foram analisadas por dois observadores diferentes, que desconheciam o tipo de sling utilizado na cirurgia, assimcomo as queixas da paciente. A análise estatística foi realizada por meio dos testes t de Student, qui-quadrado, Kruskal-Wallis, e análise de variância com comparações múltiplas de Tukey. Resultados As médias dos ângulos entre os braços da faixa foram: TVT = 119,94°, TVT-O = 141,93°, TVT-S = 121,06° (p < 0,001). As médias das distâncias entre o colo vesical e a faixa, em repouso, foram: TVT = 1,65 cm, TVT-O = 1,93 cm, TVTS = 1,95 cm (p = 0,010). A taxa de cura objetiva dos slings foi de 87,8% (TVT = 88,5%, TVT-O = 90,5% e TVT-S = 83,8%; p = 0,701). A taxa de cura subjetiva foi de 83,8% (TVT = 88,5%, TVT-O = 88,5% e TVT-S = 78,4%; p = 0,514). Os slings estavam na uretra média em 85,7% (TVT = 100%, TVT-O = 73,8% e TVT-S = 89,2%; p = 0,001) dos pacientes, e a localização mais distal foi associada a obesidade (distal: 66,7% obesas; uretra média: 34% obesas; p = 0.003). Os sintomas de urgência foram observados em 23,8% das pacientes (TVT = 30,8%, TVT-O = 21,4%, TVT-S = 21,6%; p = 0,630). Não houve diferenças significativas quando se comparam os achados ultrassonográficos e os grupos de pacientes com sintomas de urgência, cura subjetiva e objetiva. Conclusão O ângulo formado pelos braços da faixa foi mais obtuso noTVT-Oquando comparado com o TVT ou o TVT-S. Os TVTs foram localizados mais frequentemente na uretra média quando comparados com os outros dois grupos, mesmo em pacientes obesas. Entretanto, as medidas ultrassonográficas não tiveram correlação com os sintomas urinários três anos após a cirurgia.


Assuntos
Humanos , Feminino , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/diagnóstico por imagem , Diafragma da Pelve/diagnóstico por imagem , Imageamento Tridimensional , Slings Suburetrais , Fatores de Tempo , Estudos Transversais , Estudos Prospectivos , Seguimentos , Ultrassonografia , Pessoa de Meia-Idade
2.
Rev Assoc Med Bras (1992) ; 56(3): 348-54, 2010.
Artigo em Inglês, Português | MEDLINE | ID: mdl-20676545

RESUMO

OBJECTIVE: To compare the results of retropubic and transobturator slings for surgical treatment of female stress urinary incontinence (SUI). METHODS: We randomized thirty patients with SUI, ten of whom underwent transobturator sling surgery and ten retropubic sling surgery. Patients were assessed before treatment and 1, 6 and 12 months after treatment on the basis of clinical history, physical examination, quality of life questionnaire (King's Health Questionnaire), pad test and urodynamic evaluation. The groups were homogenous prior to surgery. RESULTS: One year after surgery, incontinence and quality of life parameters had improved significantly in both groups and there were no differences between them. There was a significant reduction in pad test weights in both groups. According to the urodynamic evaluation, 12 months after surgery cure rates were 84.2% for the transobturator group and 88.8% for the retropubic group. Subjective cure rates were 85% in the transobturator group and 88.8% in the retropubic group. No statistical difference was observed in complication rates. CONCLUSION: Retropubic and transobturator slings were effective for treatment of women with SUI at 12-month follow-up. Both techniques had significant cure rates and improved quality of life with low complication rates.


Assuntos
Qualidade de Vida , Slings Suburetrais , Incontinência Urinária por Estresse/cirurgia , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Estatísticas não Paramétricas , Resultado do Tratamento , Incontinência Urinária por Estresse/fisiopatologia , Urodinâmica/fisiologia , Procedimentos Cirúrgicos Urológicos/métodos
3.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);56(3): 348-354, 2010. tab
Artigo em Português | LILACS | ID: lil-553287

RESUMO

OBJETIVO: Comparar resultados das técnicas de "sling" retropúbico e transobturador para o tratamento de mulheres com incontinência urinária de esforço (IUE). MÉTODOS: Foram randomizadas 30 pacientes, sendo que 20 se submeteram ao sling retropúbico e 10 ao transobturador. As pacientes foram avaliadas antes e após o tratamento com um, seis e 12 meses, por meio de história clínica, exame físico, questionário de qualidade de vida ("King's Health Questionnaire"), teste do absorvente e avaliação urodinâmica. Os grupos foram homogêneos no pré-operatório. RESULTADOS: Houve melhora significante na avaliação da qualidade de vida em ambos os grupos após a terapêutica, sem diferença entre os grupos. Houve diminuição no peso do absorvente para os dois grupos. As taxas de cura pela avaliação urodinâmica em 12 meses foram de 84,2 por cento para o grupo transobturador e 88,8 por cento para o retropúbico. Da mesma forma, a cura subjetiva foi de 85 por cento e 88,8 por cento, respectivamente. Não observamos diferenças entre os grupos consoante as complicações. CONCLUSÃO: As cirurgias deste sling, pelas vias retropúbica e transobturadora, foram eficazes para o tratamento de mulheres com IUE, no seguimento de 12 meses. Observamos elevada taxa de cura e melhora da qualidade de vida com baixos índices de complicações.


OBJECTIVE: The aim of this study was to compare results of retropubic and transobturator sling for surgical treatment of female stress urinary incontinence (SUI). METHODS: Thirty randomized patients with SUI were divided in two groups, twenty who underwent the transobturator sling and ten the retropubic sling procedure. .Patients were assessed before and after one, six and twelve months of treatment by clinical history, physical examination, quality of life questionnaire (King's Health Questionnaire), pad test and urodynamic parameters. At preoperative both groups were homogenous. RESULTS: One year after surgery, incontinence and quality of life questionnaire parameters had improved significantly in both groups and there was no difference between them. There was significant reduction in the pad test in both groups. Concerning urodynamic evaluation, one year after surgery cure rates were 84.2 percent for the transobturator group and 88.8 percent for the retropubic,. Subjective cure rate was 85 percent in the transobturator group and 88.8 percent in the retropubic. No statistical difference was found in complications rates. CONCLUSION: Retropubic and transobturator slings were effective in treatment of female SUI at one-year follow-up. Both techniques had significant cure rates and improved the quality of life with few complications.


Assuntos
Feminino , Humanos , Qualidade de Vida , Slings Suburetrais , Incontinência Urinária por Estresse/cirurgia , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Seguimentos , Estatísticas não Paramétricas , Resultado do Tratamento , Incontinência Urinária por Estresse/fisiopatologia , Urodinâmica/fisiologia , Procedimentos Cirúrgicos Urológicos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA