Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Ann Anat ; 250: 152147, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37595931

RESUMO

BACKGROUND: Practicing on the human body was considered extremely relevant for health professionals' education, but a drastic reduction was observed due to an increase in alternative virtual and multimedia means, and, in Italy, also due to a lack of regulation. Italian Law 10/2020 regulates body donation for research and training through an advanced directive for post-mortem body donation. METHODS: A cross-sectional study was carried out to investigate the law knowledge and body donation perception of health students of any degree courses enrolled at the University of Pavia, Italy, in 2021, through ad hoc web questionnaire. RESULTS: 485 students participated to this survey; median age was of 21 years (25th-75th percentiles, 20-23), 73.2% were females, and 62.5% were medical students. Among them 14.9% knew the Italian law 10/2020. Age was the only variable associated with students' knowledge of the law. Further, 8.3% reported the current availability of cadaveric practice, 85.6% of health students acknowledged usefulness of cadaveric practice, with a significant difference between medical and non-medical students (71.4% vs 28.6%, p < 0.001). Overall, 59.7% would donate their body, rising to 62.7% with reference to specific law regulation, with 30.5% and 28.7% undecided, respectively. 51.3% of participants answered not practicing religious faith, 82.9% with Catholic families, without significance on the knowledge of the law. CONCLUSIONS: Poor knowledge of the law compared with great interest and acknowledged cadaveric practice usefulness highlighted the need for better information, especially among health students, where critical discussion could be more valuable. Then, there arises the urgent need to fill the gaps within university studies and syllabuses, to relaunch the central role that cadaveric practice and research had in the education of health professionals. Consequences on basic and specific health students' skills, on health education quality in general, and further on health professionals' expertise must be carefully considered.


Assuntos
Estudantes de Medicina , Obtenção de Tecidos e Órgãos , Feminino , Humanos , Adulto Jovem , Adulto , Masculino , Estudos Transversais , Inquéritos e Questionários , Itália , Cadáver , Percepção , Conhecimentos, Atitudes e Prática em Saúde
2.
Int J Legal Med ; 137(4): 1093-1096, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36939873

RESUMO

The furcate insertion of the umbilical cord is an uncommon abnormality, often asymptomatic, potentially dangerous, or lethal for the fetus and the mother. This report shows the case of a healthy 29-year-old patient, at 37 weeks of gestation, admitted to the hospital two days before the due date because of the appearance of uterine contractions; clinical exams were regular. The following day, no fetal movements were perceived, a cardiotocography was performed, showing the absence of fetal heartbeat. A dead fetus was delivered. Autopsy showed furcate insertion of the umbilical cord and the rupture of the umbilical vessel, which caused fetal hemorrhagic shock. Furcate insertion still remains mostly undiagnosed and rarely it can be identified prenatally (only three cases are reported in literature). Future research, mainly in forensic fields, could improve the knowledge about this condition, helping prenatal diagnosis and providing warnings that can prevent similar deaths in the future.


Assuntos
Responsabilidade Legal , Cordão Umbilical , Gravidez , Feminino , Humanos , Adulto , Morte Fetal/etiologia , Natimorto , Feto
3.
J Forensic Leg Med ; 93: 102462, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36516716

RESUMO

A 45-years-old Indonesian woman was admitted to the hospital with nausea, vomiting, abdominal pain and tachyarrhythmia. Atrial fibrillation was found at ECG, blood tests showed mild hepatic function alterations. Radiological exams showed bilateral pleural effusions, ascites, hepatomegaly. Systolic and diastolic functions of the left ventricle were found to be strongly compromised at US. Physical conditions and laboratory results worsened rapidly, followed by multi organ failure. Death occurred 28 hours after admission. An autopsy was performed to clarify the cause of death and investigated medical malpractice. External examination showed jaundice skin and at internal examination bilateral pleural and pericardial effusions, ascites, mild cardiomegaly, ventricular endocardial fibrosis, a thrombus in tight junction to the left ventricular wall and hepatic necrosis were observed. Histological investigations revealed a massive endomyocardial fibrosis, detected through Azan-Mallory and Verhoef-Van-Gieson stain, and confirmed the presence of hepatic and renal necrosis. Toxicological and microbiological investigations were negative. The cause of death was a global cardiac dysfunction caused by a restrictive cardiomyopathy in an Indonesian woman affected by an undiagnosed and asymptomatic endomyocardial fibrosis. In this case, autopsy and histopathological investigations were fundamental to diagnose an occult endomyocardial fibrosis, which is an idiopathic disorder of tropical and subtropical regions of the world. The not common incidence of this disease in our country and its unusual clinical onset were at first perceived as a medical malpractice from the relatives. Consequently, the clinical aspects of the case intertwine with the medicolegal implications concerning the undiagnosed disease and the causality with the patient's death.


Assuntos
Cardiomiopatia Restritiva , Fibrose Endomiocárdica , Derrame Pericárdico , Feminino , Humanos , Pessoa de Meia-Idade , Fibrose Endomiocárdica/diagnóstico , Fibrose Endomiocárdica/patologia , Cardiomiopatia Restritiva/diagnóstico , Cardiomiopatia Restritiva/etiologia , Diagnóstico Diferencial , Ascite/complicações , Ascite/diagnóstico , Morte Súbita , Necrose
4.
Cells ; 11(19)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36231087

RESUMO

Here, we aim to describe COVID-19 pathology across different tissues to clarify the disease's pathophysiology. Lungs, kidneys, hearts, and brains from nine COVID-19 autopsies were compared by using antibodies against SARS-CoV-2, macrophages-microglia, T-lymphocytes, B-lymphocytes, and activated platelets. Alzheimer's Disease pathology was also assessed. PCR techniques were used to verify the presence of viral RNA. COVID-19 cases had a short clinical course (0-32 days) and their mean age was 77.4 y/o. Hypoxic changes and inflammatory infiltrates were present across all tissues. The lymphocytic component in the lungs and kidneys was predominant over that of other tissues (p < 0.001), with a significantly greater presence of T-lymphocytes in the lungs (p = 0.020), which showed the greatest presence of viral antigens. The heart showed scant SARS-CoV-2 traces in the endothelium-endocardium, foci of activated macrophages, and rare lymphocytes. The brain showed scarce SARS-CoV-2 traces, prominent microglial activation, and rare lymphocytes. The pons exhibited the highest microglial activation (p = 0.017). Microthrombosis was significantly higher in COVID-19 lungs (p = 0.023) compared with controls. The most characteristic pathological features of COVID-19 were an abundance of T-lymphocytes and microthrombosis in the lung and relevant microglial hyperactivation in the brainstem. This study suggests that the long-term sequelae of COVID-19 derive from persistent inflammation, rather than persistent viral replication.


Assuntos
COVID-19 , Trombose , Idoso , Antígenos Virais , Encéfalo/patologia , Humanos , Rim , Pulmão/patologia , Macrófagos , RNA Viral , SARS-CoV-2 , Linfócitos T , Trombose/patologia
5.
Front Med (Lausanne) ; 9: 863945, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35492348

RESUMO

Pelvic organ prolapse (POP) affects many women and contributes significantly to a decrease in their quality of life causing urinary and/or fecal incontinence, sexual dysfunction and dyspareunia. To better understand POP pathophysiology, prevention and treatment, many researchers resorted to evaluating animal models. Regarding this example and because POP affects principally older women, our aim was to provide an overview of literature on the possible biomechanical changes that occur in the vaginas of animal models and their supportive structures as a consequence of aging. Papers published online from 2000 until May 2021 were considered and particular attention was given to articles reporting the effects of aging on the microscopic structure of the vagina and pelvic ligaments in animal models. Most research has been conducted on rodents because their vagina structure is well characterized and similar to those of humans; furthermore, they are cost effective. The main findings concern protein structures of the connective tissue, known as elastin and collagen. We have noticed a significant discordance regarding the quantitative changes in elastin and collagen related to aging, especially because it is difficult to detect them in animal specimens. However, it seems to be clear that aging affects the qualitative properties of elastin and collagen leading to aberrant forms which may affect the elasticity and the resilience of tissues leading to pelvic floor disease. The analysis of histological changes of pelvic floor tissues related to aging underlines how these topics appear to be not fully understood so far and that more research is necessary.

6.
Radiol Med ; 127(6): 589-601, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35435606

RESUMO

PURPOSE: Today there is a growing interest in the quantification of late gadolinium enhancement (LGE) in ischemic and non-ischemic cardiac pathologies. We build an automatic self-made free software FLORA (For Late gadOlinium enhanced aReas clAssification) for the recognition, classification and quantification of LGE areas that allows to improve the observer's performances and that homogenizes the evaluations between different operators. MATERIAL AND METHODS: We have retrospectively selected 120 CMR exams: 40-ischemic with evident scar tissue on LGE sequences; 40-non-ischemic cardiomyopathy; 40-any myocardial alteration on CMR, especially on LGE sequences. FLORA's performance was compared to the radiologist's evaluation. RESULTS: FLORA identified both ischemic and non-ischemic myocardial lesions in almost all cases (80/80 and 79/80 for the double-Gaussian fit method and fixed-shift method, respectively, with sensitivity and specificity of 100%/98.8% and 55%/50%, respectively). The best results were obtained from the classification of ischemic myocardial damage, which was correctly identified in 85%-95% of cases. FLORA also increases the agreement between observers and allows a quantitative evaluation of transmurality. CONCLUSIONS: FLORA has proven to be an applicable tool that improves and facilitates the classification of LGE areas allowing their quantification.


Assuntos
Cardiomiopatias , Gadolínio , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Estudos Retrospectivos , Software
7.
Phys Med ; 85: 98-106, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33991807

RESUMO

PURPOSE: The purpose of this multicenter phantom study was to exploit an innovative approach, based on an extensive acquisition protocol and unsupervised clustering analysis, in order to assess any potential bias in apparent diffusion coefficient (ADC) estimation due to different scanner characteristics. Moreover, we aimed at assessing, for the first time, any effect of acquisition plan/phase encoding direction on ADC estimation. METHODS: Water phantom acquisitions were carried out on 39 scanners. DWI acquisitions (b-value = 0-200-400-600-800-1000 s/mm2) with different acquisition plans (axial, coronal, sagittal) and phase encoding directions (anterior/posterior and right/left, for the axial acquisition plan), for 3 orthogonal diffusion weighting gradient directions, were performed. For each acquisition setup, ADC values were measured in-center and off-center (6 different positions), resulting in an entire dataset of 84 × 39 = 3276 ADC values. Spatial uniformity of ADC maps was assessed by means of the percentage difference between off-center and in-center ADC values (Δ). RESULTS: No significant dependence of in-center ADC values on acquisition plan/phase encoding direction was found. Ward unsupervised clustering analysis showed 3 distinct clusters of scanners and an association between Δ-values and manufacturer/model, whereas no association between Δ-values and maximum gradient strength, slew rate or static magnetic field strength was revealed. Several acquisition setups showed significant differences among groups, indicating the introduction of different biases in ADC estimation. CONCLUSIONS: Unsupervised clustering analysis of DWI data, obtained from several scanners using an extensive acquisition protocol, allows to reveal an association between measured ADC values and manufacturer/model of scanner, as well as to identify suboptimal DWI acquisition setups for accurate ADC estimation.


Assuntos
Imagem de Difusão por Ressonância Magnética , Análise por Conglomerados , Difusão , Imagens de Fantasmas , Reprodutibilidade dos Testes
8.
Magn Reson Imaging ; 76: 1-7, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33161101

RESUMO

PURPOSE: The aim of this work is to test the use of aqueous solutions of Ficoll®**, a highly branched polymer displaying crowding properties, to build a phantom suitable for Diffusion Weighted Imaging (DWI) in Magnetic Resonance Imaging (MRI). METHODS: We developed a test object made of a cylindrical plastic container with a precise geometrical arrangement suitable for measuring several samples at the same time. The container was designed to host single vials with variable geometry and number, and to fit inside common commercial head coils for MRI scanners. In our experiments, vials were filled with 8 aqueous solutions of Ficoll 70 and Ficoll 400 spanning a range of polymer concentration from 5 to 30% by weight. Vials containing ultra-pure water were also used as reference. Experiments were performed on both 1.5 and 3 T clinical scanners (GE, Philips and Siemens), under the conditions of a standard clinical examination. RESULTS: The geometry of the phantom provided reduced imaging artifacts, especially image distortions at magnetic interfaces. We found that the Apparent Diffusion Coefficient (ADC) varied in the range of 0.00125-0.00223 mm2/s and decreased with Ficoll concentration. ADC vs Ficoll concentration exhibited a linear trend. Results were consistent over time and among different MRI clinical scanners, showing an average variability of 3% at 1.5 T and of 7.5% at 3 T. Moreover, no substantial difference was found between Ficoll 70 and 400. By varying Ficoll concentration, ADC can be modulated to approach tissue-mimicking values. Preliminary results for relaxation measurements proved that both T1 and T2 decreased with Ficoll concentration in the ranges 1.3-2.4 s and 150-800 ms respectively. CONCLUSIONS: In this work, we propose a 3D phantom design based on the widespread crowding agent Ficoll, which is suitable for DWI quality assurance purposes in MRI acquisitions. Aqueous Ficoll solutions provide good performance in terms of stability, ease of preparation, and safety.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Ficoll , Imagens de Fantasmas , Humanos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes
9.
J Neuropathol Exp Neurol ; 78(11): 1059-1065, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31559425

RESUMO

The aim of the study was to investigate blood-brain barrier alterations, neuroinflammation, and glial responses in drug abusers. Five immunohistochemical markers (CD3, zonula occludens-1 [ZO-1], intracellular adhesion molecule 1 [ICAM-1], vascular cell adhesion molecule [VCAM-1], and glial fibrillary acidic protein [GFAP]) were assessed on postmortem brain samples collected from drug abusers who died from acute intoxication of cocaine, heroin, or a combination of both, compared with controls. CD3 and ICAM-1 immunopositivity were significantly stronger in drug abusers than in controls. VCAM-1 immunopositivity was similar across drug abuser and control groups. In heroin abusers, significantly lower ZO-1 immunopositivity was observed relative to controls. GFAP positivity did not show significant differences between groups, but its distribution within the brain did differ. Both cocaine and heroin abuse promoted neuroinflammation, increasing expression of ICAM-1 and recruiting CD3+ lymphocytes. Heroin affected the molecular integrity of tight junctions, as reflected by reduced ZO-1 expression. The outcomes of the present study are, overall, consistent with prior available evidence, which is almost exclusively from studies conducted in vitro or in animal models. These findings provide important information about the downstream consequences of neuroinflammation in drug abusers and may help to inform the development of potential therapeutic targets.


Assuntos
Encéfalo/efeitos dos fármacos , Encéfalo/patologia , Transtornos Relacionados ao Uso de Cocaína/patologia , Encefalite/patologia , Dependência de Heroína/patologia , Adolescente , Adulto , Autopsia , Barreira Hematoencefálica/efeitos dos fármacos , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/patologia , Encéfalo/metabolismo , Transtornos Relacionados ao Uso de Cocaína/complicações , Transtornos Relacionados ao Uso de Cocaína/metabolismo , Overdose de Drogas/metabolismo , Overdose de Drogas/patologia , Encefalite/etiologia , Encefalite/metabolismo , Feminino , Dependência de Heroína/complicações , Dependência de Heroína/metabolismo , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Neuroglia/efeitos dos fármacos , Neuroglia/metabolismo , Neuroglia/patologia , Adulto Jovem
10.
Phys Med ; 60: 127-131, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31000072

RESUMO

PURPOSE: To perform a multi-centre survey on the eye lens equivalent dose absorbed by primary interventionalist during catheterization procedures, using a personal dosimeter placed close to the eye lens. METHODS: 15 different cardiologists working in 3 different centers, for a total of 5 operating rooms were enrolled. All of them were provided with a single thermoluminescent dosimeter positioned on the inner side of the temples of eyeglasses. The dose monitoring, performed on a two-months basis, started in 2016 and is still running. All dose measurements were performed by a ISO 17025 standard accredited dosimetry service thus providing certified uncertainties as well. Correlation of eye lens and wrist dose with KAP was also investigated. RESULTS: A total number of 101 eye lens measurements were performed. Annual eye lens dose estimation was obtained for all 15 surgeons (mean, mode, range, standard deviation: 10.8, 8, 4.9-27.3, 5.6  mSv, respectively). Uncertainties on annual eye lens dose estimations ranged between 10% and 20%. No significant correlation was found between eye lens dose and KAP. CONCLUSIONS: Cardiologists involved in catheterization procedures may receive annual eye lens doses close to the ICRP 118 dose limit and thus individual monitoring with a dedicated dosimeter should be carried out. Uncertainty assessment play a relevant role in eye lens equivalent dose estimation to ensure not to exceed dose limit.


Assuntos
Cateterismo , Cristalino , Exposição Ocupacional , Exposição à Radiação , Radiometria/instrumentação , Cirurgiões , Cardiologistas , Cateterismo/efeitos adversos , Desenho de Equipamento , Óculos , Humanos , Cristalino/efeitos da radiação , Proteção Radiológica , Radiometria/métodos , Punho
11.
Phys Med ; 57: 245-250, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30573352

RESUMO

Pre and post-operative exposure levels of medical staff and people from public in intra-operative Ru-106 ophthalmic brachytherapy are reported, together with attenuation properties of selected shielding materials. In particular radiation exposure of workers during plaque transportation and during medical assistance of implanted plaque patient was measured. Taking into account dose rates and considering standard assistance procedure of hospitalized patients, the exposure of medical staff and people of the public were evaluated for a given workload. In order to provide tools to optimize radiation protection, considering social and economic aspects due to possible hospital discharge or hospital stay, the attenuation properties of common shielding materials (lead, concrete, red brick, PMMA and gypsum) were measured, considering both narrow and broad beam setups. The eye was simulated using a water equivalent phantom and plaque was fixed on it. All measurements were performed with calibrated survey meters. Results were compared with numerical simulation of bremsstrahlung X-ray radiation spectra emitted from patient eye. Exposure levels measured at 1 m distance in front of the implanted eye are 0.05 µSv/h/MBq, at 10 cm from patient head, 0.44 µSv/h/MBq (plaque side), 0.4 µSv/h/MBq (front), 0.25 µSv/h/MBq (lateral, opposed to plaque), 0.2 µSv/h/MBq (back). Average exposure levels, under conservative assumptions, for medical staff is 17 µSv/patient and less than 23 µSv/patient for careers and comforters. TVLs in lead and concrete are about 1.6 cm and 11.5 cm respectively.


Assuntos
Braquiterapia/efeitos adversos , Braquiterapia/instrumentação , Neoplasias Oculares/radioterapia , Neoplasias Oculares/cirurgia , Período Pré-Operatório , Proteção Radiológica/instrumentação , Radioisótopos de Rutênio/uso terapêutico , Período Pós-Operatório , Radioisótopos de Rutênio/efeitos adversos
12.
Phys Med ; 54: 49-55, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337010

RESUMO

PURPOSE: The aim of this study was to propose and validate across various clinical scanner systems a straightforward multiparametric quality assurance procedure for proton magnetic resonance spectroscopy (MRS). METHODS: Eighteen clinical 1.5 T and 3 T scanner systems for MRS, from 16 centres and 3 different manufacturers, were enrolled in the study. A standard spherical water phantom was employed by all centres. The acquisition protocol included 3 sets of single (isotropic) voxel (size 20 mm) PRESS acquisitions with unsuppressed water signal and acquisition voxel position at isocenter as well as off-center, repeated 4/5 times within approximately 2 months. Water peak linewidth (LW) and area under the water peak (AP) were estimated. RESULTS: LW values [mean (standard deviation)] were 1.4 (1.0) Hz and 0.8 (0.3) Hz for 3 T and 1.5 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficient of variation of LW and AP for different spatial positions of acquisition voxel were 43% (20%) and 11% (11%), respectively. The mean (standard deviation) phantom T2values were 1145 (50) ms and 1010 (95) ms for 1.5 T and 3 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficients of variation for repeated measurements of LW, AP and T2 were 25% (20%), 10% (14%) and 5% (2%), respectively. CONCLUSIONS: We proposed a straightforward multiparametric and not time consuming quality control protocol for MRS, which can be included in routine and periodic quality assurance procedures. The protocol has been validated and proven to be feasible in a multicentre comparison study of a fairly large number of clinical 1.5 T and 3 T scanner systems.


Assuntos
Espectroscopia de Prótons por Ressonância Magnética/normas , Imagens de Fantasmas , Controle de Qualidade
13.
Phys Med ; 55: 135-141, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30342982

RESUMO

PURPOSE: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0-1000 s/mm2), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. RESULTS: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. CONCLUSION: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single- as well as multi-centre studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Difusão , Imagens de Fantasmas , Controle de Qualidade
14.
J Magn Reson Imaging ; 43(1): 213-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26013043

RESUMO

PURPOSE: To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: Twenty-six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study. Two different DWI acquisition series (b-value ranges 0-1000 and 0-3000 s/mm(2) , respectively) were performed for each MR scanner. All DWI acquisitions were performed by using a cylindrical doped water phantom. Mean apparent diffusion coefficient (ADC) values as well as ADC values along each of the three main orthogonal directions of the diffusion gradients (x, y, and z) were calculated. Short-term repeatability of ADC measurement was evaluated for 26 MR scanners. RESULTS: A good agreement was found between the nominal and measured mean ADC over all the centers. More than 80% of mean ADC measurements were within 5% from the nominal value, and the highest deviation and overall standard deviation were 9.3% and 3.5%, respectively. Short-term repeatability of ADC measurement was found <2.5% for all MR scanners. CONCLUSION: A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI-derived indices before tackling single- as well as multicenter studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Imagem de Difusão por Ressonância Magnética/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Itália , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Magn Reson Imaging ; 29(6): 805-12, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21550742

RESUMO

The purpose of this study was to verify in healthy liver parenchyma the possible influence of age on DwI-related parameters: apparent diffusion coefficient (ADC), perfusion fraction (PF), diffusion and pseudodiffusion coefficient (D and D*). Forty healthy adult volunteers (age range 26-86 years), divided into four age groups, were prospectively submitted to a breath-hold magnetic resonance diffusion imaging (MR-DwI) (two b values, 0-300 and 0-1000 s/mm²). A smaller cohort of 16 subjects underwent a free-breath multi-b acquisition (16 b values, 0-750 s/mm²). Quantitative analysis was performed by two observers with manually defined regions of interest, on the most homogeneous portion of the right liver lobe. Individual and group statistical analysis of data was performed: ANOVA to establish differences between groups and Pearson correlation coefficient to investigate the association between DwI parameters and age. The mean, S.D. and 95% limits of agreement of ADC values for each age-defined group are reported. ANOVA showed no significant differences between group means (P always >.05). No significant correlation between subjects' age and DwI parameters was established, both in breath-hold and free-breath acquisitions, on the whole range of adopted b values. Our study conducted on healthy liver parenchyma shows that there are no significant differences in ADC, PF, D and D* of younger or older subjects.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Fígado/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Análise de Variância , Anisotropia , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
J Magn Reson Imaging ; 31(4): 912-20, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373436

RESUMO

PURPOSE: To compare repeatability and reproducibility of four different methods of apparent diffusion coefficient (ADC) evaluation of liver parenchyma. In fact, repeatability and reproducibility assessment is mandatory in quantitative evaluations, however, these have not been accurately investigated in liver MR-diffusion-weighted studies. MATERIALS AND METHODS: Diffusion-weighted sequences, b-value = 0-1000 s/mm(2), were acquired on 30 healthy volunteers by a 1.5T scanner whose reliability has been validated by a phantom study. Four sampling methods, evaluating various parenchyma percentages by different-sized region-of-interests (ROIs), were compared by two observers: 70% and 30% of the volume, 4%-one-ROI-per-segment, and 4%-one-ROI-per-slice in the right-lobe. Ninety-five percent limits of agreement and intraclass correlation coefficient (ICC) were calculated. RESULTS: Complete measurements on the left lobe could be obtained in less than half of patients. The 4%-one-ROI-per-slice and 4%-one-ROI-per-segment yielded lower mean values compared with 30-70% volume methods (1343-1373 versus 1463-1560.10(-6) mm(2)/s, respectively). Repeatability was acceptable (ICCs approximately 0.80) whereas reproducibility was low (ICCs or=0.87) and reproducibility (ICCs to 0.82) for 30-70% V methods. CONCLUSION: ADC measurements were repeatable but not reproducible in our study. Reproducibility could be improved by taking averages on the right lobe with large ROI methods. Studies on procedures that standardize ADC measurements using more than two observers are needed.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Fígado/patologia , Adulto , Idoso , Feminino , Humanos , Fígado/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Estudos Prospectivos , Controle de Qualidade , Reprodutibilidade dos Testes , Água/química
17.
J Magn Reson Imaging ; 30(5): 1012-20, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19856433

RESUMO

PURPOSE: To improve characterization of focal liver lesions by a prospective quantitative analysis of percentage signal intensity change, in dynamic and late phases after slow (0.5 mL/s) Resovist administration. MATERIALS AND METHODS: Seventy-three patients were submitted on clinical indication to MR examination with Resovist. Signal intensity of 92 detected focal lesions (5-80 mm) were measured with regions of interest and normalized to paravertebral muscle in arterial, portal, equilibrium and T1/T2 late phases, by two observers in conference. Five values of percentage variations per patient were obtained and statistically evaluated. RESULTS: The enhancement obtained on dynamic study is more suitable in hemangiomas and focal nodular hyperplasias than in adenomas and hepatocellular carcinomas. To discriminate benign versus malignant lesions on late-phase-T2-weighted images, a cutoff = -26%, allowed sensitivity and specificity values of 97.4% and 97.7%, respectively. Area under the receiver operating characteristic (ROC) curve was 0.99. To differentiate hemangioma versus all other focal liver lesions, on late-phase-T1-weighted images, a cutoff = +40% permitted sensitivity and specificity values of 90.5% and 98.0%, respectively. Area under the ROC curve was 0.98. CONCLUSION: Late phase quantitative evaluation after slow Resovist administration, allows to differentiate malignant from benign hepatic masses and hemangiomas from all the others focal liver lesions, on T2-/T1-weighted acquisitions, respectively. J


Assuntos
Compostos Férricos/farmacologia , Óxido Ferroso-Férrico/farmacologia , Processamento de Imagem Assistida por Computador/métodos , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacologia , Dextranos , Feminino , Humanos , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
18.
J Magn Reson Imaging ; 30(1): 11-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19557841

RESUMO

PURPOSE: To investigate the impact of cerebrospinal fluid (CSF) contamination on metabolite evaluation in the superior cerebellar vermis with single-voxel (1)H-MRS in normal subjects and patients with degenerative ataxias. MATERIALS AND METHODS: Twenty-nine healthy volunteers and 38 patients with degenerative ataxias and cerebellar atrophy were examined on a 1.5 Tesla scanner. Proton spectra of a volume of interest placed in the superior vermis were acquired using a four TE PRESS technique. We calculated N-acetyl aspartate (NAA)/creatine (Cr), choline (Cho)/Cr, and NAA/Cho ratios, T(2) relaxation times and concentrations of the same metabolites using the external phantom method. Finally, concentrations were corrected taking into account the proportion of nervous tissue and CSF, that was determined as Volume Fraction (VF). RESULTS: In healthy subjects, a significant difference was observed between metabolite concentrations with and without correction for VF. As compared to controls, patients with ataxias showed significantly reduced NAA/Cr and NAA concentrations, while only corrected Cr concentration was significantly increased. The latter showed an inverse correlation with VF. CONCLUSION: CSF contamination has a not negligible effect on the estimation of brain metabolites. The increase of Cr concentration in patients with cerebellar atrophy presumably reflects the substitutive gliosis which takes place along with loss of neurons.


Assuntos
Encéfalo/metabolismo , Ataxia Cerebelar/líquido cefalorraquidiano , Ataxia Cerebelar/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Adulto , Análise de Variância , Ácido Aspártico/análogos & derivados , Ácido Aspártico/líquido cefalorraquidiano , Ácido Aspártico/metabolismo , Encéfalo/patologia , Ataxia Cerebelar/patologia , Cerebelo/metabolismo , Cerebelo/patologia , Colina/líquido cefalorraquidiano , Colina/metabolismo , Creatina/líquido cefalorraquidiano , Creatina/metabolismo , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Imagens de Fantasmas , Reprodutibilidade dos Testes
19.
J Comput Assist Tomogr ; 33(2): 259-65, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19346856

RESUMO

OBJECTIVE: To analyze at computed tomography (CT) examination the "sump effect," a particular type of transient hepatic attenuation differences, related primarily to an increase in arterial flow without any accompanying decrease in portal flow. METHODS: We retrospectively evaluated all biphasic upper abdomen CT examinations (1283 in 807 patients) performed from the year 2003 to the year 2006 and selected and organized those with at least 1 transient hepatic attenuation differences. Of these, we enrolled patients with lobar/multisegmental arterializations surrounding focal lesion(s), without CT portal hypoperfusion signs, in the study group. We assessed histology, number, site, diameter, and volume of causing focal lesion(s); site, extension, and attenuation of arterial area; greater visibility of feeding artery branches ipsilateral to causal focal lesion; and presence of aberrant left hepatic artery. Thirty patients with normal liver represented the control group. RESULTS: Fifteen of the 99 patients with transient hepatic attenuation differences presented with sump effect. In our series, this phenomenon was always related to hypervascular inflammatory and benign lesion(s) with overall average diameter of 8 +/- 4 cm inscribed in arterial area. Attenuation of arterial enhanced areas were significantly higher than the contralateral parenchyma and control patients' parenchyma, with frequent hypertrophy of ipsilateral arterial feeding branches and/or aberrant left hepatic artery visibility. CONCLUSIONS: Siphonage seems to be primary hyperperfusion area determined by arterial bed enlargement, induced by inscribed large hypervascular inflammatory/benign lesion(s).


Assuntos
Hepatopatias/diagnóstico por imagem , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Adulto , Idoso , Feminino , Hemangioma/irrigação sanguínea , Hemangioma/diagnóstico por imagem , Artéria Hepática/diagnóstico por imagem , Humanos , Fígado/patologia , Abscesso Hepático/diagnóstico por imagem , Circulação Hepática , Hepatopatias/patologia , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
20.
J Comput Assist Tomogr ; 32(3): 463-74, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18520558

RESUMO

In magnetic resonance diffusion-weighted imaging, signal intensity is influenced simultaneously by temperature, diffusivity, b value, pseudodiffusion, macroscopic motion, and T2-weighted intensity value. The purpose of this pictorial essay is to discuss and exemplify the influence that such factors and the related modifications have on signal intensity. Apparent diffusion coefficient, shine-through and pseudodiffusion will also be examined to show how T2-weighted signal intensity value and nondiffusional intravoxel incoherent motion can affect the diffusion-weighted imaging.


Assuntos
Imagem de Difusão por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Difusão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...