Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 30(20): 58412-58427, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36991202

RESUMO

The performance of an electrochemically assisted anoxic-oxic membrane bioreactor (A/O-eMBR) was assessed as an alternative for azo dye (Remazol Brilhant Violet (RBV)) removal from simulated textile wastewater. The A/O-eMBR was operated under three experimental conditions (runs I, II, and III), in which different solids retention time (SRT) (45 and 20 d) and exposure mode to electric current (6'ON/30'OFF and 6'ON/12'OFF) were assessed. The reactor exhibited excellent decolorization performance for all runs, with average dye removal efficiency ranging from 94.3 to 98.2%. Activity batch assays showed that the dye removal rate (DRR) decreased from 16.8 to 10.2 mg RBV L-1 h-1 when the SRT was reduced from 45 to 20 d, likely attributed to the lower biomass content under lower sludge age. At the electric current exposure mode of 6' ON/12'OFF, a more substantial decrease of DRR to 1.5 mg RBV L-1 h-1 was noticed, suggesting a possible inhibitory effect on dye removal via biodegradation. By reducing the SRT to 20 d, a worse mixed liquor filterability condition was observed, with a membrane fouling rate (MFR) of 0.979 kPa d-1. In contrast, using the electric current exposure mode of 6'ON/12'OFF resulted in lower membrane fouling propensity, with an MFR of 0.333 kPa d-1. A more attractive cost-benefit ratio for dye removal was obtained using the exposure mode of 6'ON/30'OFF, for which the energy demand was estimated at 21.9-22.6 kWh kg dye-1 removed, almost two times lower than that observed for the mode of 6'ON/12'OFF.


Assuntos
Esgotos , Águas Residuárias , Reatores Biológicos , Eletricidade , Membranas Artificiais , Eliminação de Resíduos Líquidos/métodos
2.
Eng. sanit. ambient ; 24(1): 157-168, jan.-fev. 2019. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1001941

RESUMO

RESUMO O presente estudo avaliou o efeito da idade do lodo (θc) no potencial incrustante do licor misto em um biorreator à membrana (BRM) tratando esgoto sanitário. Tal avaliação foi conduzida em BRM construído em escala de bancada, com volume útil de 15 L, operado por 420 dias na modalidade de batelada sequencial. Durante o período experimental, foram aplicadas 3 estratégias operacionais, E-1, E-2 e E-3, em que foram testadas as idades de lodo de 80, 40 e 20 dias, respectivamente. Os resultados revelaram que a utilização da idade de lodo de 20 dias resultou em licor misto com maior potencial incrustante, apresentando, neste caso, uma velocidade de colmatação (VC) das membranas de 1,95 mbar dia-1, aproximadamente 2 vezes maior do que a observada nas idades de lodo de 80 e 40 dias. A maior colmatação observada foi atribuída a maior concentração de produtos microbianos solúveis (PMSs) no licor misto e a maior relação proteínas/polissacarídeos (PN/PS) dos flocos biológicos nesse período em questão. Por outro lado, a aplicação da idade de lodo de 80 dias resultou em menor VC das membranas do BRM, com valor de 0,82 mbar dia-1. Contudo, no período final dessa estratégia foi observado crescimento excessivo de bactérias filamentosas, que se refletiu em piora da filtrabilidade do licor misto e aumento da VC das membranas. De maneira geral, os resultados obtidos mostraram que a aplicação da idade de lodo de 40 dias resultou em licor misto com menor potencial incrustante.


ABSTRACT This study evaluated the effect of solids retention time (SRT) on membrane fouling rate in a membrane bioreactor (MBR) treating municipal wastewater. The evaluation was conducted in a membrane bioreactor built in bench scale, with a volume of 15 L, operated for 420 days in the sequential batch regime. During this period, three experimental runs were applied, E-1, E-2 and E-3, in which the solids retention time of 80, 40 and 20 days, respectively, were tested. The results showed that use of 20-days solids retention time resulted in a higher membrane fouling rate (MFR), with value of 1,95 mbar d-1, approximately two times higher than observed in the solids retention time of 80 and 40 days. The higher membrane fouling rate observed was attributed to a higher concentration of soluble microbial products (SMP) in the mixed liquor and to the higher proteins/polysaccharides ratio of the biological flocs in this period. On the other hand, the use of 80-days solids retention time resulted in a lower membrane fouling rate, with a value of 0.82 mbar d-1. However, it was observed in the final period of this experimental run an excessive growth of filamentous bacteria, which was reflected in a deterioration of the mixed liquor filterability and an increase of membrane fouling rate. Overall, the results showed that the 40-days solids retention time resulted in a mixed liquor with lower fouling propensity.

3.
Environ Sci Pollut Res Int ; 25(32): 32767-32782, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30251038

RESUMO

A sequencing batch conventional membrane bioreactor (SB-CMBR) and sequencing batch hybrid membrane bioreactor (SB-HMBR) were operated in parallel under two different hydraulic retention times (HRTs) (namely 12 h and 6 h), and their chemical oxygen demand (COD) and nutrient removal performance, membrane fouling behavior, and microbial community characteristics were compared. Both systems exhibited high organic matter (> 95%) and ammonium (> 98%) removal performance regardless of the HRT applied. As the HRT was reduced from 12 to 6 h, total nitrogen removal slightly increased in both reactors, being higher in the carrier-based MBR, where anoxic zones may have been established within the biofilm. Conversely, total phosphorus removal improved only in the SB-CMBR at the shorter HRT. Moreover, activity batch assays have shown a faster P uptake rate in the SB-CMBR than in the SB-HMBR, a result likely associated with the lower relative abundance of phosphate-accumulating organisms in both adhered and suspended biomass fractions in the hybrid MBR. The results also revealed that more pronounced increases in the transmembrane pressure and, consequently, in the membrane fouling rate at higher COD loading rates were observed in the SB-CMBR, where the soluble microbial products (proteins, polysaccharides, and especially, transparent exopolymer particles), supernatant turbidity, and filamentous bacteria were more significant. Overall, as compared to the conventional MBR, the plastic media-based SB-HMBR showed a lower fouling propensity at all hydraulic conditions tested.


Assuntos
Reatores Biológicos/microbiologia , Membranas Artificiais , Microbiota , Eliminação de Resíduos Líquidos/métodos , Compostos de Amônio , Bactérias , Biofilmes , Análise da Demanda Biológica de Oxigênio , Biomassa , Nitrogênio , Fósforo , Águas Residuárias/microbiologia
4.
Water Sci Technol ; 78(11): 2364-2373, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30699088

RESUMO

This study evaluated the effects of electrochemical processes on the mixed liquor characteristics of an electro-membrane bioreactor (e-MBR) applied to municipal wastewater treatment. A laboratory-scale e-MBR was assessed under two experimental runs: without the electric field (run I) and with electric field, controlled by the application of an electric current set in 10.0 A m-2 under intermittent exposure mode of 6 minutes ON/18 minutes OFF (run II). The electric field caused approximately 55% removal of both soluble microbial products (SMP) and extracellular polymeric substances (EPS), whereas the proteins/carbohydrates ratio in EPS was increased from 1.9 in the run I to 2.9 in run II, leading to an increment of flocs' hydrophobicity. Additionally, the sludge floc size average value was reduced from 42.2 µm in run I to 24.6 µm in run II, which led to a significant enhancement in the sludge settleability. As a result, the membrane fouling rate was always less than 3.80 mbar d-1 in run II, whereas in run I these values reached up to 34.7 mbar d-1. These results demonstrated that the electrochemical processes enhanced the mixed liquor filterability. Therefore, their implementation represents a great alternative to improve the operational stability of membrane bioreactors.


Assuntos
Reatores Biológicos , Membranas Artificiais , Eliminação de Resíduos Líquidos/métodos , Esgotos , Águas Residuárias
5.
Environ Technol ; 38(7): 806-815, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27408986

RESUMO

This study evaluated the removal of organic matter, nitrogen and phosphate from a municipal wastewater in a sequencing batch membrane bioreactor (SBMBR) operated at different solids retention times (SRTs) and subjected to different aeration profiles. The results demonstrated that SRT reduction from 80 to 20 d had a negligible effect on chemical oxygen demand (COD) removal and only a slight negative effect on nitrification. COD removal efficiency remained stable at 97%, whereas ammonium removal decreased from 99% to 97%. The total nitrogen removal efficiency was improved by SRT reduction, increasing from 80% to 86%. Although the total phosphorus (TP) removal was not significantly affected by the SRT reduction, ranging from 40-49%, the P-release and P-uptake processes were observed to increase as the SRT was reduced. The implementation of a pre-aeration phase in the SBMBR operating cycle allowed a higher TP removal performance, which reached up to 76%. Batch tests suggested that the fraction of phosphate removed anoxically from the total (anoxic + aerobic) phosphate removal decreased with the SRT reduction.


Assuntos
Nitrogênio/isolamento & purificação , Fósforo/isolamento & purificação , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Reatores Biológicos/microbiologia
6.
Eng. sanit. ambient ; 17(2): 143-154, abr.-jun. 2012. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-665939

RESUMO

Neste trabalho, avaliou-se o desempenho de um biorreator à membrana em batelada sequencial para a remoção de nutrientes (nitrogênio e fósforo) de esgoto sanitário. O reator, construído em escala piloto, foi operado durante 241 dias com tempo total de ciclo de 4 horas, sendo 5 minutos para alimentação, 55 minutos para a fase anóxica e 180 minutos para as fases de aeração e filtração (simultaneamente). Ao longo do monitoramento, foram empregados dois fluxos de filtração: 5,55 e 11,1 L.m-2.h-1, que resultaram nas taxas de troca volumétrica de 5 e 10%, respectivamente. As eficiências médias de remoção de Demanda Química de Oxigênio total, nitrogênio amoniacal e nitrogênio total alcançadas foram de 99, 98 e 96%, respectivamente. Em relação à remoção de fósforo, observou-se inicialmente um baixo rendimento do reator, sendo verificado ao longo do tempo, no entanto, uma tendência de melhora na remoção desse nutriente, atingindo eficiência média de 74% entre os dias 158 e 241. A utilização do fluxo de filtração de 5,55 L.m-2.h-1 proporcionou uma operação estável ao biorreator à membrana em batelada sequencial no que se refere à pressão transmembrana, tendo sido atingido o valor limite de 0,7 bar apenas uma vez em 181 dias de operação, ao passo que, com fluxo de 11,1 L.m-2.h-1, esse limite foi atingido 3 vezes em 55 dias.


This study evaluated the performance of a membrane bioreactor sequencing batch, in pilot scale, to remove nutrients (nitrogen and phosphorus) from domestic wastewater. The reactor was operated for 241 days with a total cycle time of 4 hours, with 5 minutes for feeding, 55 minutes for the anoxic phase and 180 minutes for the aeration and filtration phases (simultaneously). Throughout the monitoring, two filtration flows were employed: 5.5 and 11.1 (critical flux) L.m-2.h-1, which resulted in the volume exchange rates of 5 and 10%, respectively. The removal efficiencies of total Chemical Oxygen Demand, ammonia nitrogen and total nitrogen were achieved by 99, 98 and 96%, respectively. Regarding phosphorus removal, a poor performance was observed in the beginning of the experiment; however, a tendency of improvement in the removal of this nutrient was further verified, reaching an efficiency average of 74% between the operational days 158 and 241. The flux filtration at 5.55 L.m-2.h-1 has provided a membrane bioreactor sequencing batch stable operation in relation to transmembrane pressure since it reached the limit value of 0.7 bar only once in 181 operational days, while for 11.1 L.m-2.h-1 it was observed 3 times in 55 days.