Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 98(4): 723-732, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34164905

RESUMO

OBJECTIVES: To investigate the long-term vasomotor response and inflammatory changes in Absorb bioresorbable vascular scaffold (BVS) and metallic drug-eluting stent (DES) implanted artery. BACKGROUND: Clinical evidence has demonstrated that compared to DES, BVS is associated with higher rates of target lesion failure. However, it is not known whether the higher event rates observed with BVS are related to endothelial dysfunction or inflammation associated with polymer degradation. METHODS: Ten Absorb BVS and six Xience V DES were randomly implanted in the main coronaries of six nonatherosclerotic swine. At 4-years, vasomotor response was evaluated in vivo by quantitative coronary angiography response to intracoronary infusion of Ach and ex vivo by the biomechanical response to prostaglandin F2-α (PGF2-α), substance P and bradykinin and gene expression analysis. RESULTS: Absorb BVS implanted arteries showed significantly restored vasoconstrictive responses after Ach compared to in-stent Xience V. The contractility of Absorb BVS treated segments induced by PGF2-α was significantly greater compared to Xience V treated segments and endothelial-dependent vasorelaxation was greater with Absorb BVS compared to Xience V. Gene expression analyses indicated the pro-inflammatory lymphotoxin-beta receptor (LTßR) signaling pathway was significantly upregulated in arteries treated with a metallic stent compared to Absorb BVS treated arterial segments. CONCLUSIONS: At 4 years, arteries treated with Absorb BVS compared with Xience V, demonstrate significantly greater restoration of vasomotor responses. Genetic analysis suggests mechanobiologic reparation of Absorb BVS treated arteries at 4 years as opposed to Xience V treated vessels.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Animais , Everolimo , Expressão Gênica , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Stents , Suínos , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 9(7): 728-41, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27056313

RESUMO

OBJECTIVES: The purpose of this study was to assess and compare in vivo the restoration of vasomotor function following Absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) and metallic Xience V (XV) (Abbott Vascular, Santa Clara, California) stent implantations in porcine coronary arteries at 1 and 2 years. BACKGROUND: Drug-eluting metallic coronary stents induce sustained vasomotor dysfunction, and preliminary observations from arteries with bioresorbable scaffolds have indicated partially restored vasoreactivity. METHODS: A total of 15 Absorb BVS (3.0 × 18.0 mm) and 14 XV (3.0 × 18.0 mm or 3.0 × 12.0 mm) stents were randomly implanted in the main coronaries of 12 nonatherosclerotic swine. The effect of implant on vasomotor performance (constrictive and expansive) was measured in the stented/scaffolded segments and the 5-mm proximal and distal adjacent segments in vivo by angiography assessing mean luminal diameter changes following infusion of vasoactive agents at 1 year (n = 6) and 2 years (n = 6) as well as ex vivo at 2 years using a tissue chamber apparatus. Endothelial cell function and smooth muscle cell phenotype gene marker levels were evaluated with quantitative real-time polymerase chain reaction. RESULTS: The scaffolded Absorb BVS segments showed fully restored constrictive response compared with XV implanted vessels at 1 year: -24.30 ± 14.31% versus -1.79 ± 6.57% (p < 0.004) and at 2 years: -28.13 ± 14.60% versus -3.90 ± 6.44% (p < 0.004). The early restoration of vasomotor function within the scaffolded segments reached a peak at 1 year and did not significantly change up to 2 years. The vasoactive responses of Absorb BVS-implanted vessels within the scaffolded segments were similar to those observed within the proximal and distal edge segments at both time points. Conversely, the stented XV segments demonstrated significantly impaired constrictive response compared with the distal XV edges at 1 year: -1.79 ± 6.57% versus -21.89 ± 7.17% (p < 0.0002) and at 2 years: -3.90 ± 6.44% versus -21.93 ± 15.60% (p < 0.03). Ex vivo assessment of contraction induced by PGF2α and relaxation induced by substance P of isolated BVS segments compared with XV-treated segments generated greater contraction force of 3.94 ± 0.97 g versus 1.83 ± 1.03 g (p < 0.05), and endothelial-dependent relaxation reached 35.91 ± 24.74% versus 1.20 ± 3.79% (p < 0.01). Quantitative real-time polymerase chain reaction gene analysis at 2 years demonstrated increased Connexin 43 messenger ribonucleic acid levels of Absorb BVS-treated vessels compared with XV-treated vessels: 1.92 ± 0.23 versus 0.77 ± 12 (p < 0.05). CONCLUSIONS: Absorb BVS-implanted coronary arteries demonstrate early functional restoration of the scaffolded and adjacent segments at 1 year, which is preserved up to 2 years.


Assuntos
Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Intervenção Coronária Percutânea/instrumentação , Vasoconstrição/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Animais , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/metabolismo , Vasos Coronários/fisiopatologia , Regulação da Expressão Gênica , Técnicas In Vitro , Modelos Animais , Intervenção Coronária Percutânea/efeitos adversos , Fenótipo , Reação em Cadeia da Polimerase em Tempo Real , Recuperação de Função Fisiológica , Suínos , Porco Miniatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...