Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 187(12): 638, 2020 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-33146855

RESUMO

A room temperature benzene and formaldehyde gas sensor system with an ionogel as sensing material is presented. The sensing layer is fabricated employing poly(N-isopropylacrylamide) polymerized in the presence of 1-ethyl-3-methylimidazolium ethyl sulfate ionic liquid onto gold interdigitated electrodes. When the ionogel is exposed to increasing formaldehyde concentrations employing N2 as a carrier gas, a more stable response is observed in comparison to the bare ionic liquid, but no difference in sensitivity occurs. On the other hand, when air is used as carrier gas the sensitivity of the system towards formaldehyde is decreased by one order of magnitude. At room temperature, the proposed sensor exhibited in air higher sensitivities to benzene, at concentrations ranging between 4 and 20 ppm resulting, in a limit of detection of 47 ppb, which is below the standard permitted concentrations. The selectivity of the IL towards HCHO and C6H6 is demonstrated by the absence of response when another IL is employed. Humidity from the ambient air slightly affects the resistance of the system proving the protective role of the polymeric matrix. Furthermore, the gas sensor system showed fast response/recovery times considering the thickness of the material, suggesting that ionogel materials can be used as novel and highly efficient volatile organic compounds sensors operating at room temperature.Graphical abstract.


Assuntos
Benzeno/análise , Formaldeído/análise , Géis/química , Imidazóis/química , Temperatura , Resinas Acrílicas/química , Eletrodos , Limite de Detecção , Compostos Orgânicos Voláteis/análise
2.
Int J Pharm ; 560: 65-77, 2019 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-30742984

RESUMO

Microencapsulation of pancreatic islets for the treatment of Type I Diabetes Mellitus (T1DM) generates a high quantity of empty microcapsules, resulting in high therapeutic graft volumes that can enhance the host's immune response. We report a 3D printed microfluidic magnetic sorting device for microcapsules purification with the objective to reduce the number of empty microcapsules prior transplantation. In this study, INS1E pseudoislets were microencapsulated within alginate (A) and alginate-poly-L-lysine-alginate (APA) microcapsules and purified through the microfluidic device. APA microcapsules demonstrated higher mechanical integrity and stability than A microcapsules, showing better pseudoislets viability and biological function. Importantly, we obtained a reduction of the graft volume of 77.5% for A microcapsules and 78.6% for APA microcapsules. After subcutaneous implantation of induced diabetic Wistar rats with magnetically purified APA microencapsulated pseudoislets, blood glucose levels were restored into normoglycemia (<200 mg/dL) for almost 17 weeks. In conclusion, our described microfluidic magnetic sorting device represents a great alternative approach for the graft volume reduction of microencapsulated pseudoislets and its application in T1DM disease.


Assuntos
Diabetes Mellitus Experimental/terapia , Diabetes Mellitus Tipo 1/terapia , Transplante das Ilhotas Pancreáticas/métodos , Dispositivos Lab-On-A-Chip , Alginatos/química , Animais , Glicemia/metabolismo , Cápsulas , Composição de Medicamentos , Magnetismo , Masculino , Polilisina/análogos & derivados , Polilisina/química , Ratos , Ratos Wistar , Resultado do Tratamento
3.
Biomicrofluidics ; 9(4): 044124, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26339323

RESUMO

This paper reports an innovative technique for reagents storage in microfluidic devices by means of a one-step UV-photoprintable ionogel-based microarray on non-modified polymeric substrates. Although the ionogel and the ink-jet printing technology are well published, this is the first study where both are used for long-term reagent storage in lab-on-a-chip devices. This technology for reagent storage is perfectly compatible with mass production fabrication processes since pre-treatment of the device substrate is not necessary and inkjet printing allows for an efficient reagent deposition process. The functionality of this microarray is demonstrated by testing the release of biotin-647 after being stored for 1 month at room temperature. Analysis of the fluorescence of the ionogel-based microarray that contains biotin-647 demonstrated that 90% of the biotin-647 present was released from the ionogel-based microarray after pumping PBS 0.1% Tween at 37 °C. Moreover, the activity of biotin-647 after being released from the ionogel-based microarray was investigated trough the binding capability of this biotin to a microcontact printed chip surface with avidin. These findings pave the way for a novel, one-step, cheap and mass production on-chip reagents storage method applicable to other reagents such as antibodies and proteins and enzymes.

4.
Anal Bioanal Chem ; 404(10): 2851-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22895739

RESUMO

A portable instrument for oxygen determination, based on the quenching of phosphorescent octaethylporphyrin by gaseous O(2), has been developed using the fluorimetric paired emitter-detector diode technique (FPEDD). The instrument configuration consists of two light-emitting diodes (LEDs) facing each other, with an interchangeable support containing a phosphorescent membrane in between, in which one of the LEDs is used as the light source (emitter LED) and the other, working in reverse bias mode, as the light detector. The feasibility of using a LED as a luminescence detector is studied. Its small size enables integration of the instrument into a portable measurement system. A systematic study of the system capabilities as a portable instrument was performed to optimize range, sensitivity, short term and long term stability, dynamic behaviour, effect of temperature and humidity, and temporal drift.

5.
Anal Chim Acta ; 699(2): 216-22, 2011 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-21704777

RESUMO

A new system for CO(2) measurement (0-100%) based on a paired emitter-detector diode arrangement as a colorimetric detection system is described. Two different configurations were tested: configuration 1 (an opposite side configuration) where a secondary inner-filter effect accounts for CO(2) sensitivity. This configuration involves the absorption of the phosphorescence emitted from a CO(2)-insensitive luminophore by an acid-base indicator and configuration 2 wherein the membrane containing the luminophore is removed, simplifying the sensing membrane that now only contains the acid-base indicator. In addition, two different instrumental configurations have been studied, using a paired emitter-detector diode system, consisting of two LEDs wherein one is used as the light source (emitter) and the other is used in reverse bias mode as the light detector. The first configuration uses a green LED as emitter and a red LED as detector, whereas in the second case two identical red LEDs are used as emitter and detector. The system was characterised in terms of sensitivity, dynamic response, reproducibility, stability and temperature influence. We found that configuration 2 presented a better CO(2) response in terms of sensitivity.


Assuntos
Dióxido de Carbono/análise , Colorimetria/métodos , Gases/química , Colorimetria/instrumentação , Luz
6.
Lab Chip ; 7(10): 1345-51, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17896020

RESUMO

The esterification reaction of phthalic anhydride with methanol was performed at different temperatures in a continuous flow glass microreactor at pressures up to 110 bar and using supercritical CO(2) as a co-solvent. The design is such that supercritical CO(2) can be generated inside the microreactor. Substantial rate enhancements were obtained, viz. a 53-fold increase was obtained at 110 bar and 60 degrees C. Supercritical CO(2) as a co-solvent gave rise to a 5400-fold increase (both with respect to batch experiments at 1 bar at the same temperature).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...