Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732996

RESUMO

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

2.
Rev Sci Instrum ; 92(1): 013103, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514202

RESUMO

We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron x-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of 4 eV at 6 keV at a rate of ∼1 c/s pixel-1. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of ∼2 × 103 c/s (all pixels) with an energy resolution of 5 eV at 6 keV. By utilizing the TES's wideband spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted x-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As Kα and Pb Lα2 of the standard sample were clearly resolved, and the XANES of Pb Lα2 was obtained. Moreover, the x-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard x-ray synchrotron facilities.

3.
Artigo em Inglês | MEDLINE | ID: mdl-35529769

RESUMO

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of ∼ 1 µm. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

4.
Appl Phys Lett ; 118(20)2021.
Artigo em Inglês | MEDLINE | ID: mdl-37056739

RESUMO

Transition-edge sensors (TESs) are two-dimensional superconducting films utilized as highly sensitive detectors of energy or power. These detectors are voltage biased in the superconducting-normal transition where the film resistance is both finite and a strong function of temperature. Unfortunately, the amount of electrical noise observed in TESs exceeds the predictions of existing noise theories. We describe a possible mechanism for the unexplained excess noise, which we term "mixed-down noise." The source is Johnson noise, which is mixed down to low frequencies by Josephson oscillations in devices with a nonlinear current-voltage relationship. We derive an expression for the power spectral density of this noise and show that its predictions agree with measured data.

5.
Rev Sci Instrum ; 90(11): 113101, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779391

RESUMO

We present results obtained with a new soft X-ray spectrometer based on transition-edge sensors (TESs) composed of Mo/Cu bilayers coupled to bismuth absorbers. This spectrometer simultaneously provides excellent energy resolution, high detection efficiency, and broadband spectral coverage. The new spectrometer is optimized for incident X-ray energies below 2 keV. Each pixel serves as both a highly sensitive calorimeter and an X-ray absorber with near unity quantum efficiency. We have commissioned this 240-pixel TES spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) and used it to probe the local electronic structure of sample materials with unprecedented sensitivity in the soft X-ray regime. As mounted, the TES spectrometer has a maximum detection solid angle of 2 × 10-3 sr. The energy resolution of all pixels combined is 1.5 eV full width at half maximum at 500 eV. We describe the performance of the TES spectrometer in terms of its energy resolution and count-rate capability and demonstrate its utility as a high throughput detector for synchrotron-based X-ray spectroscopy. Results from initial X-ray emission spectroscopy and resonant inelastic X-ray scattering experiments obtained with the spectrometer are presented.

6.
J Astron Telesc Instrum Syst ; 5(2): 021017, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33442556

RESUMO

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx's three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 m2 of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

7.
Artigo em Inglês | MEDLINE | ID: mdl-33456289

RESUMO

We are designing an array of transition-edge sensor (TES) microcalorimeters for a soft X-ray spectrometer at the Linac Coherent Light Source at SLAC National Accelerator Laboratory to coincide with upgrades to the free electron laser facility. The complete spectrometer will have 1000 TES pixels with energy resolution of 0.5 eV full-width at half-maximum (FWHM) for incident energies below 1 keV while maintaining pulse decay-time constants shorter than 100 µs. Historically, TES pixels have often been designed for a particular scientific application via a combination of simple scaling relations and trial-and-error experimentation with device geometry. We have improved upon this process by using our understanding of transition physics to guide TES design. Using the two-fluid approximation of the phase-slip line model for TES resistance, we determine how the geometry and critical temperature of a TES will affect the shape of the transition. We have used these techniques to design sensors with a critical temperature of 55 mK. The best sensors achieve an energy resolution of 0.75 eV FWHM at 1.25 keV. Building upon this result, we show how the next generation of sensors can be designed to reach our goal of 0.5 eV resolution.

8.
Anal Chem ; 87(7): 3996-4000, 2015 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-25723106

RESUMO

We have developed a new category of sensor for measurement of the (240)Pu/(239)Pu mass ratio from aqueous solution samples with advantages over existing methods. Aqueous solution plutonium samples were evaporated and encapsulated inside of a gold foil absorber, and a superconducting transition-edge-sensor microcalorimeter detector was used to measure the total reaction energy (Q-value) of nuclear decays via heat generated when the energy is thermalized. Since all of the decay energy is contained in the absorber, we measure a single spectral peak for each isotope, resulting in a simple spectral analysis problem with minimal peak overlap. We found that mechanical kneading of the absorber dramatically improves spectral quality by reducing the size of radioactive inclusions within the absorber to scales below 50 nm such that decay products primarily interact with atoms of the host material. Due to the low noise performance of the microcalorimeter detector, energy resolution values of 1 keV fwhm (full width at half-maximum) at 5.5 MeV have been achieved, an order of magnitude improvement over α-spectroscopy with conventional silicon detectors. We measured the (240)Pu/(239)Pu mass ratio of two samples and confirmed the results by comparison to mass spectrometry values. These results have implications for future measurements of trace samples of nuclear material.

9.
J Am Acad Orthop Surg ; 23(1): 7-17, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25538126

RESUMO

Orthopaedic surgeons frequently treat patients who report pain that radiates from the back into the lower extremity. Although the most common etiology is either a herniated disk or spinal stenosis, a myriad of pathologies can mimic the symptoms of radiculopathy, resulting in differences in the clinical presentation and the workup. Therefore, the clinician must be able to distinguish the signs and symptoms of lumbar radiculopathy from pathologies that may have a similar presentation. Being cognizant of these other possible conditions enables the physician to consider a breadth of alternative diagnoses when a patient presents with radiating lower extremity pain.


Assuntos
Radiculopatia/diagnóstico , Radiculopatia/etiologia , Neuropatias Diabéticas/complicações , Neuropatias Diabéticas/diagnóstico , Diagnóstico Diferencial , Impacto Femoroacetabular/complicações , Impacto Femoroacetabular/diagnóstico , Humanos , Deslocamento do Disco Intervertebral/complicações , Vértebras Lombares/lesões , Imageamento por Ressonância Magnética , Mielite/diagnóstico , Osteoartrite do Quadril/complicações , Osteoartrite do Quadril/diagnóstico , Neuropatias Fibulares/diagnóstico , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/diagnóstico , Estenose Espinal/diagnóstico
10.
Rev Sci Instrum ; 84(1): 014706, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23387678

RESUMO

Careful filtering is necessary for observations of quantum phenomena in superconducting circuits at low temperatures. Measurements of coherence between quantum states require extensive filtering to protect against noise coupled from room temperature electronics. We demonstrate distributed transmission line filters which cut off exponentially at GHz frequencies and can be anchored at the base temperature of a dilution refrigerator. The compact design makes them suitable to filter many different bias lines in the same setup, necessary for the control and measurement of superconducting qubits.

11.
J Hazard Mater ; 181(1-3): 121-6, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20510513

RESUMO

Biochar is a carbon-rich product generated from biomass through pyrolysis. This study evaluated the ability of an unmodified biochar to sorb two triazine pesticides - atrazine and simazine, and thereby explored potential environmental values of biochar on mitigating pesticide pollution in agricultural production and removing contaminants from wastewater. A greenwaste biochar was produced by heating waste biomass under the oxygen-limited condition at 450 degrees C. The effects of several experimental parameters, including biochar particle size, contact time, solid/solution ratio, and solution pH on the sorption of atrazine and simazine were comprehensively investigated. The biochar with small particle size needed less time to reach sorption equilibrium. The sorption affinity of the biochar for the two pesticides increased with decreasing solid/solution ratio. The sorbed amounts (C(s)) of atrazine and simazine increased from 451 to 1158 mg/kg and 243 to 1066 mg/kg, respectively, when the solid/solution ratio decreased from 1:50 to 1:1000 (g/mL). The sorption of the biochar for both pesticides was favored by low pH. The sorption isotherms of atrazine and simazine on the biochar are nonlinear and follow a Freundlich model. When atrazine and simazine co-existed, a competitive sorption occurred between these two pesticides on the biochar, reflecting a decrease in sorption capacity (K(f)) from 435 to 286 for atrazine and from 514 to 212 for simazine. Combined adsorption and partition mechanisms well depicted sorption of atrazine and simazine on carbonized and noncarbonized fractions of the biochar in the single-solute and co-solute systems.


Assuntos
Carvão Vegetal/química , Praguicidas/isolamento & purificação , Triazinas/isolamento & purificação , Adsorção , Atrazina/isolamento & purificação , Simazina/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação
12.
Clin Biomech (Bristol, Avon) ; 23(9): 1165-71, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18599168

RESUMO

BACKGROUND: Eccentric quadriceps contraction during landing and the resulting anterior tibial shear force are anterior cruciate ligament injury risk factors, while hamstring contraction limits anterior cruciate ligament loading. Anterior tibial shear force is derived from quadriceps and hamstring co-contraction, and a greater quadriceps/hamstring strength ratio has been associated with heightened lower extremity injury risk. The purpose of this investigation was to evaluate relationships between anterior tibial shear force during landing and quadriceps and hamstring strength. METHODS: Anterior tibial shear force was calculated during a jump landing task in 26 healthy females. Isokinetic eccentric quadriceps strength and concentric hamstrings strength were assessed at 60 degrees /s, 180 degrees /s, and 300 degrees /s. Correlational analyses were conducted to evaluate relationships between lower extremity strength and anterior tibial shear force. FINDINGS: Quadriceps (r=0.126 to 0.302, P>0.05) and hamstrings strength (r=-0.019 to 0.058, P>0.05) and the quadriceps/hamstring ratio (r=0.036 to 0.127, P>0.05) were not significant predictors of anterior tibial shear force. INTERPRETATION: Quadriceps and hamstring strength are not indicative of sagittal-plane knee loading during landing. Contractile force resulting from maximal strength testing may not represent that produced during landing, as it is unlikely that landing requires maximal effort. Additionally, peak anterior tibial shear force, quadriceps torque, and hamstrings torque are generated at different points in the knee flexion/extension range of motion. Therefore, peak anterior tibial shear force is a function of the available strength at a given point in the range of motion rather than of peak strength. These findings illustrate the limitations of peak strength values in predicting dynamic loading during landing.


Assuntos
Articulação do Joelho/fisiologia , Locomoção/fisiologia , Modelos Biológicos , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Esforço Físico/fisiologia , Tíbia/fisiologia , Simulação por Computador , Feminino , Humanos , Equilíbrio Postural/fisiologia , Resistência ao Cisalhamento , Análise e Desempenho de Tarefas , Adulto Jovem
18.
Ment Health (Lond) ; 30(Spring): 36-37, 1971.
Artigo em Inglês | MEDLINE | ID: mdl-28908737

RESUMO

An examination of a report published by the Psychiatric Rehabilitation Association.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...