Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pract Lab Med ; 39: e00357, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38404528

RESUMO

Objective: To compare the laboratory tests conducted in real-life settings for patients with anemia with the expected prescriptions derived from an optimal checkup. Methods: A panel of experts formulated an "optimal laboratory test assessment" specific to each anemia profile. A retrospective analysis was done of the laboratory tests conducted according to the type of anemia (microcytic, normocytic or macrocytic). Using an algorithmic system, the laboratory tests performed in real-life practice were compared with the recommendations suggested in the "optimal laboratory test assessment" and with seemingly "unnecessary" laboratory tests. Results: In the analysis of the "optimal laboratory test assessment", of the 1179 patients with microcytic anemia, 269 (22.8%) had had one of the three tests recommended by the expert system, and only 33 (2.8%) had all three tests. For normocytic anemia, 1054 of 2313 patients (45.6%) had one of the eleven recommended tests, and none had all eleven. Of the 384 patients with macrocytic anemia, 196 (51%) had one of the four recommended tests, and none had all four. In the analysis of "unnecessary laboratory tests", one lab test was unnecessarily done in 727/3876 patients (18.8%), i.e. 339 of 1179 (28.8%) microcytic, 171 of 2313 (7.4%) normocytic, and 217 of 384 (56.5 %) macrocytic anemias. Conclusion: Laboratory investigations of anemia remain imperfect as more than half of the cases did not receive the expected tests. Analyzing other diagnostic domains, the authors are currently developing an artificial intelligence system to assist physicians in enhancing the efficiency of their laboratory test prescriptions.

2.
Ann Vasc Surg ; 48: 141-150, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29225128

RESUMO

BACKGROUND: Technical and clinical success of thoracic aortic endovascular procedures relies mainly on the choice of the proximal sealing zone (PSZ). The latter can be affected by multiple complications, all of them having a potential gravity and a direct link with the quality of the PSZ. The objective of this study was to analyze the risk factors of PSZ complications occurrence. METHODS: Between 2007 and 2015, all the patients treated by a thoracic stent graft in zones 2, 3, or 4 were retrospectively reviewed, with analysis of the preoperative and postoperative angio-computed tomography. Proximal sealing zone complications are type Ia endoleaks, bird beak ≥20 mm, malposition ≥11 mm, migration ≥10 mm, and retrograde dissection. Three types of potential risk factors were analyzed: (1) related to the patients (age, gender, pathology, urgency, hybrid surgery); (2) related to the stent graft (bare or covered proximal stent, degree of oversizing, number of stents, generation); (3) related to the morphology (radius of curvature, diameter, degree of conicity, calcifications and thrombus of the neck, depth of the arch, angulation of the proximal sealing zone, and tortuosity index of the arch and the thoracic aorta. RESULTS: Seventy-six patients (mean age: 54 years, 17-93 years) were treated for traumatic aortic rupture (n = 27, 35.5%), aortic dissection (n = 26, 34%), aneurysm (n = 15, 20%), and other diseases (floating thrombus, aortoesophageal fistula) (n = 8, 10.5%). A hybrid surgery was carried out in 18 patients (24%). Primary technical success was 93.5% (n = 71). With a mean follow-up of 29 months, 30 PSZ complications were observed in 21 patients (28%): type Ia endoleaks (n = 3, 4%), bird beak (n = 7, 9%), malposition (n = 3, 4%), migration (n = 1, 1.5%), retrograde dissection (n = 1, 1.5%), or several complications (n = 6, 7.8%). Among the morphological factors, 2 parameters were significantly associated with the occurrence of complications: tortuosity index (group without PSZ complications 1.62 ± 0.2 vs. group with PSZ complications 1.72 ± 0.2, P = 0.042), and the diameter of the proximal neck (group without PSZ complications 25.7 ± 5 vs. group with PSZ complications 31 ± 6.0, P = 0.001). Neither the demographic factors nor those related to the stent graft presented a statistically significant relation with the occurrence of complications. CONCLUSIONS: This work clearly highlights the relation between PSZ complications, independently of their type, and the local and global aortic morphology. A wide proximal neck, > 34 mm, and an important aortic tortuosity, > 1.8, are situations at risk.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/lesões , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Feminino , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...