Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PRX quantum ; 3(1)2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36726390

RESUMO

Scaling of quantum computers to fault-tolerant levels relies critically on the integration of energy-efficient, stable, and reproducible qubit control and readout electronics. In comparison to traditional semiconductor-control electronics (TSCE) located at room temperature, the signals generated by rf sources based on Josephson-junctions (JJs) benefit from small device sizes, low power dissipation, intrinsic calibration, superior reproducibility, and insensitivity to ambient fluctuations. Previous experiments to colocate qubits and JJ-based control electronics have resulted in quasiparticle poisoning of the qubit, degrading the coherence and lifetime of the qubit. In this paper, we digitally control a 0.01-K transmon qubit with pulses from a Josephson pulse generator (JPG) located at the 3-K stage of a dilution refrigerator. We directly compare the qubit lifetime T 1, the coherence time T 2 * , and the thermal occupation P th when the qubit is controlled by the JPG circuit versus the TSCE setup. We find agreement to within the daily fluctuations of ±0.5 µs and ±2 µs for T 1 and T 2 * , respectively, and agreement to within the 1% error for P th. Additionally, we perform randomized benchmarking to measure an average JPG gate error of 2.1 × 10-2. In combination with a small device size (< 25 mm2) and low on-chip power dissipation (≪100 µW), these results are an important step toward demonstrating the viability of using JJ-based control electronics located at temperature stages higher than the mixing-chamber stage in highly scaled superconducting quantum information systems.

2.
Meas Sci Technol ; 30(11)2019.
Artigo em Inglês | MEDLINE | ID: mdl-38915953

RESUMO

Johnson noise thermometers infer thermodynamic temperature from measurements of the thermally-induced current fluctuations that occur in all electrical conductors. This paper reviews the status of Johnson noise thermometry and its prospects for both metrological measurements and for practical applications in industry. The review begins with a brief description of the foundations and principles of Johnson noise thermometry before outlining the many different techniques and technological breakthroughs that have enabled the application of JNT to high-accuracy, cryogenic, and industrial thermometry. Finally, the future of noise thermometry is considered. As the only purely electronic approach to thermodynamic temperature measurement, Johnson noise thermometry has appeal for metrological applications at temperatures ranging from below 1 µK up to 800 K. With the rapid advances in digital technologies, there are also expectations that noise thermometry will become a practical option for some industrial applications reaching temperatures above 2000 K.

3.
Metrologia ; 552018.
Artigo em Inglês | MEDLINE | ID: mdl-31080297

RESUMO

The International Committee for Weights and Measures (CIPM), at its meeting in October 2017, followed the recommendation of the Consultative Committee for Units (CCU) on the redefinition of the kilogram, ampere, kelvin and mole. For the redefinition of the kelvin, the Boltzmann constant will be fixed with the numerical value 1.380 649 × 10-23 J K-1. The relative standard uncertainty to be transferred to the thermodynamic temperature value of the triple point of water will be 3.7 × 10-7, corresponding to an uncertainty in temperature of 0.10 mK, sufficiently low for all practical purposes. With the redefinition of the kelvin, the broad research activities of the temperature community on the determination of the Boltzmann constant have been very successfully completed. In the following, a review of the determinations of the Boltzmann constant k, important for the new definition of the kelvin and performed in the last decade, is given.

4.
Metrologia ; 54(5): 730-737, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29056763

RESUMO

A value for the Boltzmann constant was measured electronically using an improved version of the Johnson Noise Thermometry (JNT) system at the National Institute of Standards and Technology (NIST), USA. This system is different from prior ones, including those from the 2011 determination at NIST and both 2015 and 2017 determinations at the National Institute of Metrology (NIM), China. As in all three previous determinations, the main contribution to the combined uncertainty is the statistical uncertainty in the noise measurement, which is mitigated by accumulating and integrating many weeks of cross-correlated measured data. The second major uncertainty contribution also still results from variations in the frequency response of the ratio of the measured spectral noise of the two noise sources, the sense resistor at the triple-point of water and the superconducting quantum voltage noise source. In this paper, we briefly describe the major differences between our JNT system and previous systems, in particular the input circuit and approach we used to match the frequency responses of the two noise sources. After analyzing and integrating 49 days of accumulated data, we determined a value: k = 1.380 642 9(69)×10-23 J/K with a relative standard uncertainty of 5.0×10-6 and relative offset -4.05×10-6 from the CODATA 2014 recommended value.

5.
Rev Sci Instrum ; 79(4): 044704, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18447541

RESUMO

We have performed a variety of precision measurements by comparing ac and dc waveforms generated by two independent ac programmable Josephson voltage standard (ACPJVS) systems. The objective of these experiments was to demonstrate the effectiveness of using a sampling digital voltmeter to measure small differences between Josephson waveforms for frequencies up to 3.6 kHz. The low uncertainties that we obtained confirm the feasibility of using this differential sampling method for high accuracy comparisons between ACPJVS waveforms and signals from other sources.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...