Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
CorSalud ; 12(3): 247-253, jul.-set. 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1154029

RESUMO

RESUMEN Introducción: Existen algunos estudios que relacionan parámetros de la onda P con diferentes tiempos de conducción auricular, pero no se han realizado teniendo en cuenta a cada derivación del electrocardiograma. Objetivo: Determinar la duración de la onda P (Pdur) en las 12 derivaciones y relacionarlas con el tiempo de conducción interauricular. Método: Estudio de corte transversal en 153 pacientes adultos con diagnóstico confirmado de taquicardia por reentrada intranodal (TRIN) o vías accesorias mediante estudio electrofisiológico invasivo. Resultados: Al comparar la Pdur entre sustratos arrítmicos por cada derivación, no existieron diferencias significativas, excepto en V6. En las derivaciones DII, DIII, aVR, aVF, V1 y de V3-V6 la Pdur se correlacionó con el tiempo de conducción interauricular en ambos sustratos arrítmicos. En el análisis multivariado, la Pdur constituyó un predictor independiente de tiempos de conducción interauricular ≥ 95 percentil, en las derivaciones de cara inferior y en V3, V5 y V6. Se observaron altos valores del área bajo la curva de la Característica Operativa del Receptor en las derivaciones DII (0,950; p<0,001), DIII (0,850; p<0,001) y V5 (0,891; p<0,001). Conclusiones: No existen diferencias por derivación en la Pdur al comparar casos con TRIN y vías accesorias, excepto en V6. La mayoría de las derivaciones se correlacionaron con el tiempo de conducción interauricular. La Pdur fue un predictor independiente de tiempos de conducción interauricular ≥ 95 percentil. La derivación DII presenta la mayor capacidad discriminativa para encontrar valores prolongados del tiempo de conducción interauricular.


ABSTRACT Introduction: Although some studies relate P wave parameters to different atrial conduction times, they do not consider each electrocardiogram lead separately. Objective: To determine the duration of P wave (Pdur) in the 12 leads of the electrocardiogram and relate it to the interatrial conduction time. Method: We conducted a cross-sectional study in 153 adult patients with confirmed diagnosis of atrioventricular nodal reentry tachycardia (AVNRT) or accessory pathways by invasive electrophysiological study. Results: When comparing the Pdur between arrhythmic substrates by each lead, no significant differences were found, except for V6. In leads II, III, aVR, aVF, V1 and V3-V6, Pdur was correlated with the interatrial conduction time in both arrhythmic substrates. In our multivariate analysis, the Pdur was an independent predictor of interatrial conduction times ≥ 95 percentile in inferior wall leads and in V3, V5 and V6. High values of the area under the receiver operating characteristic curve were observed in II (0.950; p<0.001), III (0.850; p<0.001) and V5 (0.891; p<0.001) leads. Conclusions: The Pdur showed no difference by leads when comparing cases with AVNRT and accessory pathways, except for V6. Most of the leads were correlated with the interatrial conduction time; Pdur was an independent predictor of interatrial conduction times ≥ 95 percentile. Lead II has the greatest discriminatory ability to find prolonged values of interatrial conduction time.


Assuntos
Taquicardia , Técnicas Eletrofisiológicas Cardíacas , Eletrocardiografia , Feixe Acessório Atrioventricular
2.
Acta méd centro ; 2(1)2008. ilus
Artigo em Espanhol | CUMED | ID: cum-41229

RESUMO

La descarga eléctrica es una de las causas más frecuentes de muerte por fenómenos naturales. La lesión cardíaca constituye su principal causa de mortalidad, en dependencia de las lesiones producidas por el tipo de impacto y de corriente. Presentamos el caso de una mujer de 38 años que sufrió, secundarias al impacto indirecto, pérdida del conocimiento y disfunción del ventrículo izquierdo por descarga eléctrica. En el momento del ingreso presentó polipnea, tercer ruido y, además, taquicardia sinusal en el electrocardiograma, el resto de las anomalías electrocardiográficas se presentaron a partir del segundo día de ingreso; presentó además alteraciones ecocardiográficas, que son más características del impacto directo. Ambos cambios se mantenían al egreso, aunque con mejoría clínica y ecocardiográfica luego de tratamiento médico. Después de la exposición del caso realizamos una breve revisión de las alteraciones producidas tras las descargas eléctricas(AU)


Assuntos
Humanos , Acidentes por Descargas Elétricas , Traumatismos Cardíacos/mortalidade , Miocardite , Taquicardia Sinusal , Eletrocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...