Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Obstet Gynecol MFM ; 4(3): 100593, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35144009

RESUMO

BACKGROUND: Preterm prelabor rupture of membranes is the most frequent complication of fetoscopic surgery. Strategies to seal the membrane defect created by fetoscopy have been attempted with little success. We previously developed an integrated semirigid bioadhesive patch composed of silicone and hydroxypropyl methylcellulose that achieved ex vivo sealing of membrane defects. OBJECTIVE: To evaluate the feasibility of the insertion of our integrated semirigid bioadhesive patches using a fetoscopic technique and to test the adhesion in ex vivo human membranes and in an in vivo ovine model. STUDY DESIGN: An experimental study involving 2 experiments: (1) ex vivo-human fetal membranes were mounted in a custom-designed model with saline solution simulating intraamniotic pressure. The insertion of 2 different bioadhesive patches made of silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose was performed through a 12-Fr cannula mimicking fetoscopic surgery technique. The experiment was repeated 10 times with membranes from different donors. Measures included insertion time, successful insertion, and adhesion at 5 minutes; (2) in vivo-16 patches of silicone-hydroxypropyl methylcellulose were inserted by fetoscopy in the amniotic cavity of pregnant sheep (4 bioadhesives per animal, in 4 ewes). Measures included successful insertion, adhesion at 5 minutes, and adhesion at the end of surgery. RESULTS: In the ex vivo insertion study, there was no difference in the insertion time between silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose patches (P=.49). Insertion was successful in all cases, but complete adhesion at 5 minutes was superior for silicone-hydroxypropyl methylcellulose (P=.02). In the in vivo study, insertion of silicone-hydroxypropyl methylcellulose by fetoscopy was feasible and successful in all cases, and no complications were reported. Adhesion persisted at 5 minutes and at the end of the surgery in 68.8% and 56.3% of the patches, respectively. CONCLUSION: We describe the feasibility of deploying through a fetoscopic trocar a semirigid silicone-hydroxypropyl methylcellulose patch that seals fetal membranes after an invasive fetal procedure. The results warrant further research for improving long-term adhesion and developing a clinically applicable system.


Assuntos
Fetoscopia , Poliuretanos , Animais , Feminino , Fetoscópios , Fetoscopia/métodos , Derivados da Hipromelose , Gravidez , Ovinos , Silicones
2.
J Biol Eng ; 15(1): 28, 2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34930385

RESUMO

Under intrauterine growth restriction (IUGR), abnormal attainment of the nutrients and oxygen by the fetus restricts the normal evolution of the prenatal causing in many cases high morbidity being one of the top-ten causes of neonatal death. The current gold standards in hospitals to detect this relevant problem is the clinical observation by echography, cardiotocography and Doppler. These qualitative techniques are not conclusive and requires risky invasive fetal scalp blood testing and/or amniocentesis. We developed micro-implantable multiparametric electrochemical sensors for measuring ischemia in real time in fetal tissue and vascular. This implantable technology is designed to continuous monitoring for an early detection of ischemia to avoid potential fetal injury. Two miniaturized electrochemical sensors were developed based on oxygen and pH detection. The sensors were optimized in vitro under controlled concentration, to assess the selectivity and sensitivity required. The sensors were then validated in vivo in the ewe fetus model, by means of their insertion in the muscle leg and inside the iliac artery of the fetus. Ischemia was achieved by gradually obstructing the umbilical cord to regulate the amount of blood reaching the fetus. An important challenge in fetal monitoring is the detection of low levels of oxygen and pH changes under ischemic conditions, requiring high sensitivity sensors. Significant differences were observed in both; pH and pO2 sensors under changes from normoxia to hypoxia states in the fetus tissue and vascular with both sensors. Herein, we demonstrate the feasibility of the developed sensors for future fetal monitoring in medical applications.

3.
Biomedicines ; 9(10)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34680459

RESUMO

Perinatal asphyxia is a major cause of severe brain damage and death. For its prenatal identification, Doppler ultrasound has been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. We have evaluated the performance of a miniaturized multiparametric sensor aiming to evaluate tissular oxygen and pH changes continuously in an umbilical cord occlusion (UCO) sheep model. The electrochemical sensors were inserted in fetal hindlimb skeletal muscle and electrochemical signals were recorded. Fetal hemodynamic changes and metabolic status were also monitored during the experiment. Additionally, histological assessment of the tissue surrounding the sensors was performed. Both electrochemical sensors detected the pO2 and pH changes induced by the UCO and these changes were correlated with hemodynamic parameters as well as with pH and oxygen content in the blood. Finally, histological assessment revealed no signs of alteration on the same day of insertion. This study provides the first evidence showing the application of miniaturized multiparametric electrochemical sensors detecting changes in oxygen and pH in skeletal muscular tissue in a fetal sheep model.

4.
Talanta ; 226: 122045, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33676640

RESUMO

Hypoxia is a common medical problem, sometimes difficult to detect and caused by different situations. Control of hypoxia is of great medical importance and early detection is essential to prevent life threatening complications. However, the few current methods are invasive, expensive, and risky. Thus, the development of reliable and accurate sensors for the continuous monitoring of hypoxia is of vital importance for clinical monitoring. Herein, we report an implantable sensor to address these needs. The developed device is a low-cost, miniaturised implantable electrochemical sensor for monitoring hypoxia in tissue by means of pH detection. This technology is based on protonation/deprotonation of polypyrrole conductive polymer. The sensor was optimized in vitro and tested in vivo intramuscularly and ex vivo in blood in adult rabbits with respiration-induced hypoxia and correlated with the standard device ePOCTM. The sensor demonstrated excellent sensitivity and reproducibility; 46.4 ± 0.4 mV/pH in the pH range of 4-9 and the selectivity coefficient exhibited low interference activity in vitro. The device was linear (R2 = 0.925) with a low dispersion of the values (n = 11) with a cut-off of 7.1 for hypoxia in vivo and ex vivo. Statistics with one-way ANOVA (α = 0.05), shows statistical differences between hypoxia and normoxia states and the good performance of the pH sensor, which demonstrated good agreement with the standard device. The sensor was stable and functional after 18 months. The excellent results demonstrated the feasibility of the sensors in real-time monitoring of intramuscular tissue and blood for medical applications.


Assuntos
Acidose , Polímeros , Animais , Hipóxia/diagnóstico , Pirróis , Coelhos , Reprodutibilidade dos Testes
5.
J Transl Med ; 19(1): 53, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33541374

RESUMO

BACKGROUND: One of the most prevalent causes of fetal hypoxia leading to stillbirth is placental insufficiency. Hemodynamic changes evaluated with Doppler ultrasound have been used as a surrogate marker of fetal hypoxia. However, Doppler evaluation cannot be performed continuously. As a first step, the present work aimed to evaluate the performance of miniaturized electrochemical sensors in the continuous monitoring of oxygen and pH changes in a model of acute hypoxia-acidosis. METHODS: pH and oxygen electrochemical sensors were evaluated in a ventilatory hypoxia rabbit model. The ventilator hypoxia protocol included 3 differential phases: basal (100% FiO2), the hypoxia-acidosis period (10% FiO2) and recovery (100% FiO2). Sensors were tested in blood tissue (ex vivo sensing) and in muscular tissue (in vivo sensing). pH electrochemical and oxygen sensors were evaluated on the day of insertion (short-term evaluation) and pH electrochemical sensors were also tested after 5 days of insertion (long-term evaluation). pH and oxygen sensing were registered throughout the ventilatory hypoxia protocol (basal, hypoxia-acidosis, and recovery) and were compared with blood gas metabolites results from carotid artery catheterization (obtained with the EPOC blood analyzer). Finally, histological assessment was performed on the sensor insertion site. One-way ANOVA was used for the analysis of the evolution of acid-based metabolites and electrochemical sensor signaling results; a t-test was used for pre- and post-calibration analyses; and chi-square analyses for categorical variables. RESULTS: At the short-term evaluation, both the pH and oxygen electrochemical sensors distinguished the basal and hypoxia-acidosis periods in both the in vivo and ex vivo sensing. However, only the ex vivo sensing detected the recovery period. In the long-term evaluation, the pH electrochemical sensor signal seemed to lose sensibility. Finally, histological assessment revealed no signs of alteration on the day of evaluation (short-term), whereas in the long-term evaluation a sub-acute inflammatory reaction adjacent to the implantation site was detected. CONCLUSIONS: Miniaturized electrochemical sensors represent a new generation of tools for the continuous monitoring of hypoxia-acidosis, which is especially indicated in high-risk pregnancies. Further studies including more tissue-compatible material would be required in order to improve long-term electrochemical sensing.


Assuntos
Acidose , Oxigênio , Animais , Feminino , Concentração de Íons de Hidrogênio , Hipóxia , Modelos Animais , Gravidez , Coelhos
6.
Sci Rep ; 10(1): 18608, 2020 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-33122661

RESUMO

Preterm prelabor rupture of membranes (PPROM) is the most frequent complication of fetal surgery. Strategies to seal the membrane defect created by fetoscopy aiming to reduce the occurrence of PPROM have been attempted with little success. The objective of this study was to evaluate the ex-vivo mechanical sealing properties and toxicity of four different bioadhesives integrated in semi-rigid patches for fetal membranes. We performed and ex-vivo study using term human fetal membranes to compare the four integrated patches composed of silicone or silicone-polyurethane combined with dopaminated-hyaluronic acid or hydroxypropyl methylcellulose (HPMC). For mechanical sealing properties, membranes were mounted in a multiaxial inflation device with saline, perforated and sealed with the 4 combinations. We measured bursting pressure and maximum pressure free of leakage (n = 8). For toxicity, an organ culture of membranes sealed with the patches was used to measure pyknotic index (PI) and lactate dehydrogenase (LDH) concentration (n = 5). All bioadhesives achieved appropriate bursting pressures, but only HPMC forms achieved high maximum pressures free of leakage. Concerning toxicity, bioadhesives showed low PI and LDH levels, suggesting no cell toxicity. We conclude that a semi-rigid patch coated with HPMC achieved ex-vivo sealing of iatrogenic defects in fetal membranes with no signs of cell toxicity. These results warrant further research addressing long-term adhesiveness and feasibility as a sealing system for fetoscopy.


Assuntos
Adesivos/uso terapêutico , Membranas Extraembrionárias/cirurgia , Ruptura Prematura de Membranas Fetais/cirurgia , Doença Iatrogênica/prevenção & controle , Membranas Extraembrionárias/metabolismo , Feminino , Ruptura Prematura de Membranas Fetais/metabolismo , Fetoscopia/métodos , Idade Gestacional , Humanos , Ácido Hialurônico/administração & dosagem , Derivados da Hipromelose/administração & dosagem , L-Lactato Desidrogenase/metabolismo , Técnicas de Cultura de Órgãos/métodos , Poliuretanos/administração & dosagem , Gravidez , Silicones/administração & dosagem
7.
Am J Physiol Gastrointest Liver Physiol ; 309(10): G801-6, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26405114

RESUMO

Stabilization of mast cell (MC) degranulation has been proposed to prevent postoperative ileus (POI). Nerve growth factor (NGF) mediates MC degranulation. The aim of the study was to evaluate whether NGF receptor antagonist K252a acts as a MC stabilizer in vitro and in vivo model of POI. Peritoneal mast cells (PMCs) were obtained from Sprague-Dawley rats and were incubated with K252a and exposed to NGF or Compound 48/80 (C48/80). MC degranulation was assessed by ß-hexosaminidase assay. POI was induced in rats by intestinal manipulation (IM). Rats were pretreated with K252a (100 µg/kg sc) 20 min prior to POI induction. At 20 min after IM, release of rat mast cell protease 6 (RMCP-6) was evaluated in peritoneal lavage. At 24 h, intestinal transit (IT) and gastric emptying (GE) were evaluated. Ileal inflammation was assessed by myeloperoxidase (MPO) activity, expression of IL-6, NGF, TrkA, RMCP-2 and 6, and MC density within the full-thickness ileum. C48/80 and NGF evoked degranulation of PMCs in a dose-dependent manner. K252a prevented NGF-evoked, but not C48/80-evoked, MC degranulation. IM evoked the release of peritoneal RMCP-6 and subsequently delayed IT and GE. IM increased MPO activity and expression of IL-6. In IM rats, K252a prevented upregulation of IL-6 expression and reduced TrkA. IT, GE, and inflammation were not affected by K252a. K252a inhibited NGF-evoked degranulation of PMCs in vitro. In vivo, K252a decreased IL-6 and PMC degranulation. This may be of relevance for the development of new therapeutic targets for POI.


Assuntos
Carbazóis/farmacologia , Degranulação Celular/efeitos dos fármacos , Íleus , Alcaloides Indólicos/farmacologia , Mastócitos , Complicações Pós-Operatórias , Receptor de Fator de Crescimento Neural/antagonistas & inibidores , Animais , Modelos Animais de Doenças , Monitoramento de Medicamentos , Esvaziamento Gástrico/efeitos dos fármacos , Fármacos Gastrointestinais/farmacologia , Motilidade Gastrointestinal/efeitos dos fármacos , Íleus/tratamento farmacológico , Íleus/etiologia , Íleus/metabolismo , Íleus/patologia , Interleucina-6/metabolismo , Masculino , Mastócitos/efeitos dos fármacos , Mastócitos/metabolismo , Fator de Crescimento Neural/metabolismo , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/metabolismo , Complicações Pós-Operatórias/patologia , Ratos , Ratos Sprague-Dawley , Resultado do Tratamento , Triptases/metabolismo , p-Metoxi-N-metilfenetilamina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...