Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Inn Med (Heidelb) ; 2024 Jul 15.
Artigo em Alemão | MEDLINE | ID: mdl-39007960

RESUMO

Atrial fibrillation and heart failure are among the most common cardiovascular diseases and have a significant impact on the mortality and morbidity of affected patients. From a pathophysiological perspective, the two diseases are closely related and often perpetuate each other. Therefore, effective management of atrial fibrillation is now a central component of modern heart failure treatment. Based on current data, sinus rhythm should primarily be permanently maintained in patients with systolic heart failure. Catheter ablation has recently proven to be advantageous over purely pharmacological therapy and is therefore the treatment of choice for many patients with heart failure and atrial fibrillation. In patients with diastolic heart failure (heart failure with preserved ejection fraction [HFpEF]), the effect of catheter ablation is less clear. Data from randomized studies are urgently needed in order to further assess efficacy in this population.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39009785

RESUMO

BACKGROUND: Personalized radiofrequency (RF) ablation for paroxysmal atrial fibrillation (PAF), adapting the ablation index (AI) to local left atrial wall thickness (LAWT), proved to be highly efficient maintaining high arrhythmia-free survival rates. However, multicentre data are lacking. This multicentre, prospective, non-randomized study was conducted at 5 tertiary hospitals and sought to assess the safety, efficacy, and reproducibility of the LAWT-guided ablation for PAF. METHODS: Consecutive patients referred for first-time PAF were prospectively enrolled. The LAWT maps were obtained from preprocedural multidetector computed tomography and integrated into the navigation system. AI was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the pulmonary veins (PVs). RESULTS: A total 109 patients (60.1 ± 9.4 years, 64.2% male) were enrolled. Median procedure time was 61.7 min (48.4-83.8), fluoroscopy time was 1.0 min (0.4-3.3), and RF time was 13.9 min (12.3-16.8). Median AI tailored to the local LAWT was 393 (374-412) for the anterior wall and 340 (315-378) for the posterior wall. Right and left PVs first-pass isolation was achieved in 89% and 91.7% of the patients, respectively. At 12-month follow-up, freedom from any atrial arrhythmia was 93.4% (95% CI 88.7-98.1), without differences across centres (P = 0.169). One patient experienced femoral artery pseudoaneurysm, with no other serious procedural-related complication. CONCLUSION: The Ablate-by-LAWT study proved that LAWT-guided PV isolation for PAF is safe, effective, and efficient in a multicentre setting. Twelve-month recurrence-free survival exceeded 90% (NCT04218604).

3.
Artigo em Inglês | MEDLINE | ID: mdl-38997610

RESUMO

INTRODUCTION: Pulsed-field energy (PFA) and very high-power short-duration radiofrequency (vHPSD-RF) are two novel ablation methods for pulmonary vein isolation (PVI). Both PFA and vHPSD-RF show promise for improving efficacy, safety, and reducing procedure durations. However, direct comparisons between these two techniques are scarce. METHODS AND RESULTS: Retrospective analysis of 82 patients with symptomatic AF. Of these, 52 patients received PFA and 30 received vHPSD-RF (90 W, 4 s) as index procedure. At the 6-month follow-up, AF recurrence occurred in 4 patients following PFA and 5 patients following vHPSD-RF (p-value = 0.138). Significant improvements in the EHRA and NYHA stages were evident in both PFA (p < 0.001 and p = 0.047, respectively) and vHPSD-RF groups (p = 0.007 and p = 0.012, respectively). The total procedure duration and the left atrial dwell time were significantly shorter in the PFA group (64 ± 19 min vs. 99 ± 32 min, p < 0.001 and 41 ± 12 min vs. 62 ± 29 min, p < 0.001, respectively). The fluoroscopy time and dose area product were significantly higher in PFA (14 ± 6 vs. 9 ± 5 min, p < 0.001 and 14 ± 9 vs. 11 ± 9 Gy cm2, p = 0.046, respectively). One patient in the vHPSD-RF group suffered a stroke, not directly linked to the procedure (0 vs. 1 major complication, p = 0.366). CONCLUSION: Based on this retrospective single-center study, PFA and vHPSD-RF were associated with similar effectiveness and safety profiles. PFA was linked to shorter procedure times and higher radiation exposure compared to vHPSD-RF.

5.
Heart Rhythm ; 21(7): 1008-1015, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38604590

RESUMO

BACKGROUND: The CASTLE-HTx trial demonstrated the benefit of atrial fibrillation (AF) ablation compared with medical therapy in decreasing mortality, need for left ventricular assist device implantation, or heart transplantation (HTx) in patients with end-stage heart failure (HF). OBJECTIVE: This analysis aimed to identify risk factors related to adverse outcomes in patients with end-stage HF and to assess the impact of ablation. METHODS: The CASTLE-HTx protocol randomized 194 patients with end-stage HF and AF to ablation vs medical therapy. We identified left ventricular ejection fraction <30%, New York Heart Association class ≥III, and AF burden >50% as predictors for the primary end point. The CASTLE-HTx risk score assigned weights to these risk factors. Patients with a risk score ≥3 were identified as high risk. RESULTS: The patients were assigned to low-risk (89 [45.9%]) and high-risk (105 [54.1%]) groups. After a median follow-up of 18 months, a primary end point event occurred in 6 and 31 patients of the low- and high-risk groups (hazard ratio, 4.98; 95% confidence interval, 2.08-11.9). The incidence rate (IR) difference between ablation and medical therapy was much larger in high-risk patients (8/49 [IR, 11.4] vs 23/56 [IR, 36.1]) compared with low-risk patients (2/48 [IR, 2.6] vs 4/41 [IR, 6.3]). The IR difference for ablation was significantly higher in high-risk patients (24.69) compared with low-risk patients (3.70). CONCLUSION: The absolute benefit of ablation is more pronounced in high-risk patients, but low-risk patients may also benefit. The CASTLE-HTx risk score identifies patients with end-stage HF who will particularly benefit from ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/complicações , Masculino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/complicações , Feminino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Prognóstico , Volume Sistólico/fisiologia , Transplante de Coração , Fatores de Risco , Idoso , Seguimentos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Taxa de Sobrevida/tendências
6.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38516791

RESUMO

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluxo de Trabalho , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva
7.
Inn Med (Heidelb) ; 65(1): 29-37, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-38172337

RESUMO

Atrial fibrillation (AF) is the most frequent cardiac arrhythmia with increasing clinical and healthcare economic relevance. A timely treatment prevents or slows the remodelling process of the atrial and ventricular myocardium initiated by AF, emphasizing its relevance especially in heart failure patients. Catheter ablation for the treatment of AF is safe and effective. The three ablation techniques currently used are comparable in terms of success rates but differ in terms of risk profile and the type of lesion formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Risco , Medição de Risco/métodos , Ablação por Cateter/efeitos adversos
8.
Heart Vessels ; 39(5): 427-437, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38189924

RESUMO

BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation in combination with contact force sensing (MCN-CF) ablation of atrial fibrillation (AF) is lacking. The primary aim of the present retrospective comparative study was to compare the outcome of RMN versus (vs.) MCN-CF ablation of AF with regards to AF recurrence. Secondary aim was to analyze periprocedural risk, ablation characteristics and repeat procedures. METHODS: We retrospectively analyzed 452 patients undergoing a total of 605 ablations of AF: 180 patients were ablated using RMN, 272 using MCN-CF. RESULTS: Except body mass index there was no significant difference between groups at baseline. After a mean 1.6 ± 1.6 years of follow-up and 1.3 ± 0.4 procedures, 81% of the patients in the MCN-CF group remained free of AF recurrence compared to 53% in the RMN group (P < 0.001). After analysis of 153 repeat ablations (83 MCN-RF vs. 70 RMN; P = 0.18), there was a significantly higher reconnection rate of pulmonary veins after RMN ablation (P < 0.001). In multivariable Cox-regression analysis, RMN ablation (P < 0.001) and left atrial diameter (P = 0.013) was an independent risk factor for AF recurrence. Procedure time, radiofrequency application time and total fluoroscopy time and fluoroscopy dose were higher in the RMN group without difference in total number of ablation points. Complication rates did not differ significantly between groups (P = 0.722). CONCLUSIONS: In our retrospective comparative study, the AF recurrence rate and pulmonary vein reconnection rate is significantly lower with more favorable procedural characteristics and similar complication rate utilizing MCN-CF compared to RMN.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos , Veias Pulmonares/cirurgia
9.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885302

RESUMO

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração , Imageamento por Ressonância Magnética/métodos
10.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37634135

RESUMO

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Alemanha , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Encaminhamento e Consulta , Resultado do Tratamento
11.
J Interv Card Electrophysiol ; 66(9): 2125-2133, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37145294

RESUMO

BACKGROUND: Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This observational study aimed to assess the role of individual anatomical characteristics to predict long-term freedom from arrhythmia recurrence after CB-guided PVI for paroxysmal AF (PAF). METHODS: Three hundred fifty three consecutive patients (58 ± 11 years, 56% males), undergoing PVI between 2012 and 2018 were analysed. Individual pulmonary vein (PV) anatomy was assessed using preprocedural cardiac magnetic resonance imaging (MRI). For each PV, the cross-sectional area (CSA) was calculated. The impact of PV characteristics and CSA on long-term AF-free survival was evaluated. RESULTS: Acute PVI was achieved in all patients. Two hundred twenty-three patients (63%) had a normal PV anatomy (2 left- and 2 right-sided PV). Variant PV anatomy was present in 130 patients (37%). During the observation period of 48 months, AF-recurrence was documented in 167 patients (47 %). Patients with AF-recurrence presented with significantly enlarged right-sided PVs and left superior PVs (LSPVs) (p < 0.001). The presence of left common PVs (LCPVs) (n = 75, Log-rank p < 0.001) as well as right variant PVs (n = 35, Log rank p < 0.001) was associated with a significantly impaired long-term AF-free survival rate as compared to patients with normal PV characteristics. CONCLUSION: Variant PV anatomy is a good predictor for AF-recurrence. A correlation between an enlarged CSA of right-sided PVs as well as LSPVs and AF-recurrence was documented.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Imageamento por Ressonância Magnética , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva
14.
Europace ; 25(4): 1392-1399, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36815300

RESUMO

AIMS: Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). METHODS AND RESULTS: Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. CONCLUSION: Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Meios de Contraste , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Cicatriz/patologia , Fluxo de Trabalho , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/patologia , Resultado do Tratamento , Recidiva
15.
Cardiol J ; 30(1): 36-43, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36588311

RESUMO

BACKGROUND: The DiamondTemp (DT) radiofrequency ablation (RFA) catheter has been introduced as a new tool for atrial fibrillation (AF) ablation. The new technology allows for temperature-controlled irrigated ablation and real-time lesion assessment. Recently, the EnSite X mapping system became commercially available allowing for omnipolar and ultra-high-resolution mapping. We aimed to assess the feasibility of the new DT RFA catheter in performing AF ablation procedures in conjunction with the novel EnSite X system under routine clinical conditions. METHODS: We analyzed data from 10 consecutive patients who underwent AF ablation using the DT RFA catheter guided by EnSite X. Procedural data and short-term follow-up were assessed as well as potential technical issues. RESULTS: Nine out of 10 patients underwent de-novo pulmonary vein isolation (PVI), and 1 patient underwent repeat ablation. First-pass isolation was observed in 7/10 patients. Total procedure duration (skin-to-skin) was 88.9 ± 30.1 min, and left atrium dwell time was 70 ± 22.3 min. The mean number of RF applications needed for PVI and additional ablation was 70.52 ± 26.70. The HD Grid SE mapping catheter was utilized in 8 patients and the Advisor SE in 2 patients. Bidirectional block of the applied lines was achieved in all patients. No steam pops were observed, and no intraprocedural complications occurred. CONCLUSIONS: This first clinical series demonstrated that temperature-controlled irrigated ablation in combination with the novel omnipolar and high-resolution mapping system resulted in rapid, efficient, and durable lesion formation under routine clinical conditions. Randomized controlled trials are needed to elucidate the impact on lesion formation, long-term outcomes, and reproducibility of our initial findings.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Reprodutibilidade dos Testes , Resultado do Tratamento , Desenho de Equipamento , Catéteres , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
17.
Europace ; 25(2): 600-609, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504238

RESUMO

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Criança , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia/métodos , Algoritmos
18.
Clin Res Cardiol ; 112(6): 795-806, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36131138

RESUMO

PURPOSE: Pulsed-field ablation (PFA) is a new energy source to achieve pulmonary vein isolation (PVI) by targeted electroporation of cardiomyocytes. Experimental and controlled clinical trial data suggest good efficacy of PFA-based PVI. We aimed to assess efficacy, safety and follow-up of PFA-based PVI in an early adopter routine care setting. METHODS: Consecutive patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) underwent PVI using the Farawave® PFA ablation catheter in conjunction with three-dimensional mapping at two German high-volume ablation centers. PVI was achieved by applying 8 PFA applications in each PV. RESULTS: A total of 138 patients undergoing a first PVI (67 ± 12 years, 66% male, 62% persistent AF) were treated. PVI was achieved in all patients by deploying 4563 applications in 546 PVs (8.4 ± 1.0/PV). Disappearance of PV signals after the first application was demonstrated in 544/546 PVs (99.6%). More than eight PFA applications were performed in 29/546 PVs (6%) following adapted catheter positioning or due to reconnection as assessed during remapping. Mean procedure time was 78 ± 22 min including pre- and post PVI high-density voltage mapping. PFA catheter LA dwell-time was 23 ± 9 min. Total fluoroscopy time and dose area product were 16 ± 7 min and 505 [275;747] cGy*cm2. One pericardial tamponade (0.7%), one transient ST-elevation (0.7%) and three groin complications (2.2%) occurred. 1-year follow-up showed freedom of arrhythmia in 90% in patients with paroxysmal AF (n = 47) and 60% in patients with persistent AF (n = 82, p = 0.015). CONCLUSIONS: PFA-based PVI is acutely highly effective and associated with a beneficial safety and low recurrence rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Seguimentos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluoroscopia , Resultado do Tratamento , Recidiva
19.
J Cardiovasc Electrophysiol ; 33(12): 2517-2527, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36104929

RESUMO

INTRODUCTION: Approaches applying higher energy levels for shorter periods (high power short duration, HPSD) to improve lesion formation for atrial fibrillation (AF) ablation have been introduced. This single-center study aimed to compare the efficacy, safety, and lesion formation using the novel DiamondTemp (DT) catheter or an ablation index (AI)-guided HPSD ablation protocol using a force-sensing catheter with surround-flow irrigation. METHODS: One hundred thirteen consecutive patients undergoing radiofrequency-guided catheter ablation (RFCA) for AF were included. Forty-five patients treated with the DT catheter (50 W, 9 s), were compared to 68 consecutive patients undergoing AI-guided ablation (AI anterior 550; AI posterior 400) adherent to a 50 W HPSD protocol. Procedural data and AF recurrence were evaluated. RESULTS: Acute procedural success was achieved in all patients (n = 113, 100%). DT-guided AF ablation was associated with a longer mean procedure duration (99.10 ± 28.30 min vs. 78.24 ± 25.55, p < .001) and more RF applications (75.24 ± 30.76 min vs. 61.27 ± 14.06, p = .019). RF duration (792.13 ± 311.23 s vs. 1035.54 ± 287.24 s, p < .001) and fluoroscopy dose (183.81 ± 178.13 vs. 295.80 ± 247.54 yGym2 , p = .013) were lower in the DT group. AI-guided HPSD was associated with a higher AF-free survival rate without reaching statistical significance (p = .088). Especially patients with PERS AF (p = .009) as well as patients with additional atrial arrhythmia substrate (p = .002) benefited from an AI-guided ablation strategy. CONCLUSION: Temperature- and AI- controlled HPSD RFCA using 50 W was safe and effective. AI-guided HPSD ablation seems to be associated with shorter procedure durations and fewer RF applications. Particularly in advanced AF, freedom from AF-recurrence may be improved using an AI-guided HPSD approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...