Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1333-1339, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37558289

RESUMO

BACKGROUND: The wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death due to ventricular tachycardia (VT) or ventricular fibrillation (VF) but does not pace for post-shock asystole (PS-A) or bradycardia (PS-B;<50 beats/ min). OBJECTIVES: The purpose of this study was to assess PS-A and PS-B in patients dying out of hospital (OOH) while wearing a WCD. METHODS: The database of the U.S. Food and Drug Administration Manufacturers and User Facility Device Experience (MAUDE) was queried for manufacturers' reports of OOH deaths while patients were wearing a WCD. Excluded were patients who did not receive a shock or were initially shocked for asystole or during resuscitation. RESULTS: From January 2017 to March 2022, 313 patients received an initial WCD shock for VF (n = 150), VT (n = 90), and non-VF/VT rhythms (n = 73). PS-A occurred in 204 patients (65.2%), and PS-B occurred in 111 (35.5%); 85 (41.7%) PS-A patients also had PS-B. Most PS-A patients (n = 185; 90.7%) had an initial shocked rhythm of VF or VT, but 19 patients (9.3%) were initially inappropriately shocked for atrial fibrillation/supraventricular tachycardia (n = 7) and idioventricular (n = 8) or sinus (n = 4) rhythm. PS-A occurred after the first WCD shock in 118 (63.8%) and after the first, second, or third shocks in 159 patients (85.9%). Seven patients had post-shock heart block. Eight patients had permanent pacemakers; 1 became nonfunctional after 1 shock, and 7 showed noncapture and/or asystole after 1 to 4 shocks. CONCLUSIONS: Post-shock asystole appears to be common in patients who die OOH after being shocked by a WCD for VF or VT. PS-A also occurs after inappropriate WCD shocks for non-VF/VT rhythms. Implanted pacemakers may not prevent PS-A after a WCD shock. WCD backup pacing should be explored.


Assuntos
Fibrilação Atrial , Parada Cardíaca , Taquicardia Ventricular , Estados Unidos , Humanos , Cardioversão Elétrica/efeitos adversos , Parada Cardíaca/terapia , Fibrilação Ventricular , Desfibriladores , Hospitais
2.
Heart Rhythm ; 20(7): 970-975, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37211148

RESUMO

BACKGROUND: The LifeVest® wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death in at-risk patients who are not candidates for an implantable defibrillator. The safety and efficacy of the WCD may be impacted by inappropriate shocks (IAS). OBJECTIVE: The purpose of this study was to assess the causes and clinical consequences of WCD IAS in survivors of IAS events. METHODS: The Food and Drug Administration's Manufacturers and User Facility Device Experience database was searched for IAS adverse events (AE) that were reported during 2021 and 2022. RESULTS: A total of 2568 IAS-AE were found (average number of IAS per event: 1.5 ± 1.9; range 1-48). IAS were caused by tachycardias (1255 [48.9%]), motion artifacts (840 [32.7%]), and oversensing (OS) of low-level electrical signals (473 [18.4%]) (P <.001). Tachycardias included atrial fibrillation (AF) (828 [32.2%]), supraventricular tachycardia (SVT) (333 [13.0%]), and nonsustained ventricular tachycardia/fibrillation (NSVT/VF) (87 [3.4%]). Activities responsible for motion-induced IAS included riding a motorcycle, lawnmower, or tractor (n = 128). In 19 patients, IAS induced sustained ventricular tachycardia or ventricular fibrillation that subsequently were terminated by appropriate WCD shocks. Thirty patients fell and suffered physical injuries. Conscious patients (n = 1905) did not use the response buttons to abort shocks (47.9%) or used them improperly (20.2%). IAS resulted in 1190 emergency room visits or hospitalizations, and 17.3% of patients (421/2440) discontinued the WCD after experiencing IAS, especially multiple IAS. CONCLUSIONS: The LifeVest WCD may deliver IAS caused by AF, SVT, NSVT/VF, motion artifacts, and oversensing of electrical signals. These shocks may be arrhythmogenic, result in injuries, precipitate WCD discontinuation, and consume medical resources. Improved WCD sensing, rhythm discrimination, and methods to abort IAS are needed.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Cardioversão Elétrica/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Ventricular , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Atrial/complicações , Taquicardia Supraventricular/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...