Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 152(5): 1333-1342.e3, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27637422

RESUMO

OBJECTIVES: The goal of this single-center series was to assess differences in reintervention by the type of valve used for surgical bioprosthetic pulmonary valve replacement and to identify independent predictors of reintervention. METHODS: Data were retrospectively collected for 611 patients undergoing pulmonary valve replacement from 1996 to 2014. Kaplan-Meier estimation and Cox proportional hazards regression methodologies were used. RESULTS: The median age of patients was 17.8 years (interquartile range, 11.9-27.3). The diagnosis was tetralogy of Fallot in 69% of patients. The median follow-up was 3.0 years (interquartile range, 1.1-5.3). Valve types included Sorin Mitroflow (Milan, Italy), 316 (50%; median age 16.5 years); Carpentier-Edwards (Irvine, Calif) Magna/MagnaEase, 223 (35%; median age, 19.3 years); and Carpentier-Edwards Perimount, 72 (11%; median age, 21.9 years). Reintervention occurred in 6.7% of patients (41/633) and was higher in children than adults (hazard ratio, 4.8). Age-adjusted 5-year reintervention rates were Sorin Mitroflow, 13.4%; Carpentier-Edwards Magna/MagnaEase, 2.1%; and Carpentier-Edwards Perimount, 0%. Reintervention was not associated with gender, valve insertion method, or concurrent procedures. The only independent risk factor for reintervention after controlling for age was valve type (P < .001). The Sorin Mitroflow valve had a shorter time to reintervention than the other 2 valve types (hazard ratios both >7, each P < .001). Differences by valve type did not depend on age (interaction P = .61). CONCLUSIONS: Bioprosthetic pulmonary valve replacement in patients with congenital heart disease has excellent short-term outcomes, but children have an approximately 5-fold greater risk of reintervention than adults. Independently of age, reintervention rates vary by valve type. These differences may be important in valve selection and follow-up.


Assuntos
Bioprótese , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
2.
Congenit Heart Dis ; 5(3): 233-42, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20576042

RESUMO

INTRODUCTION: Procedural cooperation between cardiac surgeon and interventional cardiologist to facilitate interventions such as device delivery or angioplasty (hybrid procedure) has become increasingly common in the management of patients with congenital heart disease. DESIGN: Data were prospectively collected using a multicenter registry (C3PO). Between February 2007 and December 2008, seven institutions submitted data regarding 7019 cardiac catheterization procedures. Procedural data and adverse events (AEs) of 128 hybrid procedures were evaluated. RESULTS: There was significant variability in the number of hybrid procedures per center, ranging from one to 89 with a median of eight. A total of 60% of interventional (vs. strictly diagnostic) hybrid procedures were performed by one center. The median weight was 3.7 kg (0.7-86 kg). Single-ventricle circulation was present in 60% of the procedures. Hybrid procedures included: patent ductus arteriosus (PDA) stent placement (n = 55), vascular rehabilitation (n = 25), ventricular septal defect (VSD) device closure (n = 7), valvotomy (n = 3), and diagnostic hybrid procedures (n = 38). Sixteen AEs occurred in 15/128 (12%) procedures. These included minor or trivial AEs (n = 9), moderate AEs (n = 5), major AEs (n = 1), and catastrophic AEs (n = 1). The type of AE documented included arrhythmias (n = 6), hypoxia or hypotension (n = 3), vessel or cardiac trauma (n = 2), and other events (n = 5). Of documented AEs, 9/16 (56%) were classified as not preventable, 6/16 (38%) as possibly preventable, and 1/16 (6%) as preventable. The incidence of AE related to PDA stent placement with surgical exposure (5/50, 10%) was significantly lower when compared with PDA stent placement performed percutaneously (4/5, 80%, P= .002). CONCLUSION: Hybrid procedures appear to have a low incidence of associated major AEs. PDA stent placement performed as a palliation of hypoplastic left heart syndrome (HLHS) or complex single/two ventricle patients may have a lower incidence of AEs if performed using a direct approach with surgical exposure rather than a percutaneous approach. Accurate definitions of these innovative procedures are required to facilitate prospective data collection.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/estatística & dados numéricos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Criança , Pré-Escolar , Comportamento Cooperativo , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Cuidados Paliativos , Equipe de Assistência ao Paciente , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...