1.
J Orthop Res ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38924183

RESUMO

Flexor tendon injury is a common hand trauma that requires surgical repair. The objective was to compare the repaired strength and gliding resistance with a varied number of repair strands and of square knots using a two-strand-overhand locking (TSOL) knot. First, isolated suture loops with different number of suture strands and number of closing knots were compared in mechanical strength and failure mode. Then, 90 flexor digitorum profundus (FDP) tendons from turkey digits were used for the tendon repair experiment. Both phases followed a similar 3 × 3 matrix comparing the knot type including TSOL+1SK (square knot), TSOL+2SK, and TSOL+3 SK and repair techniques including two-, four-, and six-strand repairs techniques respectively. The repaired tendons were tested for tendon resistance against pulley (friction), maximum force, force at 2 mm displacement, stiffness, and failure mode. Increasing the number of strands and closing square knots increases the tensile strength and stiffness of flexor tendon repairs and isolated suture loops without a significant effect on tendon friction. An increase in the number of square knots have shown increased strength only in Pennington repair, which correlated with the increased number of knot unraveling, a weak knot failure model. Our data demonstrated that increasing the number of strands is effective for improving the overall strength of tendon repair. When a two-strand repair is chosen, increasing knot number can improve repair strength. However, the number of knots appears not affecting repair strength in six-strand repair technique.

2.
Clin Gastroenterol Hepatol ; 20(12): 2780-2789, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35307593

RESUMO

BACKGROUND & AIMS: Duodenoscope-associated transmission of infections has raised questions about efficacy of endoscope reprocessing using high-level disinfection (HLD). Although ethylene oxide (ETO) gas sterilization is effective in eradicating microbes, the impact of ETO on endoscopic ultrasound (EUS) imaging equipment remains unknown. In this study, we aimed to compare the changes in EUS image quality associated with HLD vs HLD followed by ETO sterilization. METHODS: Four new EUS instruments were assigned to 2 groups: Group 1 (HLD) and Group 2 (HLD + ETO). The echoendoscopes were assessed at baseline, monthly for 6 months, and once every 3 to 4 months thereafter, for a total of 12 time points. At each time point, review of EUS video and still image quality was performed by an expert panel of reviewers along with phantom-based objective testing. Linear mixed effects models were used to assess whether the modality of reprocessing impacted image and video quality. RESULTS: For clinical testing, mixed linear models showed minimal quantitative differences in linear analog score (P = .04; estimated change, 3.12; scale, 0-100) and overall image quality value (P = .007; estimated change, -0.12; scale, 1-5) favoring ETO but not for rank value (P = .06). On phantom testing, maximum depth of penetration was lower for ETO endoscopes (P < .001; change in depth, 0.49 cm). CONCLUSIONS: In this prospective study, expert review and phantom-based testing demonstrated minimal differences in image quality between echoendoscopes reprocessed using HLD vs ETO + HLD over 2 years of clinical use. Further studies are warranted to assess the long-term clinical impact of these findings. In the interim, these results support use of ETO sterilization of EUS instruments if deemed clinically necessary.


Assuntos
Contaminação de Equipamentos , Óxido de Etileno , Humanos , Estudos Prospectivos , Reutilização de Equipamento , Desinfecção/métodos
3.
Clin Biomech (Bristol, Avon) ; 82: 105277, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33513456

RESUMO

BACKGROUND: McArdle sign is a phenomenon of impaired gait and muscle weakness that occurs with neck flexion, immediately reversible with neck extension. A recent report measured the specificity of this sign for multiple sclerosis by measuring differences in peak torque of the extensor digitorum between neck extension and flexion. METHODS: This substudy included 73 participants (29 multiple sclerosis, 20 non-multiple sclerosis myelopathies, 5 peripheral nerve disorders, and 19 healthy controls). The effect of neck position was assessed on muscle stiffness and neuromechanical error of the extensor digitorum. FINDINGS: Patients with multiple sclerosis had greater neuromechanical error (sum of squared error of prediction) compared to controls (P = 0.023) and non-multiple sclerosis myelopathies (P = 0.003). Neuromechanical error also provided improved sensitivity/specificity of McArdle sign. Peak torque, muscle stiffness, and neuromechanical error could distinguish multiple sclerosis from other myelopathies with 80% specificity and 97% sensitivity (AUC = 0.95). INTERPRETATION: A decrease in muscle stiffness and neuromechanical error in neck flexion compared to extension are additional indicators for a diagnosis of multiple sclerosis. Analysis of muscle stiffness may provide insights into the pathophysiology of this specific clinical sign for multiple sclerosis. Furthermore, muscle stiffness may provide an additional accurate, simple assessment to evaluate multiple sclerosis therapeutic interventions and disease progression.


Assuntos
Antebraço/fisiopatologia , Doença de Depósito de Glicogênio Tipo V/fisiopatologia , Fenômenos Mecânicos , Músculo Esquelético/fisiopatologia , Adulto , Fenômenos Biomecânicos , Feminino , Marcha , Humanos , Masculino , Adulto Jovem
4.
Bone Joint J ; 101-B(10): 1238-1247, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31564153

RESUMO

AIMS: Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function. MATERIALS AND METHODS: A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6). RESULTS: At eight weeks, FiberTape alone or FiberTape-augmented autograft demonstrated increased biomechanical stability compared with autograft regarding ultimate load to failure (p = 0.035), elongation (p = 0.006), and energy absorption (p = 0.022). FiberTape-grafted samples also demonstrated increased bone mineral density in the bone tunnel (p = 0.039). Histological evaluation showed integration of all grafts in the bone tunnels by new bone formation, and limited signs of inflammation overall. A lack of prolonged inflammation in all samples was confirmed by quantification of inflammation biomarkers. However, no regeneration of ligament-like tissue was observed along the suture tape materials. Except for one autograft failure, no adverse events were detected. CONCLUSION: Our results indicate that FiberTape increases the biomechanical performance of intra-articular ligament reconstructions in a verified rabbit model at eight weeks. Within this period, FiberTape did not adversely affect bone tunnel healing or invoke a prolonged elevation in inflammation. Cite this article: Bone Joint J 2019;101-B:1238-1247.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Polietilenos/química , Tendões/transplante , Resistência à Tração/fisiologia , Análise de Variância , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Feminino , Humanos , Peso Molecular , Coelhos , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Técnicas de Sutura , Suturas , Transplante Autólogo
5.
Mayo Clin Proc ; 94(8): 1427-1435, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31303427

RESUMO

OBJECTIVE: To measure McArdle sign (rapidly reversible weakness induced by neck flexion) both qualitatively and quantitatively and to evaluate its specificity and clinical utility for diagnosis of multiple sclerosis (MS). PATIENTS AND METHODS: In this prospective study, McArdle sign was evaluated by a technician blinded to diagnosis by measuring changes in finger extensor strength in successive trials of neck extension and flexion, first clinically and then with a torque measurement device. We studied 25 healthy controls and 81 patients with finger extensor weakness. Patients were not selected for having McArdle sign. Fifty-two patients had MS, 24 had other myelopathies, and 5 had peripheral nerve lesions accounting for their weakness. The study was conducted between February 1, 2016, and June 30, 2017. RESULTS: The median clinical McArdle sign and the 2 quantitative measures of neck flexion-induced strength reduction were greater in patients with MS than in the other groups (P<.001). Baseline strength did not confound the difference. The area under the receiver operating characteristic curve was 0.84 (95% CI, 0.75-0.93) comparing patients with MS vs healthy controls and 0.84 (95% CI, 0.75-0.93) comparing MS vs patients with other myelopathies. The 2 quantitative and 1 clinical measurement of McArdle sign by the technician who performed the quantitative testing were correlated (r=.57 and r=.58; P<.001), and in turn, the technician's and unblinded referring physician's clinical assessments were correlated (r=.58; P<.001). McArdle sign was evident in some patients who had minor disability and who were in early phases of MS. CONCLUSION: McArdle sign, when defined as greater than 10% neck flexion-induced reduction in strength, is entirely specific and 65% sensitive for a diagnosis of MS when compared with other conditions that mimic MS-associated myelopathy. It may facilitate diagnosis in certain clinical situations. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT03122873.


Assuntos
Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico , Debilidade Muscular/diagnóstico , Exame Neurológico/métodos , Exame Físico/métodos , Adulto , Estudos de Casos e Controles , Progressão da Doença , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/classificação , Análise Multivariada , Debilidade Muscular/classificação , Projetos Piloto , Curva ROC , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença
6.
JBMR Plus ; 3(5): e10119, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31131342

RESUMO

We are developing electrical approaches to treat biofilm-associated orthopedic foreign-body infection. Although we have previously shown that such approaches have antibiofilm activity, the effects on bone have not been assessed. Herein, low-amperage 200 µA fixed direct current (DC) was compared with no current, in a rat femoral foreign-body infection model. In the infected group, a platinum implant seeded with S. epidermidis biofilm (105 CFU/cm2), plus 50 µL of a 109 CFU suspension of bacteria, were placed in the femoral medullary cavity of 71 rats. One week later, rats were assigned to one of four groups: infected with no current or DC, or uninfected with no current or DC. After 2 weeks, bones were removed and subjected to histopathology, micro-computed tomography (µCT), and strength testing. Histopathology showed no inflammation or bony changes/remodeling in the uninfected no current group, and some osteoid formation in the DC group; bones from the infected no current group had evidence of inflammation without bony changes/remodeling; along with inflammation, there was moderate osteoid present in the DC group. µCT showed more cortical bone volume and density, trabecular thickness, and cancellous bone volume in the DC group compared with the no current group, for both uninfected and infected bones (p < 0.05). There was no difference in torsional strength or stiffness between the no current versus DC groups, for both infected and uninfected bones (p > 0.05). © 2018 The Authors. JBMR Plus Published by Wiley Periodicals, Inc. on behalf of the American Society for Bone and Mineral Research.

7.
J Orthop Surg Res ; 14(1): 43, 2019 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-30755223

RESUMO

BACKGROUND: Polymethylmethacrylate (PMMA) is used for local antimicrobial delivery in orthopedic infection. Oritavancin is a long half-life lipoglycopeptide with broad activity against Gram-positive bacteria. Herein, we addressed if 7.5% w/w oritavancin mixed into PMMA affects PMMA strength and whether it elutes from PMMA, compared to vancomycin. METHODS: Elution was assessed by placing an oritavancin- or vancomycin-loaded bead in a flow system with human plasma. Compressive strength of bland compared to oritavancin- or vancomycin-loaded PMMA was assessed after 0, 3, and 7 days of soaking in 1 ml of pooled normal human plasma at 37 °C, by testing to failure in axial compression using a servo-hydraulic testing machine. RESULTS: Median compressive strength on days 0, 3, and 7 for bland PMMA compared to oritavancin- or vancomycin-loaded PMMA was 80.1, 79.4, and 72.4 MPa, respectively; 93.3, 86.4, and 65.3 MPa, respectively; and 97.8, 82.7, and 65.9 MPa, respectively. Oritavancin reduced PMMA compressive strength after 3 and 7 days (P = 0.0250 and 0.0039, respectively), whereas vancomycin reduced the PMMA compressive strength after 0, 3, and 7 days (P = 0.0039, 0.0039, and 0.0062, respectively) as compared to bland PMMA. Oritavancin-loaded PMMA had higher compressive strength than vancomycin-loaded PMMA on days 3 and 7 (P = 0.0039 and 0.0062, respectively). Compressive elastic moduli were 1226, 1299, and 1394 MPa for bland PMMA; 1253, 1078, and 1245 MPa for oritavancin-loaded PMMA; and 986, 879, and 779 MPa for vancomycin-loaded PMMA on days 0, 3 and 7, respectively. Oritavancin-loaded PMMA had higher compressive elastic moduli than vancomycin-loaded PMMA on days 0 and 7 (P = 0.0250 and 0.0062, respectively). Following polymerization, 1.0% and 51.9% of the initial amount of oritavancin and vancomycin were detected, respectively. Cmax, Tmax, and AUC0-24 were 1.7 µg/ml, 2 h, and 11.4 µg/ml for oritavancin and 21.4 µg/ml, 2 h, and 163.9 µg/ml for vancomycin, respectively. CONCLUSIONS: Oritavancin-loaded PMMA had higher compressive strength than vancomycin-loaded PMMA on days 3 and 7 and higher compressive elastic moduli than vancomycin-loaded PMMA on days 0 and 7. However, proportionally less oritavancin than vancomycin eluted out of PMMA.


Assuntos
Antibacterianos/administração & dosagem , Lipoglicopeptídeos/administração & dosagem , Polimetil Metacrilato , Força Compressiva , Teste de Materiais
8.
J Shoulder Elbow Surg ; 28(1): 170-177, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30337267

RESUMO

BACKGROUND: The interosseous membrane (IOM) and distal radioulnar joint (DRUJ) provide axial stability to the forearm. Our hypothesis was that injury to these structures alters force transmission through the elbow. METHODS: A custom-designed apparatus that applies axial loads from the wrist to the elbow was used to test 10 cadaveric upper limbs under the following simulated conditions (1) intact, (2) DRUJ injury, (3) IOM injury, or (4) IOM + DRUJ injury. IOM injury was simulated by osteotomies of the IOM attachment to the radius, and DRUJ injury was simulated by distal ulnar oblique osteotomy. We applied 160 N of axial force during cyclic and functional range of forearm rotation (40o pronation/40o supination), and force, contact pressure, and contact area through the elbow joint were measured simultaneously. RESULTS: The force across the radiocapitellar joint was significantly higher in the IOM + DRUJ injury and the IOM injury groups than in the intact and DRUJ injury groups. The mean force across the radiocapitellar joint was not significantly different between the intact and DRUJ injury groups or between the IOM + DRUJ injury and the IOM injury groups. Forces across the ulnohumeral joint showed an inverse pattern to those in the radiocapitellar joint. CONCLUSIONS: These findings suggest that injury to the IOM contributes more to the disruption of the normal distribution of axial loads across the elbow than injury to the DRUJ.


Assuntos
Fenômenos Biomecânicos/fisiologia , Articulação do Cotovelo/fisiopatologia , Antebraço/fisiopatologia , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Masculino , Membranas/lesões , Traumatismos do Punho/fisiopatologia
9.
Biomaterials ; 192: 189-198, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30453215

RESUMO

Reducing rotator cuff failure after repair remains a challenge due to suboptimal tendon-to-bone healing. In this study we report a novel biomaterial with engineered tendon-fibrocartilage-bone composite (TFBC) and bone marrow-derived mesenchymal stem cell sheet (BMSCS); this construct was tested for augmentation of rotator cuff repair using a canine non-weight-bearing (NWB) model. A total of 42 mixed-breed dogs were randomly allocated to 3 groups (n = 14 each). Unilateral infraspinatus tendon underwent suture repair only (control); augmentation with engineered TFBC alone (TFBC), or augmentation with engineered TFBC and BMSCS (TFBC + BMSCS). Histomorphometric analysis and biomechanical testing were performed at 6 weeks after surgery. The TFBC + BMSCS augmented repairs demonstrated superior histological scores, greater new fibrocartilage formation and collagen fiber organization at the tendon-bone interface compared with the controls. The ultimate failure load and ultimate stress were 286.80 ± 45.02 N and 4.50 ± 1.11 MPa for TFBC + BMSCS group, 163.20 ± 61.21 N and 2.60 ± 0.97 MPa for control group (TFBC + BMSCS vs control, P = 1.12E-04 and 0.003, respectively), 206.10 ± 60.99 N and 3.20 ± 1.31 MPa for TFBC group (TFBC + BMSCS vs TFBC, P = 0.009 and 0.045, respectively). In conclusion, application of an engineered TFBC and BMSCS can enhance rotator cuff healing in terms of anatomic structure, collagen organization and biomechanical strength in a canine NWB model. Combined TFBC and BMSCS augmentation is a promising strategy for rotator cuff tears and has a high potential impact on clinical practice.


Assuntos
Fibrocartilagem/química , Células-Tronco Mesenquimais/citologia , Manguito Rotador/fisiologia , Tendões/química , Alicerces Teciduais/química , Cicatrização , Animais , Materiais Biocompatíveis/química , Osso e Ossos/química , Cães , Transplante de Células-Tronco Mesenquimais , Manguito Rotador/citologia , Engenharia Tecidual
10.
J Bone Joint Surg Am ; 100(6): e34, 2018 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-29557868

RESUMO

BACKGROUND: Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. METHODS: Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. RESULTS: The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm to 150 ± 58 mm (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). CONCLUSIONS: The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. CLINICAL RELEVANCE: This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.


Assuntos
Artrite/etiologia , Articulação do Cotovelo/fisiopatologia , Luxações Articulares/fisiopatologia , Instabilidade Articular/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Suporte de Carga/fisiologia , Cadáver , Humanos , Luxações Articulares/complicações , Instabilidade Articular/complicações , Masculino
11.
J Orthop Res ; 2018 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-29473666

RESUMO

The current method of measuring arthrofibrosis in live rabbits is critically limited. Specifically, this method involves radioactive fluoroscopy, error-prone goniometric measurements, and static joint angle outcomes that fail to approximate the compliance of tissues surrounding the joint. This study aims to validate a novel method of capturing the compliance of contracted tissues surrounding the joint without the use of fluoroscopy or animal sacrifice. Surgically induced contractures of one-hundred and eight rabbits were measured using the current standard of contracture measurement (a pulley system) as well as a newly designed dynamic load cell (DLC) device. The DLC device was highly reliable when compared to the pulley system (r = 0.907, p < 0.001). Finally, the DLC device produced joint stiffness hysteresis curves capable of approximating the compliance of stiff joint tissues, ultimately calculating a mean joint stiffness of 1.57 ± 1.31 N · m · rad-1 (range, 0.33-6.37 N · m · rad-1 ). In conclusion, the DLC device represents a valid method for measuring joint contractures. Further, the DLC device notably improves current techniques by introducing the capacity to approximate the compliance of contracted tissues in living rabbits. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

12.
J Cell Biochem ; 119(7): 5715-5724, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29388702

RESUMO

Tendon graft healing in bone tunnels for the fixation of intra-articular ligament reconstructions may limit clinical outcome by delaying healing. This study assesses the effects of hydrogel-mediated delivery of bone anabolic growth factors in a validated model of tendon-to-bone tunnel healing. Forty-five Wistar rats were randomly allocated into three groups (BMP2-treated, GSK126-treated, and placebo). All animals underwent a tendon-to-bone tunnel reconstruction. Healing was evaluated at 4 weeks by biomechanical assessment, micro-computed tomography (bone mineral density, bone volume, cross sectional area of bone tunnels), and traditional histology. Adverse events associated with the hydrogel-mediated delivery of drugs were not observed. Results of our biomechanical assessment demonstrated favorable trends in animals treated with bone anabolic factors for energy absorption (P = 0.116) and elongation (P = 0.054), while results for force to failure (P = 0.691) and stiffness (P = 0.404) did not show discernible differences. Cross sectional areas for BMP2-treated animals were reduced, but neither BMP2 nor GSK126 administration altered bone mineral density (P = 0.492) or bone volume in the bone tunnel. These results suggest a novel and positive effect of bone anabolic factors on tendon-to-bone tunnel healing. Histological evaluation confirmed absence of collagen fibers crossing the soft tissue-bone interface indicating immature graft integration as expected at this time point. Our study indicates that hydrogel-mediated delivery of BMP2 and GSK126 appears to be safe and has the potential to enhance tendon-to-bone tunnel healing in ligament reconstructions.


Assuntos
Anabolizantes/administração & dosagem , Osso e Ossos/citologia , Adesivo Tecidual de Fibrina/administração & dosagem , Tendões/citologia , Adesivos Teciduais/administração & dosagem , Cicatrização , Animais , Proteína Morfogenética Óssea 2/metabolismo , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/metabolismo , Masculino , Ratos , Ratos Wistar , Tendões/efeitos dos fármacos , Tendões/metabolismo , Microtomografia por Raio-X
13.
J Shoulder Elbow Surg ; 27(3): 530-537, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29290603

RESUMO

BACKGROUND: Forearm rotation is closely associated with the axiorotational force transmission through the elbow joint. A technique has been developed to study the transmission of force across the radiocapitellar and ulnotrochlear joints during forearm rotation. METHODS: Ten human cadaveric upper limbs were prepared on a custom-designed apparatus that permits the application of extrinsic axial loads across an intact cadaveric elbow joint. A force-sensitive transducer was inserted into the elbow joint of each cadaver. A 160 N axial force was applied to the specimen during cyclic forearm rotation while the force, contact pressure, and contact area through the elbow joint were measured. RESULTS: The mean force across the radiocapitellar joint showed no significant difference between pronation and supination (P = .3547). The radiocapitellar joint showed significantly higher contact area (P = .0001) and lower contact pressure (P = .0001) in pronation than in supination. The mean values for contact pressure, area, and force across the ulnotrochlear joint were not significantly different between supination and pronation. CONCLUSION: The contact pressure and contact area of the radiocapitellar joint in the cadaveric model changed according to forearm rotation while the force remained constant. The mean contact pressure of the radiocapitellar joint in pronation was significantly lower than that in supination because the force across it did not change significantly and its contact area decreased significantly. These findings may suggest that the pronated elbow can play an important role in protecting the radiocapitellar joint in high-impact activities like delivering punch in martial arts or falling on an outstretched arm.


Assuntos
Articulação do Cotovelo/fisiopatologia , Antebraço/fisiologia , Amplitude de Movimento Articular/fisiologia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Cotovelo , Feminino , Humanos , Masculino , Pronação , Rotação , Supinação
14.
J Shoulder Elbow Surg ; 26(10): 1794-1802, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28734719

RESUMO

HYPOTHESIS: The purposes of this study were to test the hypothesis that coronoid deficiency in the setting of posteromedial rotatory instability (PMRI) must be reconstructed to restore articular contact pressures to normal and to compare 3 different osteochondral grafts for this purpose. METHODS: After creation of a anteromedial fracture, six cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and to passively flex the elbow. Mean articular surface contact pressure data were collected and processed using TekScan sensors and software. After testing of the intact specimen (intact condition), a PMRI injury was created (PMRI condition). Testing was repeated after reconstruction of the lateral collateral ligament (LCL) (LCL-only condition), followed by reconstruction of the coronoid with 3 different osteochondral graft techniques (reconstructed conditions). RESULTS: Contact pressure was consistently significantly higher in the PMRI elbow compared with the intact, LCL-only, and reconstructed conditions (P < .006). The LCL-only elbow contact pressure was significantly higher than that of the intact and reconstructed conditions from 5° to 55° of flexion (P = .018). The contact pressure of the intact elbow was never significantly different from that of the reconstructed elbow, except at 5° of flexion (P ≤ .008). No significant difference was detected between each of the reconstructed techniques (P ≥ .15). However, the annular surface of the radial head was the only graft that yielded contact pressures not significantly different from normal at any flexion angle. CONCLUSION: Isolated reconstruction of the LCL did not restore native articular surface contact pressure, and reconstruction of the coronoid using osteochondral graft was necessary. There was no difference in contact pressures among the 3 coronoid reconstruction techniques.


Assuntos
Artroplastia/métodos , Transplante Ósseo/métodos , Fraturas Intra-Articulares/cirurgia , Instabilidade Articular/cirurgia , Fraturas da Ulna/cirurgia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Ligamentos Colaterais/cirurgia , Humanos , Masculino , Amplitude de Movimento Articular/fisiologia
15.
J Shoulder Elbow Surg ; 26(9): 1636-1643, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28689821

RESUMO

BACKGROUND: Posteromedial rotatory instability (PMRI) of the elbow consists of an anteromedial coronoid fracture with lateral collateral ligament (LCL) and posterior bundle of the medial collateral ligament (PMCL) tears. We hypothesized that the LCL tear is required for elbow subluxation/joint incongruity and that an elbow affected by an anteromedial subtype 2 coronoid fracture and a PMCL tear exhibits contact pressures different from both an intact elbow and an elbow affected by PMRI. MATERIALS AND METHODS: Six cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and to passively flex the elbow from 0° to 90° and measure joint contact pressures. After testing of the intact specimen (INTACT-elbow), an anteromedial subtype 2 coronoid fracture with a PMCL tear (COR+PMCL-elbow) and a PMRI injury (PMRI-elbow), after adding an LCL tear, were tested. The highest values of mean contact pressure were used for the comparison among the 3 groups. RESULTS: Neither subluxation nor joint incongruity was observed in the COR+PMCL-elbow. The addition of an LCL detachment consistently caused subluxation and joint incongruity. Mean contact pressures were higher in the COR+PMCL-elbow compared with the INTACT-elbow (P < .03) but lower than in the PMRI-elbow (P < .001). CONCLUSIONS: The LCL lesion in PMRI is necessary for elbow subluxation and causes marked elevations in contact pressures. Even without subluxation, the COR+PMCL-elbow showed higher contact pressures compared with the INTACT-elbow. Treatment of PMRI should be directed toward prevention of joint incongruity, whether by surgical or nonsurgical means, to prevent high articular contact pressures.


Assuntos
Ligamentos Colaterais/fisiopatologia , Articulação do Cotovelo/fisiopatologia , Instabilidade Articular/fisiopatologia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Amplitude de Movimento Articular , Lesões no Cotovelo
16.
J Biomech Eng ; 138(5): 054502, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26974192

RESUMO

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion-extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar-sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2-S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17-0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion-extension are likely robust, even when patient alignment is not perfect.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiologia , Fenômenos Mecânicos , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Fluoroscopia , Humanos , Movimento
17.
J Bone Joint Surg Am ; 97(12): 972-8, 2015 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-26085530

RESUMO

BACKGROUND: Functional restoration is the major concern after flexor tendon reconstruction in the hand. The purpose of the present study was to investigate the effects of modifying the surface of extrasynovial tendon autografts with carbodiimide-derivatized synovial fluid with gelatin (cd-SF-G) on functional outcomes of flexor tendon reconstruction using a canine model. METHODS: The second and fifth flexor digitorum profundus tendons from eleven dogs were transected and repaired in zone II. The dogs then had six weeks of free activity leading to tendon rupture and scar formation (the repair-failure phase). In the reconstruction phase, two autologous peroneus longus tendons from each dog were harvested; one tendon was coated with cd-SF-G and the other, with saline solution, as a control. A non-weight-bearing rehabilitation protocol was followed for six weeks after reconstruction. The digits were then harvested and evaluations of function, adhesion status, gliding resistance, attachment strength, cell viability, and histology were performed. RESULTS: The tendons coated with cd-SF-G demonstrated significantly lower values (mean and standard deviation) compared with the saline-solution group for work of flexion (0.63 ± 0.24 versus 1.34 ± 0.42 N-mm/deg), adhesion score (3.5 ± 1.6 versus 6.1 ± 1.3), proximal adhesion breaking force (8.6 ± 3.2 versus 20.2 ± 10.2 N), and gliding resistance (0.26 ± 0.08 versus 0.46 ± 0.22 N) (p < 0.05). There was no significant difference between the cd-SF-G and saline-solution groups (p > 0.05) in distal attachment-site strength (56.9 ± 28.4 versus 77.2 ± 36.2 N), stiffness (19 ± 7.5 versus 24.5 ± 14.5 N/mm), and compressive modulus from indentation testing (4.37 ± 1.26 versus 3.98 ± 1.24 N/mm). Histological analysis showed that tendons coated with cd-SF-G had smoother surfaces and demonstrated tendon-to-bone and tendon-to-tendon incorporation. No significant difference in viable cell count between the two groups was observed on tendon culture. CONCLUSIONS: Modification of the flexor tendon surface with cd-SF-G significantly improved digital function and reduced adhesion formation without affecting graft healing and stiffness. CLINICAL RELEVANCE: This study used native synovial fluid as a basic lubricating reagent to treat a tendon graft in vivo, a novel avenue for improving clinical outcomes of flexor tendon reconstruction. This methodology may also apply to other surgical procedures where postoperative adhesions impair function.


Assuntos
Líquido Sinovial , Tendões/cirurgia , Animais , Carbodi-Imidas/farmacologia , Cães , Gelatina , Modelos Animais , Procedimentos Ortopédicos/métodos , Propriedades de Superfície , Líquido Sinovial/efeitos dos fármacos , Tendões/transplante , Aderências Teciduais/prevenção & controle
18.
Clin J Sport Med ; 25(3): 254-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24949830

RESUMO

OBJECTIVE: To evaluate the effectiveness of a variety of neck guard brands when contacted by a sharpened hockey skate blade. DESIGN: Analytic experimental. SETTING: Laboratory. PARTICIPANTS: Neck surrogate. INTERVENTIONS: Forty-six samples of 14 different types of neck guards were tested on a custom-made laceration machine using a neck surrogate. Closed-cell polyethylene foam was placed between the neck surrogate and the protective device. MAIN OUTCOME MEASURES: The effectiveness of the neck guard was evaluated by observation of the foam after the simulated slicing action of the skate blade. Two sets of tests were performed on each device sample including low and high force. For low-force tests, initial compression loads of 100, 200, and 300 N were applied between the neck surrogate for each of 2 orientations of the blade at 45 and 90 degrees. For high-force tests, representing a more severe simulation, the applied load was increased to 600 N and a blade angle fixed at 45 degrees. All tests were performed at a blade speed of 5 m/s. RESULTS: Only 1 product, the Bauer N7 Nectech, failed during the 300-N compression tests. All of the neck guards failed during 600-N test condition except for the Skate Armor device and 1 of the 3 Reebok 11K devices. CONCLUSIONS: A skate blade angle of 45 degrees increased the likelihood of a neck laceration compared with a skate blade angle of 90 degrees due to decreased contact area. Damage to the neck guard is not an indicator of the cut resistance of a neck guard. Neck protectors with Spectra fibers were the most cut resistant. CLINICAL RELEVANCE: The study provides data for the selection of neck guards and neck guard materials that can reduce lacerations to the neck.


Assuntos
Traumatismos em Atletas/prevenção & controle , Hóquei/lesões , Lacerações/prevenção & controle , Lesões do Pescoço/prevenção & controle , Roupa de Proteção , Humanos
19.
J Shoulder Elbow Surg ; 23(4): 456-62, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24630544

RESUMO

HYPOTHESIS: Our aim was to test whether anatomically designed metallic radial head implants could better reproduce native radiocapitellar contact pressure and areas than nonanatomic implants. METHODS: The distal humerus and proximal radius from 6 cadaveric upper extremities were serially tested in supination with 100 N of compression force at 4 angles of flexion (0°, 30°, 60°, and 90°). By use of a thin flexible pressure transducer, contact pressures and areas were measured for the native radial head, an anatomic implant, a nonanatomic circular monopolar implant, and a bipolar nonanatomic implant. The data (mean contact pressure and mean contact area) were modeled using a 2-factor repeated-measures analysis of variance with P ≤ .05 considered to be significant. RESULTS: The mean contact areas for the prosthetic radial heads were significantly less than those seen with the intact radial heads at every angle tested (P < .01). The mean contact pressures increased significantly with all prosthetic radial head types as compared with the native head. The mean contact pressures increased by 29% with the anatomic prosthesis, 230% with the monopolar prosthesis, and 220% with the bipolar prosthesis. Peak pressures of more than 5 MPa were more commonly observed with both the monopolar and bipolar prostheses than with the anatomic or native radial heads. CONCLUSIONS: The geometry of radial head implants strongly influences their contact characteristics. In a direct radius-to-capitellum axial loading experiment, an anatomically designed radial head prosthesis had lower and more evenly distributed contact pressures than the nonanatomic implants that were tested.


Assuntos
Articulação do Cotovelo/fisiologia , Prótese de Cotovelo , Úmero/fisiologia , Desenho de Prótese , Rádio (Anatomia)/fisiologia , Idoso , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular
20.
J Prosthodont ; 23(5): 353-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24417233

RESUMO

PURPOSE: The goals of part 2 of the study presented here were 1) to assess whether there is a difference in failure mode of different thicknesses (2.0, 1.5, 1.0, and 0.5 mm) of anatomically standardized full contour monolithic lithium disilicate restorations for posterior teeth, and 2) to assess if there is a difference among various crown thicknesses when these restorations are subjected to dynamic load forces common for posterior teeth. MATERIALS AND METHODS: Four groups (n = 10), each with a different thickness of anatomically appropriate all-ceramic crowns, were to be tested as established from the statistical analysis of the preliminary phase. Group 1: 2.0 mm; group 2: 1.5 mm; group 3: 1.0 mm; group 4: 0.5 mm. The specimens were adhesively luted to the corresponding die, and underwent dynamic cyclic loading (380 to 390 N) completely submerged in an aqueous environment until a failure was noted by graphic recording and continuous monitoring. RESULTS: There was a statistically significant difference of the fatigue cycles to failure among four groups (p < 0.001; Kruskal-Wallis test). The mean number of cycles to fail for 2.0 mm specimens was 17 times more than the mean number of cycles to fail for 1.0 mm specimens and 1.5 times more than the mean number of cycles to fail for 1.5 mm specimens. The 0.5 mm specimens failed with one cycle of loading. A qualitative characteristic noted among the 2.0 mm specimens was wear of the area of indenter contact followed by shearing of the material and/or crack propagation. CONCLUSION: Based on the findings of this study, it may be reasonable to consider a crown thickness of 1.5 mm or greater for clinical applications of milled monolithic lithium disilicate crowns for posterior single teeth.


Assuntos
Coroas , Porcelana Dentária/química , Falha de Restauração Dentária , Condicionamento Ácido do Dente/métodos , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Ácido Fluorídrico/química , Teste de Materiais , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Preparo Prostodôntico do Dente/métodos , Água/química