1.
Comput Biol Med ; 39(6): 562-7, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19446798

RESUMO

Fetal monitoring using abdominally recorded signals (ADS) allows physicians to detect occurring changes in the well-being state of the fetus from the beginning of pregnancy. Mainly based on the fetal electrocardiogram (fECG), it provides the long-term fetal heart rate (fHR) and assessment of the fetal QRS morphology. But the fECG component in ADS is obscured by the maternal ECG (mECG), thus removal of the mECG from ADS improves fECG analysis. This study demonstrates the performance of the event-synchronous interference canceller (ESC) in mECG removal from ADS data, recorded during pregnancy and labor. Its advantage as a compensation method for extended ADS processing is discussed.


Assuntos
Algoritmos , Eletrocardiografia , Feto/fisiologia , Feminino , Monitorização Fetal/métodos , Humanos , Gravidez
2.
Biomed Tech (Berl) ; 54(2): 66-75, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19290851

RESUMO

Analysis of the fetal ECG (fECG) allows physicians to detect changes in the well-being state of the fetus. But when assessing the fECG through the abdominal signals (ADS), its very low amplitude causes a problem, as the fECG representation in the ADS is buried in a mixture of other signals with stronger energy. Different methods have been proposed in the past to extract the transabdominal fECG for instantaneous fetal heart rate (fHR) computation; four representatives of them are selected for an accurate comparison of their performance in fECG extraction and in fHR estimation. A model for the ADS including all the possible disturbances is developed within this study to generate simulated data as they are required for the quantitative comparison of the algorithms. Their performances and limits considering both the enhancement of the fECG and the ability to preserve fECG morphology are analyzed using the simulated data. The results clearly show that linear methods for maternal ECG removal provide better results with respect to the extraction of the fECG morphology. The algorithms are then tested on real ADS data recorded during labor. Finally, the advantage of considering linear methods for ADS processing is discussed.


Assuntos
Algoritmos , Cardiotocografia/métodos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Monitorização Fetal/métodos , Reconhecimento Automatizado de Padrão/métodos , Inteligência Artificial , Monitorização Fetal/instrumentação , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Biomed Tech (Berl) ; 52(1): 56-60, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17313335

RESUMO

Fetal ECG (FECG) monitoring using abdominal maternal signals is a non-invasive technique that allows early detection of changes in fetal wellbeing. Several other signal components have stronger energy than the FECG, the most important being maternal ECG (MECG) and, especially during labor, uterine EMG. This study proposes a new method to subtract MECG after detecting and removing abdominal signal segments with high-amplitude variations due to uterine contractions. The method removes MECG from abdominal signals using an approximation of the current MECG segment based on a linear combination of previous MECG segments aligned on the R-peak. The coefficients of the linear model are computed so that the squared error of the approximation over the whole current segment is minimized. Abdominal signal segments strongly affected by uterine contractions are detected by applying median filtering. The methods proposed are tested on real abdominal data recorded during labor, with FECG recorded using scalp electrodes synchronously recorded for comparison.


Assuntos
Algoritmos , Artefatos , Cardiotocografia/métodos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Frequência Cardíaca , Reconhecimento Automatizado de Padrão/métodos , Inteligência Artificial , Feminino , Humanos , Trabalho de Parto/fisiologia , Modelos Lineares , Modelos Cardiovasculares , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade