1.
J Long Term Eff Med Implants ; 16(5): 377-86, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17206932

RESUMO

The literature documents multiple reports of neurological injury resulting from both the implantation and the removal of orthopedic devices. These injuries can be easily and objectively evaluated with nerve conduction studies. This study was undertaken to derive a normative database for median and ulnar sensory conduction studies to the fourth digit. Testing was done utilizing a 14-cm antidromic technique on 192 asymptomatic subjects with no risk factors for neuropathy. The subjects were studied bilaterally. Onset latency, peak latency, onset-to-peak amplitude, peak-to-peak amplitude, rise time, and duration were recorded. Increasing age and body mass index were associated with decreasing amplitudes and area. No other demographic factors correlated with differences in waveform measurements. Mean onset latency was 2.7 +/- 0.3 ms for the median nerve and 2.6 +/- 0.2 for the ulnar nerve. Mean peak latency was 3.4 +/- 0.3 ms for the median nerve and 3.3 +/- 0.3 ms for the ulnar nerve. Mean onset-to-peak amplitude was 21 +/- 12 muV for the median nerve and 23 +/- 12muV for the ulnar nerve. Mean peak-to-peak amplitude was 34 +/- 20 muV for the median nerve and 36 +/- 23 muV for the ulnar nerve. Mean area was 25 +/- 17 nVs for the median nerve and 28 +/- 19 nVs for the ulnar nerve. Mean rise time was 0.7 +/- 0.1 ms for the median nerve and 0.7 +/- 0.2 ms for the ulnar nerve. Mean duration was 1.9 +/- 0.4 ms for the median nerve and 1.9 +/- 0.5 ms for the ulnar nerve. The mean difference in onset and peak latency between the median and ulnar nerves (median minus ulnar) was 0.1 +/- 0.2 ms. The upper limit of normal difference of median greater than ulnar onset and peak latency was 0.5 ms. The upper limit of normal difference of ulnar greater than median onset latency was 0.2 ms (0.3 ms for peak latency). The upper limit of normal drop in median peak-to-peak amplitude from one side to the other was 56%. For the ulnar nerve this value was 73%.

2.
J Long Term Eff Med Implants ; 16(5): 387-94, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17206933

RESUMO

There are multiple reports of neurological injury from both the implantation and the removal of devices utilized in orthopedics. Nerve conduction studies can be a valuable tool in evaluating the acuity, severity, and prognosis of these injuries, as well as in tracking their course. This study was undertaken in an effort to create a large normative database for examining median and radial sensory nerve conduction studies to the first digit. An antidromic technique was employed utilizing a 10-cm distance between the stimulating and recording electrodes. Two hundred three asymptomatic volunteers were tested. Onset latency, peak latency, onset-to-peak amplitude, peak-to-peak amplitude, area, rise time, and duration of the waveforms were measured. Males, older subjects, and those with higher body mass index (BMI) were found to have lower amplitude and area on the median nerve studies. Age was the only variable which demonstrated significant correlation with differing results on the radial nerve studies. Mean onset latencies were 2.1 +/- 0.2 ms for the median nerve and 2.0 +/- 0.2 ms for the radial nerve. Mean peak latencies were 2.7 +/- 0.2 ms for the median nerve and 2.6 +/- 0.2 ms for the radial nerve. Mean peak-to-peak amplitude for the median nerve was 45 +/- 24 muV and for the radial nerve was 12 +/- 9 muV. The upper limit of normal difference in median-versus-radial onset latency was 0.5 ms (0.6 ms for peak latency). The upper limit of normal difference in radial-minus-median onset latency was 0.3 ms (0.4 ms for peak latency).

3.
J Long Term Eff Med Implants ; 16(5): 401-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17206935

RESUMO

There are multiple reports of peripheral nerve injury following the implantation or removal of surgical hardware. Electrodiagnostic testing can be useful in assessing the chronicity, severity, and recovery of such a nerve injury. The purpose of this study is to establish a normative data set to allow for comparison of median and ulnar antidromic sensory peak-to-peak amplitude values. Median and ulnar antidromic sensory studies to digits 3 and 5 are commonly performed in electrodiagnosis to aid in the diagnosis of a variety of clinical conditions. Numerous studies have examined normal latency and amplitude values for these studies. To our knowledge there has been one other study that compared the relationship between median and ulnar sensory amplitude results taken from the same limb. That study had limited generalizability to the population at large. One hundred-nineteen volunteers were tested with antidromic sensory technique to digits 3 and 5 at 14-cm stimulation distance. Peak latency and peak-to-peak amplitude were recorded. Possible relationships between age, gender, height, weight, BMI, and median and ulnar amplitude were examined through simple linear regressions. Age, weight, height, and BMI were all found to negatively correlate with both median and ulnar amplitude. Female subjects were found to have statistically greater median and ulnar amplitudes than male subjects. Factors were said to be statistically significant at the P