Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Environ Radioact ; 231: 106562, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33667829

RESUMO

A new empirical method for in situ determination of the inventory of 137Cs in soil (ACs, kBq m-2) at grasslands and forests using a field-portable NaI(Tl) scintillation spectrometer-dosimeter was developed. The method is based on evaluation of the ambient dose equivalent build-up factor. The practical implementation of the new method with the spectrometer-dosimeter does not require a priori knowledge of the vertical distribution of 137Cs in soil. Moreover, the method allows assessing a value of the mean migration depth of 137Cs in soil (Z) in terms of g cm-2. The 95% confidence interval for the mean value of the conversion coefficients from the ambient dose equivalent build-up factor to ACs and to Z is less than 10%. The new method has been developed and verified using published data that where obtained at territories in Russia and Belarus heavily contaminated with 137Cs (ACs > 37 kBq m-2) due to the Chernobyl accident. Therefore, the survey of less contaminated areas requires additional validation of this method.


Assuntos
Monitoramento de Radiação , Poluentes Radioativos do Solo , Radioisótopos de Césio/análise , Dosímetros de Radiação , República de Belarus , Federação Russa , Solo , Poluentes Radioativos do Solo/análise
2.
Radiat Res ; 195(3): 253-264, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347576

RESUMO

With the use of ionizing radiation comes the risk of accidents and malevolent misuse. When unplanned exposures occur, there are several methods which can be used to retrospectively reconstruct individual radiation exposures; biological methods include analysis of aberrations and damage of chromosomes and DNA, while physical methods rely on luminescence (TL/OSL) or EPR signals. To ensure the quality and dependability of these methods, they should be evaluated under realistic exposure conditions. In 2019, EURADOS Working Group 10 and RENEB organized a field test with the purpose of evaluating retrospective dosimetry methods as carried out in potential real-life exposure scenarios. A 1.36 TBq 192Ir source was used to irradiate anthropomorphic phantoms in different geometries at doses of several Gy in an outdoor open-air geometry. Materials intended for accident dosimetry (including mobile phones and blood) were placed on the phantoms together with reference dosimeters (LiF, NaCl, glass). The objective was to estimate radiation exposures received by individuals as measured using blood and fortuitous materials, and to evaluate these methods by comparing the estimated doses to reference measurements and Monte Carlo simulations. Herein we describe the overall planning, goals, execution and preliminary outcomes of the 2019 field test. Such field tests are essential for the development of new and existing methods. The outputs from this field test include useful experience in terms of planning and execution of future exercises, with respect to time management, radiation protection, and reference dosimetry to be considered to obtain relevant data for analysis.


Assuntos
Doses de Radiação , Monitoramento de Radiação/métodos , Radiação Ionizante , Humanos , Radioisótopos de Irídio/efeitos adversos , Método de Monte Carlo , Imagens de Fantasmas , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiometria/métodos
3.
Sci Rep ; 10(1): 21887, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33318497

RESUMO

The pure alpha emitter 148Gd may have a significant radiological impact in terms of internal dose to exposed humans in case of accidental releases from a spallation source using a tungsten target, such as the one to be used in the European Spallation Source (ESS). In this work we aim to present an approach to indirectly estimate the whole-body burden of 148Gd and the associated committed effective dose in exposed humans, by means of high-resolution gamma spectrometry of the gamma-emitting radiogadolinium isotopes 146Gd and 153Gd that are accompanied by 148Gd generated from the operation of the tungsten target. Theoretical minimum detectable whole-body activity (MDA) and associated internal doses from 148Gd are calculated using a combination of existing biokinetic models and recent computer simulation studies on the generated isotope ratios of 146Gd/148Gd and 153Gd/148Gd in the ESS target. Of the two gamma-emitting gadolinium isotopes, 146Gd is initially the most sensitive indicator of the presence of 148Gd if whole-body counting is performed within a month after the release, using the twin photo peaks of 146Gd centered at 115.4 keV (MDA < 1 Bq for ingested 148Gd, and < 25 Bq for inhaled 148Gd). The corresponding minimum detectable committed effective doses will be less than 1 µSv for ingested 148Gd, but substantially higher for inhaled 148Gd (up to 0.3 mSv), depending on operation time of the target prior to the release. However, a few months after an atmospheric release, 153Gd becomes a much more sensitive indicator of body burdens of 148Gd, with a minimum detectable committed effective doses ranging from 18 to 77 µSv for chronic ingestion and between 0.65 to 2.7 mSv for acute inhalation in connection to the release. The main issue with this indirect method for 148Gd internal dose estimation, is whether the primary photon peaks from 146 and 153Gd can be detected undisturbed. Preliminary simulations show that nuclides such as 182Ta may potentially create perturbations that could impair this evaluation method, and which impact needs to be further studied in future safety assessments of accidental target releases.

4.
J Environ Radioact ; 214-215: 106168, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32063294

RESUMO

The aim of this study was to perform a preliminary assessment of the expected effective dose rate from external exposure to an adult individual staying at that part of the radioactively contaminated territory of the Vetka district of the Gomel region of the Republic of Belarus, from where residents had been resettled after the Chernobyl accident. For this assessment, in summer 2016 and 2018 soil samples were taken from 19 sites located in forests (7 plots), virgin meadows (4 plots), cultivated meadows (6 plots) and vegetable gardens (2 plots), with the subsequent estimation of the inventory and vertical distribution of 137Cs in the soil. The values of 137Cs inventory in the soil ranged from 452 to 1620 kBq m-2 (mean = 904 kBq m-2, median = 964 kBq m-2). The results of the measurement of soil samples were used to calculate values of the air kerma rate, normalized to the inventory of radioactive caesium in the soil. On average, the normalized indicator of the air kerma rate from the man-made source was higher in forests (1.13 nGy h-1 per kBq m-2) compared to virgin meadows (0.95 nGy h-1 per kBq m-2). Normalized air kerma rate in cultivated meadows and vegetable gardens was approximately two times lower than the corresponding indicator for virgin meadows. Using a field gamma spectrometer-dosemeter, ambient dose equivalent rate of gamma radiation in the air was measured at the surveyed sites and the contributions of the technogenic and natural components to the dose rate were estimated. Additionally, such measurements were performed on asphalted surfaces (5 sites) and inside two wooden houses. The measured values of the total ambient dose equivalent rate at a height of 1 m above the ground, asphalted surface or house floor varied from 160 to 2260 nSv h-1. The lowest levels were recorded over asphalted surfaces and inside houses, and the highest ones at forest and virgin meadow sites. The contribution of the technogenic component to the total dose rate varied from 61.9% to 98.8% (mean = 88.9%; n = 26). The effective dose of anthropogenic radiation calculated from the results of in situ measurements in a forest, virgin meadow, cultivated meadow, kitchen garden, asphalted area and house was 0.59, 0.80, 0.34, 0.29, 0.06 and 0.06 µSv h-1, respectively. Similar values for land plots were calculated based on ex situ analysis of soil samples. It can be expected that, starting from 2020, the average effective external dose of a person staying in the resettlement zone of the Vetka district will not exceed 1 mSv year-1.


Assuntos
Monitoramento de Radiação , Radioisótopos de Césio , Raios gama , Humanos , República de Belarus , Poluentes Radioativos do Solo
5.
Radiat Prot Dosimetry ; 174(1): 1-5, 2017 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-26994095

RESUMO

The possibility of using ordinary household table salt for dosimetry is suggested by its high sensitivity to ionising radiation, which generates a readout of optically stimulated luminescence (OSL). However, to exploit this finding for retrospective human dosimetry, it would be needed to find salt in close proximity to the exposed individual. Finding salty snacks frequently tucked into handbags, backpacks or pockets seemed to be a possibility; these items therefore became the test materials of the present study. The aluminium or cardboard packages used to exclude the moisture that makes crisps and nuts go soft and stale also helps to retain the induced OSL signal. Therefore, different snacks, either their salt component alone or mixed with the snack, are exposed to ionising radiation and then were assessed for their dosimetric properties. The results indicate the feasibility of using some salty snacks for dosimetry, with a minimum detectable dose as low as 0.2 mGy.


Assuntos
Monitoramento de Radiação , Radiometria , Lanches , Cloreto de Sódio , Estudos de Viabilidade , Humanos , Doses de Radiação , Estudos Retrospectivos , Dosimetria Termoluminescente
6.
Radiat Prot Dosimetry ; 173(1-3): 223-232, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27885093

RESUMO

In 2009-2014, dose surveys aimed to collect adult patient data and parameters of most common radiographic examinations were performed in six Russian regions. Typical patient doses were estimated for the selected examinations both in entrance surface dose and in effective dose. 75%-percentiles of typical patient effective dose distributions were proposed as preliminary regional diagnostic reference levels (DRLs) for radiography. Differences between the 75%-percentiles of regional typical patient dose distributions did not exceed 30-50% for the examinations with standardized clinical protocols (skull, chest and thoracic spine) and a factor of 1.5 for other examinations. Two different approaches for establishing national DRLs were evaluated: as a 75%-percentile of a pooled regional sample of patient typical doses (pooled method) and as a median of 75%-percentiles of regional typical patient dose distributions (median method). Differences between pooled and median methods for effective dose did not exceed 20%. It was proposed to establish Russian national DRLs in effective dose using a pooled method. In addition, the local authorities were granted an opportunity to establish regional DRLs if the local radiological practice and typical patient dose distributions are significantly different.


Assuntos
Doses de Radiação , Radiologia , Adulto , Humanos , Radiografia , Valores de Referência , Federação Russa , Coluna Vertebral , Inquéritos e Questionários
7.
Radiat Prot Dosimetry ; 169(1-4): 365-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26940437

RESUMO

Positron emission tomography combined with computed tomography (PET/CT) is a quantitative technique used for diagnosing various diseases and for monitoring treatment response for different types of tumours. However, the accuracy of the data is limited by the spatial resolution of the system. In addition, the so-called partial volume effect (PVE) causes a blurring of image structures, which in turn may cause an underestimation of activity of a structure with high-activity content. In this study, a new phantom, MADEIRA (Minimising Activity and Dose with Enhanced Image quality by Radiopharmaceutical Administrations) for activity quantification in PET and single photon emission computed tomography (SPECT) was used to investigate the influence on the PVE by lesion size and tumour-to-background activity concentration ratio (TBR) in four different PET/CT systems. These measurements were compared with data from measurements with the NEMA NU-2 2001 phantom. The results with the MADEIRA phantom showed that the activity concentration (AC) values were closest to the true values at low ratios of TBR (<10) and reduced to 50 % of the actual AC values at high TBR (30-35). For all scanners, recovery of true values became closer to 1 with an increasing diameter of the lesion. The MADEIRA phantom showed good agreement with the results obtained from measurements with the NEMA NU-2 2001 phantom but allows for a wider range of possibilities in measuring image quality parameters.


Assuntos
Artefatos , Aumento da Imagem/instrumentação , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Tumoral
8.
Radiat Prot Dosimetry ; 169(1-4): 240-4, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26743258

RESUMO

Computed tomography (CT) is often a justified diagnostic tool, but is also associated with high exposure of the patients. Due to the rapid increase in the number of CT units and thus the availability of CT examinations in Russia, there is a growing need for optimisation within this field. In order to develop proper optimisation procedures for CT, the two regions St. Petersburg and Belgorod of Russia were chosen, representing an urban and a rural region, respectively. In 2014, a survey was conducted of the parameters applied in CT examinations in these regions, and the results show that the highest effective doses were observed for investigations of abdomen, reaching up to 137 mSv, and pelvic CT examinations, reaching up to 58 mSv, both with contrast agents. The dose distributions were approximately log-normal, and for the majority of the examinations, the 75th percentiles of the CT dose distributions in the Belgorod region were higher than observed in St. Petersburg. The aim of the current project is primarily to define and implement diagnostic reference levels as a part of the process of optimisation of CT examinations in Russia.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Radiologia/métodos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Cavidade Abdominal , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exame Físico , Serviços de Saúde Rural , Federação Russa , Serviços Urbanos de Saúde
9.
Radiat Prot Dosimetry ; 169(1-4): 232-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26769906

RESUMO

An anthropomorphic phantom study was carried out in 2013-14 in two hospitals, one located in Russia (Mariinsky Hospital, Saint Petersburg) and the other in Sweden (Skåne University Hospital, Malmö). The aim of the study was to investigate the possibilities to reduce the patient dose from digital X-ray chest screening examinations. The existing chest imaging protocols were adjusted by changing the tube voltage, total filtration and grid in order to determine the most dose-effective combination of the examination parameters. It was possible to achieve up to 50 % dose-area product (DAP) and 30 % effective dose reduction by raising the tube voltage from 100 to 125 or 150 kV, and simultaneously decrease the total filtration to the minimum allowed by the X-ray unit (3 mm Al). The absence of a grid allowed to further reduce the DAP and effective dose by up to 80 %. Comparison between Russian and Swedish X-ray units showed the same trend in DAP and effective dose reduction, but the absolute dose values were lower by almost a factor of 10 for the Swedish units due to different image receptors and automatic exposure control settings.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica/métodos , Radiometria/métodos , Adulto , Antropometria , Análise Custo-Benefício , Filtração , Humanos , Masculino , Proteção Radiológica/métodos , Federação Russa , Suécia , Raios X
10.
J Environ Radioact ; 149: 144-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26245870

RESUMO

Radionuclides from the 1986 Chernobyl accident were released and dispersed during a limited period of time, but under widely varying weather conditions. As a result, there was a high geographical variation in the deposited radioactive fallout per unit area over Europe, depending on the released composition of fission products and the weather during the 10 days of releases. If the plume from Chernobyl coincided with rain, then the radionuclides were unevenly distributed on the ground. However, large variations in the initial fallout also occurred locally or even on a meter scale. Over the ensuing years the initial deposition may have been altered further by different weathering processes or human activities such as agriculture, gardening, and decontamination measures. Using measurements taken more than two decades after the accident, we report on the inhomogeneous distribution of the ground deposition of the fission product (137)Cs and its influence on the dose rate 1 m above ground, on both large and small scales (10ths of km(2) - 1 m(2)), in the Gomel-Bryansk area close to the border between Belarus and Russia. The dose rate from the deposition was observed to vary by one order of magnitude depending on the size of the area considered, whether human processes were applied to the surface or not, and on location specific properties (e.g. radionuclide migration in soil).


Assuntos
Radioisótopos de Césio/análise , Doses de Radiação , Cinza Radioativa/análise , Poluentes Radioativos do Solo/análise , Acidente Nuclear de Chernobyl , Humanos , Monitoramento de Radiação , República de Belarus , Federação Russa
11.
Sci Total Environ ; 409(22): 4811-7, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21906781

RESUMO

A Nordic-Soviet programme was initiated in 1990 to evaluate the external and internal radiation exposure of the inhabitants of several villages in the Bryansk region of Russia. This area was one of the number of areas particularly affected by the nuclear accident at the Chernobyl Nuclear Power Plant in 1986. Measurements were carried out yearly until 1998 and after that more irregularly; in 2000, 2006 and 2008 respectively. The effective dose estimates were based on individual thermoluminescent dosemeters and on in vivo measurements of the whole body content of (137)Cs (and (134)Cs during the first years of the programme). The decrease in total effective dose during the almost 2 decade follow-up was due to a continuous decrease in the dominating external exposure and a less decreasing but highly variable exposure from internal irradiation. In 2008, the observed average effective dose (i.e. the sum of external and internal exposure) from Chernobyl (137)Cs to the residents was estimated to be 0.3mSv y(-1). This corresponds to 8% of the estimated annual dose in 1990 and to 1% of the estimated annual dose in 1986. As a mean for the population group and for the period of the present study (2006-2008), the average yearly effective dose from Chernobyl cesium was comparable to the absorbed dose obtained annually from external exposure to cosmic radiation plus internal exposure to naturally occurring radionuclides in the human body. Our data indicate that the effective dose from internal exposure is becoming increasingly important as the body burdens of Chernobyl (137)Cs are decreasing more slowly than the external exposure. However, over the years there have been large individual variations in both the external and internal effective doses, as well as differences between the villages investigated. These variations and differences are presented and discussed in this paper.


Assuntos
Acidente Nuclear de Chernobyl , Exposição Ambiental/análise , Monitoramento de Radiação/estatística & dados numéricos , Carga Corporal (Radioterapia) , Radioisótopos de Césio/análise , Humanos , Monitoramento de Radiação/métodos , População Rural , Federação Russa , Dosimetria Termoluminescente , Fatores de Tempo
12.
Radiat Prot Dosimetry ; 144(1-4): 584-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21273199

RESUMO

The single-aliquot regenerative-dose (SAR) protocols used in retrospective dosimetry for optically stimulated luminescence measurements have been mainly developed for archaeological and geological dating of quartz and feldspar. The aim in this study is to find a read-out protocol that can generate the most reproducible signal for household salt (NaCl) at absorbed doses below 100 mGy. The relation between the reproducibility of the signal, in terms of the ratio between given absorbed dose and SAR-calculated dose, and parameters such as test-dose pre-heat temperature has been studied. It was found that a temperature of 200 °C yielded the best reproducibility in the SAR-calculated dose, which is a somewhat higher pre-heat temperature than what is used for dating of quartz.


Assuntos
Medições Luminescentes/instrumentação , Radiometria/instrumentação , Calibragem , Temperatura Alta , Humanos , Medições Luminescentes/métodos , Quartzo , Monitoramento de Radiação/instrumentação , Radiação Ionizante , Radiometria/métodos , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Cloreto de Sódio/química , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...