Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 73(21): 5328-33, 2001 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11721937

RESUMO

The susceptibility of segmented polyurethanes (SPUs) to in vivo oxidative cleavage and hydrolysis constitutes a drawback in the use of these materials in the fabrication of implantable devices. The introduction of poly(dimethylsiloxane) (PDMS) groups into the polymer main chain has been previously reported to enhance the stability of SPUs. Herein, we evaluated the use of BioSpan-S, a silicone-modified SPU, in the design of membranes for cation-selective electrodes. The resulting electrodes exhibited good potentiometric response with all of the tested ionophores (valinomycin, sodium ionophore X, and nonactin). The obtained selectivity coefficients meet the selectivity requirements for the determination of sodium and potassium in blood. Moreover, as reflected by SEM studies, membranes prepared with BioSpan-S showed less adhesion of platelets than membranes prepared with conventional poly(vinyl chloride) (PVC). These results lead to the conclusion that BioSpan-S would be an appropriate candidate for the fabrication of implantable ion-selective electrodes.


Assuntos
Eletrodos Seletivos de Íons/efeitos adversos , Membranas Artificiais , Poliuretanos/metabolismo , Silicones/metabolismo , Trombose/etiologia , Trombose/prevenção & controle , Materiais Revestidos Biocompatíveis/metabolismo , Dimetilpolisiloxanos/metabolismo , Eletrodos Implantados/efeitos adversos
2.
Anal Chem ; 72(21): 5295-9, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11080879

RESUMO

Ionophore topology has a profound effect on the behavior of ion-selective electrodes. This is demonstrated with a new class of ionophores that incorporates aminochromenone moieties linked through urea spacers to different scaffolds that preorganize the ionophore binding cleft into tripodal topologies. Tris(2-aminoethylamine) and cis-1,3,5-tris(aminomethyl)cyclohexane were employed as the scaffolds. The two differ in their rigidity and in the size of ionophore cavity that they create. The electrodes based on the ionophore that incorporates the tris(2-aminoethylamine) scaffold show anti-Hofmeister behavior with an improved selectivity for sulfate. In contrast, the ionophore with the cis-1,3,5-tris(aminomethyl)cyclohexane scaffold exhibits a more Hofmeister-like response.


Assuntos
Ânions/análise , Eletrodos , Ionóforos/química , Sulfatos/análise , Estrutura Molecular , Potenciometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...