Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circulation ; 53(6): 957-60, 1976 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1269131

RESUMO

Quantitative Doppler ultrasonographic flow velocity determinations are reported from 39 normal control subjects and 80 patients with angiographically documented peripheral arterial disease, in whom femoral, posterior tibial and dorsalis pedis arteries were studied. The mean control values of the most useful parameters were: femoral artery: peak forward velocity (PFV) cm/sec: 40.7 +/- 10.9, deceleration (Dec.) cm/sec2:250.9 +/- 60.0, peak/mean velocity (P/MV): 4.8 +/- 1.6; posterior tibial artery: PFV: 16.0 +/- 10.0, Dec.: 129.8 +/- 75.7, P/MV: 4.8 +/- 2.5; dorsalis pedis artery: PFV: 168 +/- 5.7, Dec.: 137.9 +/- 54.5, P/MV: 6.0 +/- 4.1. The values of these measurements in the patients with arterial occlusive disease were all significantly lower, and also permitted distinguishing those with multilevel disease from those with a single site of occlusion. Quantitative evaluation of the Doppler ultrasonogram permits obtaining detailed functional information on the degree of arterial flow impairment in patients with peripheral arterial occlusive disease.


Assuntos
Arteriopatias Oclusivas/fisiopatologia , Velocidade do Fluxo Sanguíneo , Perna (Membro)/irrigação sanguínea , Ultrassom , Adulto , Estenose da Valva Aórtica/fisiopatologia , Artérias/fisiopatologia , Artéria Femoral/fisiopatologia , Pé/irrigação sanguínea , Hemodinâmica , Humanos
2.
Ann Surg ; 181(4): 412-7, 1975 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1130859

RESUMO

A new centrifugal blood pump system has been developed for left ventricular bypass by the addition of non-thrombogenic blood surface materials and an ultrathin-walled cannula for the retrograde cannulation of the left ventricle. Partial LV bypass at 3 to 6 L/min was undertaken in 55 calves without thoracotomy. In 20 it was continued for 24 hours, with 13 survivors who were eventually sacrificed. Eleven of the last 14 experiments were completed without mishap. Heparin was employed only during pump insertion. Hematologic changes were limited to moderate platelet depression, and tolerable hemolysis (average serum level 21 mg% in the last 13 experiments). Normal clotting parameters and the absence of significant fibrin split product formation correlated with the absence of gross thrombosis and few minor renal emboli observed at autopsy. This pump system appears to have several advantages over previously described equipment for LV bypass.


Assuntos
Circulação Assistida/instrumentação , Animais , Circulação Assistida/efeitos adversos , Circulação Assistida/métodos , Contagem de Células Sanguíneas , Plaquetas , Pressão Sanguínea , Bovinos , Fibrinogênio/análise , Hematócrito , Hemoglobinas/análise , Hemólise , Contagem de Leucócitos , Oxiemoglobinas/análise , Tempo de Protrombina , Tromboembolia/etiologia , Tromboplastina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...