Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Phys Med Biol ; 65(24)2020 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-33086211

RESUMO

Metal artefacts in PET/CT images hamper diagnostic accuracy in head and neck cancer (HNC). The aim of this study is to characterise the clinical effects of metal artefacts on PET/CT in HNC and to inform decision-making concerning implementation of MAR techniques. We study a combined dual energy CT and inpainting-based metal artefact reduction (DECT-I-MAR) technique for PET/CT in three settings: (A) A dental phantom with a removable amalgam-filled tooth to evaluate the PET error in comparison to a known reference. (B) PET-positive patients with metallic implants to demonstrate the relationship between CT metal artefacts and PET error. (C) Metabolic tumour volumes delineated in PET-positive patients with metal implants to evaluate the clinical impact. In (A) DECT-I-MAR reduced the PET error significantly. In (B) we demonstrate an increasing PET error with increasing CT artefact severity in patients. In (C) it is shown that the presence of artefacts in the same axial slices as the tumour significantly decreases biomarker stability and increase delineation variability. This work shows the practical feasibility of DECT-I-MAR-based PET/CT imaging, and indicates a positive clinical impact of using the technique routinely for HNC patients. The impact of CT artefacts on PET is considerable, especially in workflows where quantitative PET biomarkers and tumour volumes are used. In such cases, and for patients with tumours in proximity of metals, we recommend that a MAR technique for PET/CT is employed.


Assuntos
Artefatos , Neoplasias de Cabeça e Pescoço , Algoritmos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X/métodos
2.
Pediatr Blood Cancer ; 61(4): 717-22, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24660228

RESUMO

BACKGROUND: The use of radiotherapy (RT) is debated for pediatric patients with Hodgkin lymphoma (HL) due to the late effects of treatment. Radiation doses to the thyroid, heart, lungs, and breasts are compared with the extensive mantle field (MF), Involved Field RT(IFRT), Modified IFRT (mIFRT), and Involved Node RT (INRT) and the risk of radiation-induced cardiovascular disease, secondary cancers, and the corresponding Life Years Lost (LYL) is estimated with each technique. PROCEDURE: INRT, mIFRT, IFRT, and MF plans (20 and 30 Gy) were simulated for 10 supradiaphragmatic, clinical stage I­II classical HL patients <18 years old, total of 4 x 2 plans for each patient. The lifetime excess risks of cardiac morbidity, cardiac mortality, lung, breast, and thyroid cancer with each technique were estimated. The estimated excess risks attributable to RT were based on HL series with long-term follow-up, treating death from other causes as competing risks. The corresponding LYL were derived from the estimated excess risks. Statistical analyses were performed with repeated measures ANOVA. RESULTS: Both a reduction in field size and in prescribed radiation dose significantly lowered the estimated dose to the heart, lungs, breasts, and thyroid compared to past,extended fields, even for patients with mediastinal disease. This translated into a significantly reduced estimated risk of cardiovascular disease, secondary cancers, and LYL. CONCLUSIONS: Involved Node Radiotherapy should be considered for pediatric patients with Hodgkin lymphoma since it is estimated to substantially lower the risk of severe long-term complications.


Assuntos
Doença de Hodgkin/complicações , Linfonodos/efeitos da radiação , Segunda Neoplasia Primária/etiologia , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador/efeitos adversos , Radioterapia/efeitos adversos , Adolescente , Mama/efeitos da radiação , Criança , Feminino , Seguimentos , Coração/efeitos da radiação , Doença de Hodgkin/radioterapia , Humanos , Pulmão/efeitos da radiação , Masculino , Órgãos em Risco , Prognóstico , Medição de Risco , Glândula Tireoide/efeitos da radiação
4.
Br J Radiol ; 85(1017): e654-60, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22919015

RESUMO

OBJECTIVES: In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design. METHODS: 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SD(trans)) and craniocaudal (CC) direction (SD(cc)) separately. Concordance indexes and volume deviations were also calculated. RESULTS: Median tumour volume was 13.0 cm(3), ranging from 0.3 to 60.4 cm(3). The mean SD(trans) was 0.15 cm (SD 0.08 cm) and the overall mean SD(cc) was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SD(trans) than tumours surrounded by lung tissue. CONCLUSIONS: The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours.


Assuntos
Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Radiocirurgia , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Strahlenther Onkol ; 188(8): 671-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22580623

RESUMO

PURPOSE: Methods to estimate the likely origin of recurrences after radiation therapy for head and neck squamous cell carcinoma are compared. METHODS AND MATERIALS: A total of 25 patients meeting the following inclusion criteria were randomly selected: curatively intended intensity-modulated radiotherapy planned on a positron emission tomography-computed tomography (PET/CT) scan during the period 2005-2009; squamous cell carcinoma in the oral cavity, pharynx or larynx; complete clinical response followed by locoregional recurrence; and a CT scan at recurrence before any salvage therapy. Exclusion criteria were previous cancer in the area, surgery prior to radiotherapy, or a synchronous cancer. Three methods of estimating focal points of recurrence origin and two volume overlap methods assigning the recurrences to the most central target volumes encompassing at least 50% or 95% of the recurrence volumes were tested. Treatment planning and recurrence scans were rigid and deformable co-registered in order to transfer focal points to the treatment planning scan. Double determinations of all volumes, points, and co-registrations were made. RESULTS: The volume overlap methods assigned the recurrences to significantly more peripheral target volumes than focal methods (p < 0.0001 for all comparisons of 95% overlap vs. focal methods, p < 0.028 for all comparisons of 50% overlap vs. focal methods). Repeated registrations of the same point had higher reproducibility with deformable registration than with rigid registration (median distance 0.31 vs. 0.35 cm, p = 0.015). No significant differences were observed among the focal methods. CONCLUSION: Significant differences between methods were found which may affect strategies to improve radiotherapy based on pattern of failure analyses.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Recidiva Local de Neoplasia/radioterapia , Neoplasias Primárias Desconhecidas/radioterapia , Neoplasias Otorrinolaringológicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Quimiorradioterapia , Terapia Combinada , Fracionamento da Dose de Radiação , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/patologia , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/cirurgia , Masculino , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/patologia , Neoplasias Bucais/radioterapia , Neoplasias Bucais/cirurgia , Imagem Multimodal , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Neoplasias Primárias Desconhecidas/diagnóstico por imagem , Neoplasias Primárias Desconhecidas/patologia , Neoplasias Primárias Desconhecidas/cirurgia , Neoplasias Otorrinolaringológicas/diagnóstico por imagem , Neoplasias Otorrinolaringológicas/patologia , Neoplasias Otorrinolaringológicas/cirurgia , Neoplasias Faríngeas/diagnóstico por imagem , Neoplasias Faríngeas/patologia , Neoplasias Faríngeas/radioterapia , Neoplasias Faríngeas/cirurgia , Tomografia por Emissão de Pósitrons , Dosagem Radioterapêutica , Terapia de Salvação , Carcinoma de Células Escamosas de Cabeça e Pescoço , Tomografia Computadorizada por Raios X , Carga Tumoral
6.
Ann Oncol ; 23(9): 2277-2282, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22357250

RESUMO

BACKGROUND: The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer. PATIENTS AND METHODS: A total of 103 consecutive patients with newly diagnosed operable breast cancer with tumors ≥2 cm were independently examined preoperatively with conventional assessment (mammography, breast/axillary ultrasound, chest X-ray and blood samples) and PET/CT with no prior knowledge of the other. RESULTS: PET/CT identified a primary tumor in all but three patients (97%). PET/CT solely detected distant metastases (ovary, bones and lung) in 6 patients and new primary cancers (ovary, lung) in another two patients, as well as 12 cases of extra-axillary lymph node involvement. In 15 patients (15%), extra-axillary malignancy was detected by PET/CT only, leading to an upgrade of initial staging in 14% (14/103) and ultimately a modification of planned treatment in 8% (8/103) of patients. CONCLUSIONS: PET/CT is a valuable tool to provide information on extra-axillary lymph node involvement, distant metastases and other occult primary cancers. Preoperative (18)F-fluorodeoxyglucose-PET/CT has a substantial impact on initial staging and on clinical management in patients with early-stage breast cancer with tumors ≥2 cm.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Cuidados Pré-Operatórios , Tomografia Computadorizada por Raios X , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/secundário , Carcinoma Ductal de Mama/cirurgia , Carcinoma Lobular/secundário , Carcinoma Lobular/cirurgia , Diagnóstico Diferencial , Feminino , Fluordesoxiglucose F18 , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
8.
Gynecol Oncol ; 116(3): 395-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20042226

RESUMO

OBJECTIVE: To investigate if the use of diagnostic FDG-PET/CT leads to stage migration in patients with advanced ovarian cancer and to evaluate the prognostic significance of FDG-PET/CT. METHODS: From September 2004 to August 2007, 201 patients with a Risk of Malignancy Index (RMI) >150 based on serum CA-125, ultrasound examinations and menopausal state, underwent PET/CT within 2 weeks prior to standard surgery/debulking of a pelvic tumor. On 15 August, 2009 overall survival and prognostic variables were analysed in 66 ovarian cancer patients (64 stage III and 2 stage IV). RESULTS: Median follow-up was 30.2 months; median age was 62.5 years (range 35-85 years); 97% (64/66) had a performance status

Assuntos
Fluordesoxiglucose F18 , Neoplasias Ovarianas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígeno Ca-125/sangue , Feminino , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/cirurgia , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida
9.
Gynecol Oncol ; 108(2): 265-70, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18055006

RESUMO

OBJECTIVE: To prospectively identify combined PET/CT predictors of incomplete/suboptimal primary cytoreduction in advanced ovarian cancer. METHODS: From September 2004 to March 2007, 179 patients with a Risk of Malignancy Index (RMI) >150 based on serum CA-125, ultrasound examinations and menopausal state, underwent PET/CT within 2 weeks prior to standard surgery/debulking of a pelvic tumor. Ten PET/CT features were identified and evaluated as predictors of cytoreduction in 54 patients with advanced ovarian cancer. RESULTS: Complete cytoreduction (no macroscopic residual disease) was achieved in 35% and optimal cytoreduction (<1 cm residual disease) was achieved in 56%. Using univariate analysis, predictors of incomplete cytoreduction were large bowel mesentery implants (LBMI) (P<0.003), pleural effusion (P<0.009), ascites (P<0.009) and peritoneal carcinosis (P<0.01). LBMI (P<0.03) and ascites (P<0.05) were also predictors of suboptimal cytoreduction. Using multivariate analysis, LBMI was the only independent predictor of incomplete cytoreduction (P=0.004) and no predictor of suboptimal cytoreduction was found. CONCLUSION: PET/CT predictors of cytoreduction were found. But they should not be used to withhold patients form primary cytoreductive surgery. We suggest PET/CT as a supplementary image modality prior to surgery in primary OC patients whenever accurate and comprehensive preoperative evaluation of primary tumor and metastases is desired.


Assuntos
Adenocarcinoma/diagnóstico , Adenocarcinoma/cirurgia , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/cirurgia , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/patologia , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
10.
Acta Radiol ; 48(4): 369-78, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17453514

RESUMO

BACKGROUND: The choice of imaging before liver surgery is debated regarding the use of magnetic resonance (MR) imaging, computed tomography (CT), and positron emission tomography (PET). No studies have compared contrast-enhanced PET/CT with superparamagnetic iron oxide (SPIO)-enhanced MR imaging. PURPOSE: To compare PET/CT with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, PET, and CT in the detection of liver metastases (LM) and extrahepatic tumor from colorectal cancer (CRC). MATERIAL AND METHODS: Thirty-five patients with suspected LM underwent PET/CT with a contrast-enhanced CT protocol and SPIO-enhanced MR imaging. Readers independently analyzed images from MR imaging, PET/CT, and the CT part and PET part of the PET/CT study. Imaging findings were compared with surgical and histological findings. RESULTS: Lesion-by-lesion sensitivity and accuracy for liver lesions was 54% and 77% for PET alone, 66% and 83% for PET/CT, 82% and 82% for SPIO-enhanced MR imaging, and 89% and 77% for CT alone, respectively. CT and SPIO-enhanced MR imaging were less specific but significantly more sensitive than PET (P<0.0001). For extrahepatic tumor, sensitivity and specificity was 83% and 96% for PET/CT and 58% and 87% for CT, respectively. CONCLUSION: CT and SPIO-enhanced MR imaging are more sensitive but less specific than PET in the detection of LM. PET/CT can detect more patients with extrahepatic tumor than CT alone.


Assuntos
Neoplasias do Colo/patologia , Meios de Contraste , Aumento da Imagem/métodos , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Retais/patologia , Tomografia Computadorizada por Raios X/métodos , Neoplasias Abdominais/secundário , Adulto , Idoso , Dextranos , Feminino , Óxido Ferroso-Férrico , Fluordesoxiglucose F18 , Humanos , Ferro , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/secundário , Metástase Linfática/diagnóstico , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Óxidos , Neoplasias Peritoneais/secundário , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
11.
Ann Oncol ; 18(2): 338-45, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17060487

RESUMO

BACKGROUND: Small-cell lung cancer (SCLC) accounts for 15%-20% of all lung cancer cases. Accurate and fast staging is mandatory when choosing treatment, but current staging procedures are time consuming and lack sensitivity. PATIENTS AND METHODS: A prospective study was designed to examine the role of combined positron emission tomography/computed tomography (PET/CT) compared with standard staging (CT, bone scintigraphy and immunocytochemical assessment of bone marrow biopsy) of patients with SCLC. Thirty-four consecutive patients were included. Twenty-nine patients received initial PET/CT. RESULTS: PET/CT caused change of stage in 5/29 (17%). Excluding patients with unconfirmed findings or pleural effusion, the sensitivity for accurate staging of patients with extensive disease was the following: for standard staging 79%, PET 93% and PET/CT 93%. Specificity was 100%, 83% and 100%, respectively. CONCLUSION: The results from this first study on PET/CT in SCLC indicates that PET/CT can simplify and perhaps even improve the accuracy of the current staging procedure in SCLC. A larger clinical trial, preferably with consequent histological confirmation in case of discordance, however, is warranted.


Assuntos
Medula Óssea/patologia , Neoplasias Ósseas/diagnóstico por imagem , Carcinoma de Células Pequenas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Idoso , Neoplasias Ósseas/secundário , Carcinoma de Células Pequenas/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
12.
Eur J Nucl Med Mol Imaging ; 32(10): 1167-75, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15909196

RESUMO

PURPOSE: If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can be used for PET attenuation without reducing the clinical value of the PET scan. METHODS: A uniform phantom study was used to document that the PET acquisition itself is not significantly influenced by the presence of IV contrast medium. Then, 19 patients referred to PET/CT with IV contrast underwent CT scans without, and then with contrast agent, followed by an 18F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global comparison of standard uptake value (SUV) was performed, and SUVs in tumour, in non-tumour tissue and in the subclavian vein were calculated. Clinical evaluation of the number and location of lesions on all PET/CT scans was performed twice, blinded and in a different random order, by two independent nuclear medicine specialists. RESULTS: In all patients, the measured global SUV of PET images based on CT with IV contrast agent was higher than the global activity using non-contrast correction. The overall increase in the mean SUV (for two different conversion tables tested) was 4.5+/-2.3% and 1.6+/-0.5%, respectively. In 11/19 patients, focal uptake was identified corresponding to malignant tumours. Eight out of 11 tumours showed an increased SUVmax (2.9+/-3.1%) on the PET images reconstructed using IV contrast. The clinical evaluation performed by the two specialists comparing contrast and non-contrast CT attenuated PET images showed weighted kappa values of 0.92 (doctor A) and 0.82 (doctor B). No contrast-introduced artefacts were found. CONCLUSION: This study demonstrates that CT scans with IV contrast agent can be used for attenuation correction of the PET data in combined modality PET/CT scanning, without changing the clinical diagnostic interpretation.


Assuntos
Artefatos , Aumento da Imagem/métodos , Ácido Iotalâmico/análogos & derivados , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Fluordesoxiglucose F18 , Humanos , Injeções Intravenosas , Ácido Iotalâmico/administração & dosagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Técnica de Subtração , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...