Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
2.
J Nucl Med ; 63(12): 1871-1879, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35589407

RESUMO

Tissue factor (TF) expression in cancers correlates with poor prognosis. Recently, the first TF-targeted therapy was approved by the U.S. Food and Drug Administration for cervical cancer. To unfold the potential of TF-targeted therapies, correct stratification and selection of patients eligible for treatments may become important for optimization of patient outcomes. TF-targeted PET imaging based on 18F-radiolabeled active-site inhibited versions of the TF natural ligand coagulation factor VII (18F-ASIS) has in preclinical models convincingly demonstrated its use for noninvasive quantitative measurements of TF expression in tumor tissue. 18F-ASIS PET imaging thus has the potential to act as a diagnostic companion for TF-targeted therapies in the clinical setting. Methods: In this first-in-humans trial, we included 10 cancer patients (4 pancreatic, 3 breast, 2 lung, and 1 cervical cancer) for 18F-ASIS PET imaging. The mean and SD of administered 18F-ASIS activity was 157 ± 35 MBq (range, 93-198 MBq). PET/CT was performed after 1, 2, and 4 h. The primary objectives were to establish the safety, biodistribution, pharmacokinetics, and dosimetry of 18F-ASIS. Secondary objectives included quantitative measurements of SUVs in tumor tissue with PET and evaluation of the correlation (Pearson correlation) between tumor SUVmax and ex vivo TF expression in tumor tissue. Results: Administration of 18F-ASIS was safe, and no adverse events were observed. No clinically significant changes in vital signs, electrocardiograms, or blood parameters were observed after injection of 18F-ASIS. Mean 18F-ASIS plasma half-life was 3.2 ± 0.6 h, and the radiotracer was predominantly excreted in the urine. For injection activity of 200 MBq of 18F-ASIS, effective whole-body dose was 4 mSv and no prohibitive organ-specific absorbed doses were found. Heterogeneous radiotracer uptake was observed across patients and within tumors. We found a trend of a positive correlation between tumor SUVmax and ex vivo TF expression (r = 0.84, P = 0.08, n = 5). Conclusion: 18F-ASIS can be safely administered to cancer patients for PET imaging of TF expression in tumors. The trial marks the first test of a TF-targeted PET radiotracer in humans (first-in-class). The findings represent important first steps toward clinical implementation of 18F-ASIS PET imaging of TF expression.


Assuntos
Segunda Neoplasia Primária , Neoplasias do Colo do Útero , Feminino , Humanos , Fator VII/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Radiometria , Tromboplastina/metabolismo , Distribuição Tecidual
3.
EJNMMI Phys ; 9(1): 20, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35294629

RESUMO

BACKGROUND: Quantitative whole-body PET/MRI relies on accurate patient-specific MRI-based attenuation correction (AC) of PET, which is a non-trivial challenge, especially for the anatomically complex head and neck region. We used a deep learning model developed for dose planning in radiation oncology to derive MRI-based attenuation maps of head and neck cancer patients and evaluated its performance on PET AC. METHODS: Eleven head and neck cancer patients, referred for radiotherapy, underwent CT followed by PET/MRI with acquisition of Dixon MRI. Both scans were performed in radiotherapy position. PET AC was performed with three different patient-specific attenuation maps derived from: (1) Dixon MRI using a deep learning network (PETDeep). (2) Dixon MRI using the vendor-provided atlas-based method (PETAtlas). (3) CT, serving as reference (PETCT). We analyzed the effect of the MRI-based AC methods on PET quantification by assessing the average voxelwise error within the entire body, and the error as a function of distance to bone/air. The error in mean uptake within anatomical regions of interest and the tumor was also assessed. RESULTS: The average (± standard deviation) PET voxel error was 0.0 ± 11.4% for PETDeep and -1.3 ± 21.8% for PETAtlas. The error in mean PET uptake in bone/air was much lower for PETDeep (-4%/12%) than for PETAtlas (-15%/84%) and PETDeep also demonstrated a more rapidly decreasing error with distance to bone/air affecting only the immediate surroundings (less than 1 cm). The regions with the largest error in mean uptake were those containing bone (mandible) and air (larynx) for both methods, and the error in tumor mean uptake was -0.6 ± 2.0% for PETDeep and -3.5 ± 4.6% for PETAtlas. CONCLUSION: The deep learning network for deriving MRI-based attenuation maps of head and neck cancer patients demonstrated accurate AC and exceeded the performance of the vendor-provided atlas-based method both overall, on a lesion-level, and in vicinity of challenging regions such as bone and air.

4.
Adv Radiat Oncol ; 6(6): 100762, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34585026

RESUMO

PURPOSE: Radiotherapy planning based only on positron emission tomography/magnetic resonance imaging (PET/MRI) lacks computed tomography (CT) information required for dose calculations. In this study, a previously developed deep learning model for creating synthetic CT (sCT) from MRI in patients with head and neck cancer was evaluated in 2 scenarios: (1) using an independent external dataset, and (2) using a local dataset after an update of the model related to scanner software-induced changes to the input MRI. METHODS AND MATERIALS: Six patients from an external site and 17 patients from a local cohort were analyzed separately. Each patient underwent a CT and a PET/MRI with a Dixon MRI sequence over either one (external) or 2 (local) bed positions. For the external cohort, a previously developed deep learning model for deriving sCT from Dixon MRI was directly applied. For the local cohort, we adapted the model for an upgraded MRI acquisition using transfer learning and evaluated it in a leave-one-out process. The sCT mean absolute error for each patient was assessed. Radiotherapy dose plans based on sCT and CT were compared by assessing relevant absorbed dose differences in target volumes and organs at risk. RESULTS: The MAEs were 78 ± 13 HU and 76 ± 12 HU for the external and local cohort, respectively. For the external cohort, absorbed dose differences in target volumes were within ± 2.3% and within ± 1% in 95% of the cases. Differences in organs at risk were <2%. Similar results were obtained for the local cohort. CONCLUSIONS: We have demonstrated a robust performance of a deep learning model for deriving sCT from MRI when applied to an independent external dataset. We updated the model to accommodate a larger axial field of view and software-induced changes to the input MRI. In both scenarios dose calculations based on sCT were similar to those of CT suggesting a robust and reliable method.

5.
J Nucl Med ; 62(1): 73-80, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32444370

RESUMO

64Cu-DOTATATE PET/CT imaging 1 h after injection is excellent for lesion detection in patients with neuroendocrine neoplasms (NENs). We hypothesized that the imaging time window can be extended up to 3 h after injection without significant differences in the number of lesions detected. Methods: From a prospective study, we compared, on a head-to-head basis, sets of 64Cu-DOTATATE PET/CT images from 35 patients with NENs scanned 1 and 3 h after injection of 200 MBq of 64Cu-DOTATATE. The number of lesions on both PET scans was counted and grouped according to organs or regions and compared with negative binomial regression. Discordant lesions (visible on only the 1-h images or only the 3-h 64Cu-DOTATATE PET images) were considered true if found on simultaneous CT or later MR, CT, or somatostatin receptor imaging. We measured lesion SUVmax, reference normal-organ or -tissue SUVmean, and tumor-to-normal-tissue ratios calculated from SUVmax and SUVmeanResults: We found 822 concordant lesions (visible on both 1-h and 3-h 64Cu-DOTATATE PET) and 5 discordant lesions, of which 4 were considered true. One discordant case in 1 patient involved a discordant organ system (lymph node) detected on 3-h but not 1-h 64Cu-DOTATATE PET that did not alter the patient's disease stage (stage IV) because the patient had 11 additional concordant liver lesions. We found no significant differences between the number of lesions detected on 1-h and 3-h 64Cu-DOTATATE PET. Throughout the 1- to 3-h imaging window, the mean tumor-to-normal-tissue ratio remained high in all key organs: liver (1 h: 12.6 [95% confidence interval (CI), 10.2-14.9]; 3 h: 11.0 [95%CI, 8.7-13.4]), intestines (1 h: 24.2 [95%CI, 14.9-33.4]; 3 h: 28.2 [95%CI, 16.5-40.0]), pancreas (1 h: 42.4 [95%CI, 12.3-72.5]; 3 h: 41.1 [95%CI, 8.7-73.4]), and bone (1 h: 103.0 [95%CI, 38.6-167.4]; 3 h: 124.2 [95%CI, 57.1-191.2]). Conclusion: The imaging time window of 64Cu-DOTATATE PET/CT for patients with NENs can be expanded from 1 h to 1-3 h without significant differences in the number of lesions detected.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida/análogos & derivados , Compostos Organometálicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
6.
Int J Radiat Oncol Biol Phys ; 108(5): 1329-1338, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32682955

RESUMO

PURPOSE: Multiparametric positron emission tomography (PET)/magnetic resonance imaging (MRI) as a one-stop shop for radiation therapy (RT) planning has great potential but is technically challenging. We studied the feasibility of performing multiparametric PET/MRI of patients with head and neck cancer (HNC) in RT treatment position. As a step toward planning RT based solely on PET/MRI, a deep learning approach was employed to generate synthetic computed tomography (sCT) from MRI. This was subsequently evaluated for dose calculation and PET attenuation correction (AC). METHODS AND MATERIALS: Eleven patients, including 3 pilot patients referred for RT of HNC, underwent PET/MRI in treatment position after a routine fluorodeoxyglucose-PET/CT planning scan. The PET/MRI scan protocol included multiparametric imaging. A convolutional neural network was trained in a leave-one-out process to predict sCT from the Dixon MRI. The clinical CT-based dose plans were recalculated on sCT, and the plans were compared in terms of relative differences in mean, maximum, near-maximum, and near-minimum absorbed doses for different volumes of interest. Comparisons between PET with sCT-based AC and PET with CT-based AC were assessed based on the relative differences in mean and maximum standardized uptake values (SUVmean and SUVmax) from the PET-positive volumes. RESULTS: All 11 patients underwent PET/MRI in RT treatment position. Apart from the 3 pilots, full multiparametric imaging was completed in 45 minutes for 7 out of 8 patients. One patient terminated the examination after 30 minutes. With the exception of 1 patient with an inserted tracheostomy tube, all dosimetric parameters of the sCT-based dose plans were within ±1% of the CT-based dose plans. For PET, the mean difference was 0.4 ± 1.2% for SUVmean and -0.5 ± 1.0% for SUVmax. CONCLUSIONS: Performing multiparametric PET/MRI of patients with HNC in RT treatment position was clinically feasible. The sCT generation resulted in AC of PET and dose calculations sufficiently accurate for clinical use. These results are an important step toward using multiparametric PET/MRI as a one-stop shop for personalized RT planning.


Assuntos
Aprendizado Profundo , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Estudos de Viabilidade , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Redes Neurais de Computação , Posicionamento do Paciente , Estudos Prospectivos , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
7.
Clin Physiol Funct Imaging ; 38(2): 278-284, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28168798

RESUMO

BACKGROUND: 18 F-FDG PET/CT (FDG PET/CT) used in radiotherapy planning for extra-cerebral malignancy may reveal metastases to distant sites that may affect the choice of therapy. AIM: To investigate the role of FDG PET/CT on treatment strategy changes induced by the use of PET/CT as part of the radiotherapy planning. 'A major change of treatment strategy' was defined as either including more lesions in the gross tumour volume (GTV) distant from the primary tumour or a change in treatment modalities. METHODS: The study includes 581 consecutive patients who underwent an FDG PET/CT scan for radiotherapy planning in our institution in the year 2008. All PET/CT scans were performed with the patient in treatment position with the use of immobilization devices according to the intended radiotherapy treatment. All scans were evaluated by a nuclear medicine physician together with a radiologist to delineate PET-positive GTV (GTV-PET). RESULTS: For 63 of the patients (11%), the PET/CT simulation scans resulted in a major change in treatment strategy because of the additional diagnostic information. Changes were most frequently observed in patients with lung cancer (20%) or upper gastrointestinal cancer (12%). In 65% of the patients for whom the PET/CT simulation scan revealed unexpected dissemination, radiotherapy was given - changed (n = 38) or unchanged (n = 13) according to the findings on the FDG PET/CT. CONCLUSION: Unexpected dissemination on the FDG PET/CT scanning performed for radiotherapy planning caused a change in treatment strategy in 11% of 581 patients.


Assuntos
Tomada de Decisão Clínica , Fluordesoxiglucose F18/administração & dosagem , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/administração & dosagem , Planejamento da Radioterapia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias/patologia , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Retrospectivos , Carga Tumoral , Adulto Jovem
8.
Radiother Oncol ; 126(3): 479-486, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29050958

RESUMO

BACKGROUND AND PURPOSE: Two techniques for metal artefact reduction for computed tomography were studied in order to identify their impact on tumour delineation in radiotherapy. MATERIALS AND METHODS: Using specially designed phantoms containing metal implants (dental, spine and hip) as well as patient images, we investigated the impact of two methods for metal artefact reduction on (A) the size and severity of metal artefacts and the accuracy of Hounsfield Unit (HU) representation, (B) the visual impact of metal artefacts on image quality and (C) delineation accuracy. A metal artefact reduction algorithm (MAR) and two types of dual energy virtual monochromatic (DECT VM) reconstructions were used separately and in combination to identify the optimal technique for each implant site. RESULTS: The artefact area and severity was reduced (by 48-76% and 58-79%, MAR and DECT VM respectively) and accurate Hounsfield-value representation was increased by 22-82%. For each energy, the observers preferred MAR over non-MAR reconstructions (p < 0.01 for dental and hip cases, p < 0.05 for the spine case). In addition, DECT VM was preferred for spine implants (p < 0.01). In all cases, techniques that improved target delineation significantly (p < 0.05) were identified. CONCLUSIONS: DECT VM and MAR techniques improve delineation accuracy and the optimal of reconstruction technique depends on the type of metal implant.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Coração/diagnóstico por imagem , Coração/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Artefatos , Estudos de Coortes , Feminino , Coração/anatomia & histologia , Humanos , Metais , Imagens de Fantasmas , Estudos Prospectivos , Próteses e Implantes , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
9.
Int J Cardiovasc Imaging ; 33(5): 751-760, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28050751

RESUMO

The extra-cardiac work-up in infective endocarditis (IE) comprises a search for primary and secondary infective foci. Whether 18FDG-PET/CT or WBC-SPECT/CT is superior in detection of clinically relevant extra-cardiac manifestations in IE is unexplored. The objectives of this study were to identify the numbers of positive findings detected by each imaging modality, to evaluate the clinical relevance of these findings and to define the reproducibility for extra-cardiac foci in patients with definite IE. Each modality was evaluated for numbers and location of positive extra-cardiac foci in patients with definite IE. A team of 2 × 2 cardiologists evaluated each finding to determine clinical relevance. Clinical utility was determined by 4 criteria converted into an ordinal scale. Using the manifestation with highest clinical utility rating in each patient, the clinical impact of the two imaging modalities was expressed in a clinical utility score. To evaluate reproducibility for each modality, an imaging core laboratory reviewed all findings. In 55 IE patients, 91 pathological foci were found by FDG-PET/CT and 37 foci were identified by WBC-SPECT/CT (p < 0.001). The clinical utility of FDG-PET/CT was significantly higher than that of WBC-SPECT/CT when comparing clinical utility score (2.06 vs. 1.17; p = 0.01). In assessment of extra-cardiac diagnostics in IE, inter-observer reproducibility was substantial for WBC-SPECT/CT (k 0.69, 95% CI 0.49-0.89) and substantial to excellent for FDG-PET/CT (k 0.79, 95% CI 0.61-0.98). FDG-PET/CT has a significantly higher clinical utility score than WBC SPECT/CT and is potentially superior to WBC-SPECT/CT in detection of extra-cardiac pathology in patients with IE.


Assuntos
Endocardite/diagnóstico por imagem , Fluordesoxiglucose F18/administração & dosagem , Leucócitos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/administração & dosagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tecnécio Tc 99m Exametazima/administração & dosagem , Idoso , Endocardite/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
10.
J Nucl Med ; 58(3): 451-457, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27660147

RESUMO

Somatostatin receptor imaging is a valuable tool in the diagnosis, follow-up, and treatment planning of neuroendocrine tumor (NET). PET-based tracers using 68Ga as the radioisotope have in most centers replaced SPECT-based tracers as the gold standard. 64Cu-DOTATATE is a new PET tracer that has been shown to be far superior to the SPECT tracer 111In-diethylenetriaminepentaacetic acid-octreotide. Because of the advantages of 64Cu over 68Ga, we hypothesized that the tracer has a higher sensitivity than 68Ga-based tracers. To test this hypothesis, we compared on a head-to-head basis the diagnostic performance of 64Cu-DOTATATE with that of 68Ga-DOTATOC in NET patients. Methods: Fifty-nine NET patients were scanned with both 64Cu-DOTATATE and 68Ga-DOTATOC PET/CT and compared on a head-to-head basis. Discordant lesions were verified during at least 30 mo of follow-up. Results: A total of 701 lesions were concordantly detected on both 64Cu-DOTATATE and 68Ga-DOTATOC PET/CT scans, whereas an additional 68 lesions were found by only one of the scans. 64Cu-DOTATATE showed 42 lesions not found on 68Ga-DOTATOC, of which 33 were found to be true-positive on follow-up. 68Ga-DOTATOC showed 26 lesions not found on 64Cu-DOTATATE, of which 7 were found to be true-positive on follow-up. False-positives were mainly lymph node lesions. Accordingly, 83% of the additional true lesions found on only one of the scans were found by 64Cu-DOTATATE. On a patient-basis, additional true lesions were found by 64Cu-DOTATATE and 68Ga-DOTATOC in 13 and 3 patients, respectively. All patients with additional lesions also had concordant lesions found by both scans. Conclusion:64Cu-DOTATATE has advantages over 68Ga-DOTATOC in the detection of lesions in NET patients. Although patient-based sensitivity was the same for 64Cu-DOTATATE and 68Ga-DOTATOC in this cohort, significantly more lesions were detected by 64Cu-DOTATATE. Furthermore, the shelf life of more than 24 h and the scanning window of at least 3 h make 64Cu-DOTATATE favorable and easy to use in the clinical setting.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida/análogos & derivados , Compostos Organometálicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Int J Radiat Oncol Biol Phys ; 92(1): 169-74, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25754634

RESUMO

PURPOSE: Hodgkin lymphoma (HL) survivors have an increased risk of cardiovascular disease (CD), lung cancer, and breast cancer. We investigated the risk for the development of CD and secondary lung, breast, and thyroid cancer after radiation therapy (RT) delivered with deep inspiration breath-hold (DIBH) compared with free-breathing (FB) using 3-dimensional conformal RT (3DCRT) and intensity modulated RT (IMRT). The aim of this study was to determine which treatment modality best reduced the combined risk of life-threatening late effects in patients with mediastinal HL. METHODS AND MATERIALS: Twenty-two patients with early-stage mediastinal HL were eligible for the study. Treatment plans were calculated with both 3DCRT and IMRT on both DIBH and FB planning computed tomographic scans. We reported the estimated dose to the heart, lung, female breasts, and thyroid and calculated the estimated life years lost attributable to CD and to lung, breast, and thyroid cancer. RESULTS: DIBH lowered the estimated dose to heart and lung regardless of delivery technique (P<.001). There was no significant difference between IMRT-FB and 3DCRT-DIBH in mean heart dose, heart V20Gy, and lung V20Gy. The mean breast dose was increased with IMRT regardless of breathing technique. Life years lost was lowest with DIBH and highest with FB. CONCLUSIONS: In this cohort, 3DCRT-DIBH resulted in lower estimated doses and lower lifetime excess risks than did IMRT-FB. Combining IMRT and DIBH could be beneficial for a subgroup of patients.


Assuntos
Suspensão da Respiração , Doença de Hodgkin/radioterapia , Neoplasias do Mediastino/radioterapia , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária/etiologia , Órgãos em Risco/efeitos da radiação , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Respiração , Mama/efeitos da radiação , Neoplasias da Mama/etiologia , Doenças Cardiovasculares/etiologia , Feminino , Coração/diagnóstico por imagem , Coração/efeitos da radiação , Doença de Hodgkin/mortalidade , Humanos , Inalação , Tábuas de Vida , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Neoplasias Pulmonares/etiologia , Masculino , Neoplasias do Mediastino/mortalidade , Órgãos em Risco/diagnóstico por imagem , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/efeitos da radiação , Neoplasias da Glândula Tireoide/etiologia
13.
Acta Oncol ; 54(1): 60-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25025999

RESUMO

BACKGROUND: Long-term Hodgkin lymphoma (HL) survivors have an increased risk of late cardiac morbidity and secondary lung cancer after chemotherapy and mediastinal radiotherapy. In this prospective study we investigate whether radiotherapy with deep inspiration breath-hold (DIBH) can reduce radiation doses to the lungs, heart, and cardiac structures without compromising the target dose. PATIENTS AND METHODS: Twenty-two patients (14 female, 8 male), median age 30 years (18-65 years), with supra-diaphragmatic HL were enrolled and had a thoracic PET/CT with DIBH in addition to staging FDG-PET/CT in free breathing (FB) and a planning CT in both FB and DIBH. For each patient an involved-node radiotherapy plan was done for both DIBH and FB, and the doses to the lungs, heart, and female breasts were recorded prospectively. Mean doses to the heart valves and coronary arteries were recorded retrospectively. Patients were treated with the technique yielding the lowest doses to normal structures. RESULTS: Nineteen patients were treated with DIBH and three with FB. DIBH reduced the mean estimated lung dose by 2.0 Gy (median: 8.5 Gy vs. 7.2 Gy) (p < 0.01) and the mean heart dose by 1.4 Gy (6.0 Gy vs. 3.9 Gy) (p < 0.01) compared to FB. The lung and heart V20Gy were reduced with a median of 5.3% and 6.3%. Mean doses to the female breasts were equal with FB and DIBH. CONCLUSION: DIBH can significantly decrease the estimated mean doses to the heart and lungs without lowering the dose to the target in radiotherapy for patients with mediastinal HL.


Assuntos
Suspensão da Respiração , Coração/efeitos da radiação , Doença de Hodgkin/radioterapia , Inalação , Pulmão/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Lesões por Radiação/prevenção & controle , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Mama/efeitos da radiação , Feminino , Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Doses de Radiação , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Adulto Jovem
14.
Radiother Oncol ; 111(3): 360-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24993331

RESUMO

BACKGROUND AND PURPOSE: To analyze the recurrence pattern in relation to target volumes and (18)F-fluorodeoxyglucose (FDG) uptake on positron emission tomography in head and neck squamous cell carcinoma (HNSCC) patients treated with definitive chemoradiation. MATERIAL AND METHODS: 520 patients received radiotherapy for HNSCC from 2005 to 2009. Among 100 patients achieving complete clinical response and a later recurrence, 39 patients with 48 loco-regional failures had a recurrence CT scan before any salvage therapy. The estimated point of origin of each recurrence was transferred to the planning CT by deformable image co-registration. The recurrence position was then related to the delineated target volumes and iso-SUV-contours relative to the maximum standard uptake value (SUV). We defined the recurrence density as the total number of recurrences in a sub-volume divided by the sum of that volume for all patients. RESULTS: 54% (95% CI 37-69%) of recurrences originated inside the FDG-positive volume and 96% (95% CI 86-99%) in the high dose region. Recurrence density was significantly higher in the central target volumes (P<0.0001) and increased with increasing FDG avidity (P=0.036). CONCLUSIONS: The detailed pattern-of-failure data analysis suggests that most recurrences occur in the FDG PET positive areas or the solid tumor.


Assuntos
Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/radioterapia , Fluordesoxiglucose F18/farmacocinética , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/radioterapia , Compostos Radiofarmacêuticos/farmacocinética , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Imagem Multimodal/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Tomografia Computadorizada por Raios X/métodos
15.
Med Phys ; 40(8): 081717, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927314

RESUMO

PURPOSE: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed. METHODS: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose-response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy. RESULTS: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%-91%) as compared to the observed TCP of 70%. CONCLUSIONS: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity.


Assuntos
Modelos Estatísticos , Neoplasias/radioterapia , Doses de Radiação , Humanos , Probabilidade , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Falha de Tratamento
16.
Oncologist ; 17(9): 1146-54, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22711751

RESUMO

BACKGROUND: The aim of the present study was to evaluate prospectively the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) and conventional CT regarding the ability to detect the primary tumor site in patients with extracervical metastases from carcinoma of unknown primary (CUP) site. PATIENTS AND METHODS: From January 2006 to December 2010, 136 newly diagnosed CUP patients with extracervical metastases underwent (18)F-FDG PET/CT. A standard of reference (SR) was established by a multidisciplinary team to ensure that the same set of criteria were used for classification of patients, that is, either as CUP patients or patients with a suggested primary tumor site. The independently obtained suggestions of primary tumor sites using PET/CT and CT were correlated with the SR to reach a consensus regarding true-positive (TP), true-negative, false-negative, and false-positive results. RESULTS: SR identified a primary tumor site in 66 CUP patients (48.9%). PET/CT identified 38 TP primary tumor sites and CT identified 43 TP primary tumor sites. No statistically significant differences were observed between (18)F-FDG PET/CT and CT alone in regard to sensitivity, specificity, and accuracy. CONCLUSION: In the general CUP population with multiple extracervical metastases (18)F-FDG PET/CT does not represent a clear diagnostic advantage over CT alone regarding the ability to detect the primary tumor site.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Primárias Desconhecidas/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Colo do Útero/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Metástase Linfática/diagnóstico , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Neoplasias Primárias Desconhecidas/diagnóstico por imagem , Neoplasias Primárias Desconhecidas/patologia , Estudos Prospectivos , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia
17.
Acta Oncol ; 50(3): 415-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20698810

RESUMO

INTRODUCTION: In patients with advanced ovarian cancer undergoing preoperative PET/CT, we investigated the prognostic value of SUV in the primary tumor and we evaluated the value of SUV for predicting incomplete primary cytoreduction (macroscopic residual tumor). MATERIAL AND METHODS: From September 2004 to August 2007, 201 consecutive patients with a pelvic tumor and a Risk of Malignancy Index (RMI) > 150 based on serum CA-125, ultrasound examinations and menopausal state, underwent PET/CT within two weeks prior to standard surgery/debulking of a pelvic tumor. At two-year follow-up (August 15, 2009) the association between SUV and overall survival/cytoreductive result were analyzed in 60 ovarian cancer patients (58 stage III and two stage IV). RESULTS: At inclusion median age was 62 years (range 35-85 years); 97% (58/60) had a performance status ≤2; 42% (25/60) underwent complete debulking (no macroscopic residual tumor); median SUV(max) was 13.5 (range 2.5-39.0). Median follow-up was 30.2 months. At follow-up 57% (34/60) were alive and 43% (26/60) had died from ovarian cancer. SUV(max) in patients alive was not statistically different from SUV(max) in dead patients (p=0.69), and SUV(max) was not correlated with the amount of residual tumor after surgery (p=0.19). Using univariate Cox regression analysis, residual tumor was a significant prognostic variable (p=0.001); SUV(max) was not a statistically significant prognostic variable (p=0.86). DISCUSSION: FDG uptake (SUV(max)) in the primary tumor of patients with advanced ovarian cancer was not a prognostic variable and the FDG uptake did not predict complete cytoreduction after primary surgery. Future prospective clinical trials will need to clarify if other PET tracers can serve as prognostic variables in ovarian cancer.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/cirurgia , Fluordesoxiglucose F18/farmacocinética , Neoplasia Residual/diagnóstico por imagem , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/cirurgia , Adenocarcinoma/metabolismo , Adenocarcinoma/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Progressão da Doença , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasia Residual/metabolismo , Neoplasia Residual/mortalidade , Neoplasias Ovarianas/metabolismo , Neoplasias Ovarianas/mortalidade , Ovariectomia/métodos , Ovariectomia/normas , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/normas , Prognóstico , Análise de Sobrevida
18.
Acta Oncol ; 49(7): 984-90, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20831486

RESUMO

BACKGROUND: Focal methods to determine the source of recurrence are presented, tested for reproducibility and compared to volumetric approaches with respect to the number of recurrences ascribed to the FDG-PET positive and high dose volumes. MATERIAL AND METHODS: Six patients treated for hypopharyngeal squamous cell carcinoma were extracted from archives. Inclusion criteria were: FDG-PET/CT for primary radiotherapy planning and clinical complete remission followed by loco-regional relapse. CT scan at the time of recurrence was also required. The recurrence volume was delineated in the follow-up scans by a radiologist. Putative points of origin (PO) of the recurrence were determined by two strategies 1) defined by an oncologist or 2) as the center-of-volume (COV) of the recurrence. The most likely recurrence point of origin on the treatment planning scan was also determined. All expert based points of origin were repeated to estimate reproducibility. The recurrence volume and PO were propagated to the treatment planning scan using a rigid transformation. Relations of the PO to target volumes, radiation doses and therapy-points-of-origin were quantified. For the volumetric methods, the overlap of the recurrence volume and target volumes was used to determine the source of the recurrence. RESULTS: All recurrences were located in-field, but the volumetric approaches tended to designate fewer recurrences in the PET positive volume (25% for the 95% threshold, 95% confidence interval (CI):3-65%) than the observer-based methods (50% for the COV and both expert evaluations on the recurrence scan, 95% CI: 16-84%). The reproducibility of the expert POs is better on the recurrence scan than on the therapy scan. CONCLUSION: Volumetric approaches favor large target volumes as the source of the recurrence, thus underestimating the number of recurrences originating in the PET positive volume. Expert based and COV approaches on the recurrence scan are the most reproducible methods to determine the PO.


Assuntos
Carcinoma de Células Escamosas , Fluordesoxiglucose F18 , Neoplasias Hipofaríngeas , Recidiva Local de Neoplasia , Tomografia por Emissão de Pósitrons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Feminino , Humanos , Neoplasias Hipofaríngeas/diagnóstico por imagem , Neoplasias Hipofaríngeas/patologia , Neoplasias Hipofaríngeas/radioterapia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/radioterapia , Radioterapia Conformacional/métodos , Carga Tumoral
19.
Int J Gynecol Cancer ; 19(4): 600-4, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19509556

RESUMO

The objective of this prospective study was to compare the sensitivities and the specificities of combined 2-(F) fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT), abdominal/transvaginal ultrasound (US), and CT for diagnosing recurrent ovarian cancer (OC) and to evaluate the influence of PET/CT on referral of patients with solitary recurrence to secondary cytoreductive surgery. From April 2005 to November 2007, 60 patients were consecutively included to PET/CT 68 times. The inclusion criteria were remission of 3 months or longer and recurrent OC suspected from physical examination, US, or increasing cancer antigen 125 (CA125) level (>50 U/mL or >15% above baseline level). Recurrent OC was diagnosed 58 times in 52 patients. The sensitivities of US, CT, and PET/CT for diagnosing recurrence were 66% (P = 0.003), 81% (P = 0.0001), and 97% (P < 0.0001), respectively. The specificity of US, CT, and PET/CT for diagnosing recurrence was 90%. Positron emission tomography/CT diagnosed recurrence in 19 (66%) of 29 patients without recurrence according to US and in 10 (50%) of 20 patients without recurrence after CT. Multiple recurrent tumors were found using PET/CT in 27 (69%) of 39 patients with solitary tumors on US and in 8 (42%) of 19 patients with solitary tumors on CT. We conclude that the diagnostic value of PET/CT for detecting recurrent OC was higher than those of US and CT and that PET/CT more accurately identified patients with solitary recurrence. However, prospective clinical trials are needed to specify the characteristics of patients most likely to undergo complete secondary surgery and to further clarify the role of PET/CT in selecting patients for secondary surgery.


Assuntos
Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/cirurgia , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/cirurgia , Compostos Radiofarmacêuticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto Jovem
20.
Dis Colon Rectum ; 51(1): 21-5, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17975715

RESUMO

PURPOSE: The objective of this study was to investigate the possibility of using positron emission tomography/computer tomography to predict the histopathologic response in locally advanced rectal cancer treated with preoperative chemoradiation. METHODS: The study included 30 patients with locally advanced rectal adenocarcinoma treated with a combination of radiotherapy and concurrent Uftoral (uracil, tegafur) and leucovorine. All patients were evaluated by positron emission tomography/computer tomography scan seven weeks after end of chemoradiation, and the results were compared to histopathologic tumor regression as the "standard." The pathologic response was quantified by tumor regression grade. RESULTS: Positron emission tomography/computer tomography correctly identified six of eight patients (specificity 75 percent) with complete pathologic response. However, the sensitivity of positron emission tomography/computer tomography was only 45 percent and the accuracy 53 percent. The positive and negative predictive values were 83 and 33 percent, respectively. CONCLUSIONS: We conclude that positron emission tomography/computer tomography performed seven weeks after the end of chemoradiation is not able to predict the histopathologic response in locally advanced rectal cancer. There is an obvious need for other complementary methods especially with respect to the low sensitivity of positron emission tomography/computer tomography.


Assuntos
Neoplasias Retais/patologia , Neoplasias Retais/terapia , Tomografia Computadorizada de Emissão , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimioterapia Adjuvante , Terapia Combinada , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/prevenção & controle , Valor Preditivo dos Testes , Prognóstico , Compostos Radiofarmacêuticos , Radioterapia Adjuvante , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...