Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
2.
Respir Physiol Neurobiol ; 327: 104297, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38871042

RESUMO

Activity-related dyspnea in chronic lung disease is centrally related to dynamic (dyn) inspiratory constraints to tidal volume expansion. Lack of reference values for exertional inspiratory reserve (IR) has limited the yield of cardiopulmonary exercise testing in exposing the underpinnings of this disabling symptom. One hundred fifty apparently healthy subjects (82 males) aged 40-85 underwent incremental cycle ergometry. Based on exercise inspiratory capacity (ICdyn), we generated centile-based reference values for the following metrics of IR as a function of absolute ventilation: IRdyn1 ([1-(tidal volume/ICdyn)] x 100) and IRdyn2 ([1-(end-inspiratory lung volume/total lung capacity] x 100). IRdyn1 and IRdyn2 standards were typically lower in females and older subjects (p<0.05 for sex and age versus ventilation interactions). Low IRdyn1 and IRdyn2 significantly predicted the burden of exertional dyspnea in both sexes (p<0.01). Using these sex and age-adjusted limits of reference, the clinician can adequately judge the presence and severity of abnormally low inspiratory reserves in dyspneic subjects undergoing cardiopulmonary exercise testing.

3.
Respir Care ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834198

RESUMO

BACKGROUND: Continuous monitoring of pulse oximetry (SpO2 ) is recommended during the 6-min walk test (6MWT) to ensure that the lowest SpO2 is recorded. In this case, severe exercise induced desaturation (EID; SpO2 < 80%) triggers walking interruption by the examiner. Our main objective was to assess the impact of this approach on 6MWT distance in patients with chronic respiratory diseases and, second, to evaluate the safety of the test without interruption due to severe EID. METHODS: 6MWTs with continuous monitoring of SpO2 were prospectively performed in subjects with chronic respiratory disease. The participants were randomly allocated to walk with or without SpO2 real-time assessment. SpO2 visualization during the test execution was available only in the first group, and walking interruption was requested by the examiner if SpO2 < 80%. RESULTS: One hundred forty-five participants were included in each group (68.6% females, 62 [52-69] y old) without differences in demographic and resting lung function parameters between them. The main respiratory conditions were COPD (n = 101), asthma (n = 73), pulmonary hypertension (n = 47), and interstitial lung disease (n = 39). The walked distance was similar comparing groups (349.5 ± 117.5 m vs 351.2 ± 105.4 m). Twenty-five subjects presented with severe EID in the group with real-time SpO2 assessment, and 20 subjects had severe EID in the group without real-time assessment respectively (overall prevalence of 15.5%). The 23 participants who had their test interrupted by the examiner due to severe EID in the first group (2 subjects stopped by themselves due to excessive symptoms) walked a shorter distance compared to the 11 subjects with severe EID without test interruption in the second group (9 subjects stopped by themselves due to excessive symptoms): 240.6 ± 100.2 m versus 345.9 ± 73.4 m. No exercise-related serious adverse events were observed. CONCLUSIONS: Interruption driven by severe EID reduced the walked distance during the 6MWT. No serious adverse event, in turn, was observed in subjects with severe desaturation without real-time SpO2 assessment.

5.
Scand J Med Sci Sports ; 34(4): e14625, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38597357

RESUMO

Heightened sensation of leg effort contributes importantly to poor exercise tolerance in patient populations. We aim to provide a sex- and age-adjusted frame of reference to judge symptom's normalcy across progressively higher exercise intensities during incremental exercise. Two-hundred and seventy-five non-trained subjects (130 men) aged 19-85 prospectively underwent incremental cycle ergometry. After establishing centiles-based norms for Borg leg effort scores (0-10 category-ratio scale) versus work rate, exponential loss function identified the centile that best quantified the symptom's severity individually. Peak O2 uptake and work rate (% predicted) were used to threshold gradually higher symptom intensity categories. Leg effort-work rate increased as a function of age; women typically reported higher scores at a given age, particularly in the younger groups (p < 0.05). For instance, "heavy" (5) scores at the 95th centile were reported at ~200 W (<40 years) and ~90 W (≥70 years) in men versus ~130 W and ~70 W in women, respectively. The following categories of leg effort severity were associated with progressively lower exercise capacity: ≤50th ("mild"), >50th to <75th ("moderate"), ≥75th to <95th ("severe"), and ≥ 95th ("very severe") (p < 0.05). Although most subjects reporting peak scores <5 were in "mild" range, higher scores were not predictive of the other categories (p > 0.05). This novel frame of reference for 0-10 Borg leg effort, which considers its cumulative burden across increasingly higher exercise intensities, might prove valuable to judging symptom's normalcy, quantifying its severity, and assessing the effects of interventions in clinical populations.


Assuntos
Teste de Esforço , Perna (Membro) , Masculino , Humanos , Feminino , Valores de Referência , Ergometria , Exercício Físico , Consumo de Oxigênio
6.
Respir Physiol Neurobiol ; 325: 104255, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38555042

RESUMO

The causes and consequences of excess exercise ventilation (EEV) in patients with fibrosing interstitial lung disease (f-ILD) were explored. Twenty-eight adults with f-ILD and 13 controls performed an incremental cardiopulmonary exercise test. EEV was defined as ventilation-carbon dioxide output (⩒E-⩒CO2) slope ≥36 L/L. Patients showed lower pulmonary function and exercise capacity compared to controls. Lower DLCO was related to higher ⩒E-⩒CO2 slope in patients (P<0.05). 13/28 patients (46.4%) showed EEV, reporting higher dyspnea scores (P=0.033). Patients with EEV showed a higher dead space (VD)/tidal volume (VT) ratio while O2 saturation dropped to a greater extent during exercise compared to those without EEV. Higher breathing frequency and VT/inspiratory capacity ratio were observed during exercise in the former group (P<0.05). An exaggerated ventilatory response to exercise in patients with f-ILD is associated with a blunted decrease in the wasted ventilation in the physiological dead space and greater hypoxemia, prompting higher inspiratory constraints and breathlessness.


Assuntos
Teste de Esforço , Exercício Físico , Doenças Pulmonares Intersticiais , Humanos , Doenças Pulmonares Intersticiais/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Exercício Físico/fisiologia , Ventilação Pulmonar/fisiologia , Testes de Função Respiratória , Volume de Ventilação Pulmonar/fisiologia , Dispneia/fisiopatologia , Tolerância ao Exercício/fisiologia
10.
Ann Am Thorac Soc ; 20(10): 1425-1434, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37413694

RESUMO

Rationale: Ventilatory demand-capacity imbalance, as inferred based on a low ventilatory reserve, is currently assessed only at peak cardiopulmonary exercise testing (CPET). Peak ventilatory reserve, however, is poorly sensitive to the submaximal, dynamic mechanical ventilatory abnormalities that are key to dyspnea genesis and exercise intolerance. Objectives: After establishing sex- and age-corrected norms for dynamic ventilatory reserve at progressively higher work rates, we compared peak and dynamic ventilatory reserve for their ability to expose increased exertional dyspnea and poor exercise tolerance in mild to very severe chronic obstructive pulmonary disease (COPD). Methods: We analyzed resting functional and incremental CPET data from 275 controls (130 men, aged 19-85 yr) and 359 Global Initiative for Chronic Obstructive Lung Disease patients with stage 1-4 obstruction (203 men) who were prospectively recruited for previous ethically approved studies in three research centers. In addition to peak and dynamic ventilatory reserve (1 - [ventilation / estimated maximal voluntary ventilation] × 100), operating lung volumes and dyspnea scores (0-10 on the Borg scale) were obtained. Results: Dynamic ventilatory reserve was asymmetrically distributed in controls; thus, we calculated its centile distribution at every 20 W. The lower limit of normal (lower than the fifth centile) was consistently lower in women and older subjects. Peak and dynamic ventilatory reserve disagreed significantly in indicating an abnormally low test result in patients: whereas approximately 50% of those with a normal peak ventilatory reserve showed a reduced dynamic ventilatory reserve, the opposite was found in approximately 15% (P < 0.001). Irrespective of peak ventilatory reserve and COPD severity, patients who had a dynamic ventilatory reserve below the lower limit of normal at an isowork rate of 40 W had greater ventilatory requirements, prompting earlier attainment of critically low inspiratory reserve. Consequently, they reported higher dyspnea scores, showing poorer exercise tolerance compared with those with preserved dynamic ventilatory reserve. Conversely, patients with preserved dynamic ventilatory reserve but reduced peak ventilatory reserve reported the lowest dyspnea scores, showing the best exercise tolerance. Conclusions: Reduced submaximal dynamic ventilatory reserve, even in the setting of preserved peak ventilatory reserve, is a powerful predictor of exertional dyspnea and exercise intolerance in COPD. This new parameter of ventilatory demand-capacity mismatch may enhance the yield of clinical CPET in the investigation of activity-related breathlessness in individual patients with COPD and other prevalent cardiopulmonary diseases.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Masculino , Humanos , Feminino , Valores de Referência , Pulmão , Dispneia/etiologia , Teste de Esforço , Tolerância ao Exercício
12.
J Bras Pneumol ; 49(3): e20220452, 2023.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37255163

RESUMO

OBJECTIVE: To investigate the impact of impaired pulmonary function on patient-centered outcomes after hospital discharge due to severe COVID-19 in patients without preexisting respiratory disease. METHODS: This is an ongoing prospective cohort study evaluating patients (> 18 years of age) 2-6 months after hospital discharge due to severe COVID-19. Respiratory symptoms, health-related quality of life, lung function, and the six-minute walk test were assessed. A restrictive ventilatory defect was defined as TLC below the lower limit of normal, as assessed by plethysmography. Chest CT scans performed during hospitalization were scored for the presence and extent of parenchymal abnormalities. RESULTS: At a mean follow-up of 17.2 ± 5.9 weeks after the diagnosis of COVID-19, 120 patients were assessed. Of those, 23 (19.2%) reported preexisting chronic respiratory diseases and presented with worse lung function and exertional dyspnea at the follow-up visit in comparison with their counterparts. When we excluded the 23 patients with preexisting respiratory disease plus another 2 patients without lung volume measurements, a restrictive ventilatory defect was observed in 42/95 patients (44%). This subgroup of patients (52.4% of whom were male; mean age, 53.9 ± 11.3 years) showed reduced resting gas exchange efficiency (DLCO), increased daily-life dyspnea, increased exertional dyspnea and oxygen desaturation, and reduced health-related quality of life in comparison with those without reduced TLC (50.9% of whom were male; mean age, 58.4 ± 11.3 years). Intensive care need and higher chest CT scores were associated with a subsequent restrictive ventilatory defect. CONCLUSIONS: The presence of a restrictive ventilatory defect approximately 4 months after severe COVID-19 in patients without prior respiratory comorbidities implies worse clinical outcomes.


Assuntos
COVID-19 , Transtornos Respiratórios , Insuficiência Respiratória , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Lactente , Feminino , Testes de Função Respiratória , Estudos Prospectivos , Qualidade de Vida , Dispneia , Sobreviventes
14.
15.
Clin Physiol Funct Imaging ; 43(5): 305-312, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36998164

RESUMO

BACKGROUND: Dysfunctional breathing (DB) is a common, but largely underappreciated, cause of chronic dyspnoea. Under visual inspection, most subjects with DB present with larger sequential changes in ventilation (V̇E) and breathing pattern (tidal volume (VT) and breathing frequency (f)) before and/or during incremental cardiopulmonary exercise testing (CPET). Currently, however, there are no objective criteria to indicate increased ventilatory variability in these subjects. METHODS: Twenty chronically dyspnoeic subjects with DB and 10 age- and sex-matched controls performed CPET on a cycle ergometer. Cut-offs to indicate increased V̇E, VT, f, and f/VT ratio variability (Δ = highest-lowest 20 s arithmetic mean) over the last resting minute (rest ), the 2sd min of unloaded exercise (unload ), and the 3rd min of loaded exercise (load ) were established by ROC curve analyses. RESULTS: Subjects with DB presented with increased V̇E, higher ventilatory variability, higher dyspnoea burden, and lower exercise capacity compared to controls (p < 0.05). ΔV̇Eload (>4.1 L/min), Δfrest (>5 breaths/min; bpm), Δfunload (>4 bpm), Δfload (>5 bpm), Δf/VTrest (>4.9 bpm/L), and Δf/VTload (>1.3 bpm/L) differentiated DB from a normal pattern (areas under the curve ranging from 0.729 to 0.845). High Δf, in particular, was associated with DB across all CPET phases. CONCLUSIONS: This study provides objective criteria to indicate increased ventilatory variability during incremental CPET in dyspnoeic subjects with DB. Large variability in breathing frequency seems particularly useful in this context, a finding that should be prospectively confirmed in larger studies.


Assuntos
Teste de Esforço , Respiração , Humanos , Pulmão , Dispneia/diagnóstico , Volume de Ventilação Pulmonar
16.
ERJ Open Res ; 9(1)2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36726368

RESUMO

Oscillatory ventilation detected on incremental cardiopulmonary exercise testing might be found in subjects without heart failure reporting exertional dyspnoea despite the best available therapy for their underlying cardiopulmonary disease https://bit.ly/3Tyl7bE.

17.
18.
Respir Care ; 68(1): 92-100, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36167849

RESUMO

BACKGROUND: Continuous monitoring of SpO2 throughout the 6-min walk test (6MWT) unveiled that some patients with respiratory diseases may present values across the test lower than SpO2 measured at the end of the test. Nevertheless, it remains unclear whether this approach improves the yield of walk-induced desaturation detection in predicting mortality and hospitalizations in patients with COPD. METHODS: Four hundred twenty-one subjects (51% males) with mild-very severe COPD underwent a 6MWT with continuous measurement of SpO2 . Exercise desaturation was defined as a fall in SpO2 ≥ 4%. All-cause mortality was assessed up to 6 y of follow-up and the rate of hospitalizations in the year succeeding the 6MWT. RESULTS: One hundred forty-nine subjects (35.4%) died during a mean (interquartile) follow-up of 55.5 (30.2-64.1) months. Desaturation was observed in 299/421 (71.0%). SpO2 along the test was < end SpO2 (88 [82-92]% vs 90 [84-93]%, P < .001). Desaturation detected only during (but not at the end of) the test was found in 81/421 (19.2%) participants. Multivariate Cox regression model adjusted for sex, body composition, FEV1, residual volume/total lung capacity ratio, walk distance, O2 supplementation during the test, and comorbidities retained the presence of desaturation either at the end (1.85 [95% CI 1.02-3.36]) or only along the test (2.08 [95% CI 1.09-4.01]) as significant predictors of mortality. The rate of hospitalizations was higher in those presenting with any kind of desaturation compared to those without exercise desaturation. Logistic regression analysis revealed that walking interruption and diffusing capacity of the lung for carbon monoxide predicted desaturation observed only during the test. CONCLUSIONS: O2 desaturation missed by end-exercise SpO2 but exposed by measurements during the test was independently associated with all-cause mortality and hospitalizations in subjects with COPD.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Masculino , Humanos , Feminino , Teste de Caminhada , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Oxigênio , Teste de Esforço , Oximetria , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...