Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet J ; 300-302: 106040, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37898456

RESUMO

Arrhythmias are commonly reported in exercising horses, however due to regulatory constraints electrocardiograms (ECGs) are acquired during training but not competition, raising questions about the repeatability of findings. The aims were (1) compare training and competition arrhythmias and (2) describe the repeatability of arrhythmias during maximal-intensity exercise. A convenience sample of 52 healthy Thoroughbreds (aged 8.7 ± 2.5 years) competing in the World Professional Chuckwagon Association were obtained, totaling 152 training or competition ECGs (2-7 ECGs/horse). Speed, heart rate (HR) and arrhythmias (supraventricular premature complex, SVPC; ventricular premature complex, VPC) were examined. Pre- and post-recovery (approximately 6 min) blood samples measured lactate and high-sensitivity troponin-T. Training and competition arrythmias were compared (Friedman's test) and reliability of repeated ECGs assessed (intraclass correlation; P < 0.05). Training vs. competition: Forty horses had clean tracing from training and competition (n = 80 ECGs); the number and type of arrhythmias were not different. In training, VPCs were present in 7/40 horses (median [interquartile range, IQR]/ECG; range; 0 [0,0]; 0-4) and 9/40 horses (0 [0,0]; 0-5) in active-recovery. In competition, VPCs were present in 7/40 horses (0 [0,0]; 0-8) and 8/40 horses (0 [0,0]; 0-5) in active-recovery. Arrhythmias were primarily single premature complexes. Training and competition speed, HR, lactate and troponin-T did not differ however, sampling was too early for peak serum Troponin-T levels. Repeatability: total arrhythmias between serial ECGs did not differ. The reliability to detect SVPCs and VPCs was poor to moderate, and poor, respectively. Overall, the total number of arrhythmias was repeatable, but the reliability of arrhythmia type was poor to moderate.


Assuntos
Doenças dos Cavalos , Condicionamento Físico Animal , Complexos Ventriculares Prematuros , Cavalos , Animais , Troponina T , Reprodutibilidade dos Testes , Doenças dos Cavalos/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/veterinária , Condicionamento Físico Animal/fisiologia , Lactatos
2.
Vet J ; 267: 105583, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33375959

RESUMO

The prevalence and severity of cardiac arrhythmias in healthy racehorses undergoing competition is not well defined. The aim was to characterize arrhythmias in Thoroughbreds participating in official Chuckwagon races and to determine normal beat-to-beat (R-R) variability during supramaximal exercise. Electrocardiograph (ECG) recordings were obtained during pre-race, race, and active-recovery from 82 clinically healthy Thoroughbreds. ECG recordings were analyzed for arrhythmias and mean percent R-R deviation. Plasma lactate and high-sensitivity troponin (hs-cTnT) were also measured. Fifty-two ECGs were included in the analysis. Arrhythmias were seen in 48/52 horses (92%) and were predominantly isolated events. No complex rhythms were observed. During the race, 92% of horses had arrhythmias (81% supraventricular premature complex [SVPC]; 33% ventricular premature complex [VPC]). Eleven percent of racing arrhythmias were VPCs (all singlets except for two couplets). During active-recovery, 58% of horses had arrhythmias (56% SVPC; 15% VPCs): Three horses had VPC couplets and one horse had a VPC triplet. All plasma hs-cTnT were within normal limits. The measured lactate was 28.5 ± 4.5 mmol/L, confirming supramaximal exercise. R-R variation ranged between -9.5 to +18.8% during pre-race (mean heart rate [HR], 155 ± 22 beats per min [bpm]), -27.8 to +45.3% during racing (mean HR, 200 ± 9 bpm) and -16.4 to +40.1% during active-recovery (mean HR, 165 ± 14 bpm). Maximal and 1st percentile R-R shortening and lengthening were significantly greater at race than pre-race and active-recovery (P < 0.0001). Racing and active-recovery maximal R-R lengthening were significantly greater than pre-race (P = 0.0003). Supraventricular premature complexes and VPCs are prevalent in healthy horses undergoing Chuckwagon racing. R-R variation is greater during racing than has previously been described.


Assuntos
Arritmias Cardíacas/veterinária , Eletrocardiografia/veterinária , Doenças dos Cavalos/epidemiologia , Doenças dos Cavalos/fisiopatologia , Animais , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Complexos Atriais Prematuros/epidemiologia , Complexos Atriais Prematuros/veterinária , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Cavalos , Ácido Láctico/sangue , Masculino , Esforço Físico/fisiologia , Corrida/fisiologia , Troponina T/sangue , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...