Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Shoulder Elbow ; 14(3): 304-316, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35599718

RESUMO

Background: The data on convertible total elbow arthroplasty are limited and primarily based on multiple centre/multiple surgeon series. The aim of this study was to report the mid-term functional outcomes, radiological findings, complications and survivorship of the Latitude total elbow arthroplasty performed by a single surgeon. Study design & methods: The study included 13 patients (10 females, mean age of 72 years and varying indications) over eight years. The Oxford Elbow Score (OES), Mayo Elbow Performance Score (MEPS), range of movements (ROM), Subjective Elbow Value (SEV), satisfaction score (SS) and the revision rate of the implant per 100 observed component years (OCY) were assessed. Results: The mean follow-up was 5.9 years (3-10 years). The Oxford Elbow Score/Mayo Elbow Performance Score improved from 15 to 42 (p value < 0.005)/26% to 93% (p value < 0.005) respectively. The arc of extension-flexion/supination-pronation improved from 63° to 106° (p = 0.00002)/123° to 142° (p = 0.32) respectively. The Subjective Elbow Value/Satisfaction Score was 83/98 respectively. There was one re-operation for a deep infection. There were no radiologic signs of loosening and the revision rate was 0.15 per 100 observed component years. Conclusions: With careful patient selection, convertible total elbow arthroplasty provides patients with good to excellent outcomes and substantial improvements in the range of movements.

2.
Clin Orthop Surg ; 8(4): 373-378, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27904718

RESUMO

BACKGROUND: The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model. METHODS: A uniform 8-mm OWHTO was performed in 12 porcine tibiae. Six of them were subsequently fixed with the plate without a wedge, whereas the other 6 were additionally reinforced with a metal wedge of 8 mm. Biomechanical properties (stiffness, displacement of the osteotomy gap, and failure load) were evaluated under axial load. The different modes of failure were also investigated. RESULTS: The plate showed an axial stiffness of 2,457 ± 450 N/mm with a wedge and 1,969 ± 874 N/mm without a wedge. The maximum failure load was 5,380 ± 952 N with a wedge and 4,354 ± 607 N without a wedge. The plate with a wedge had a significantly greater failure load and significantly less displacement of medial gap at failure than that without a wedge (p = 0.041 and p = 0.002, respectively). The axial stiffness was not different between the two types of fixation. Most failures were caused by lateral cortex breakage and there was no implant failure. CONCLUSIONS: The novel wedge locking plate showed excellent biomechanical properties and an additional wedge provided significant improvement. This plate can be a good fixation method for OWHTO.


Assuntos
Fenômenos Biomecânicos/fisiologia , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Tíbia/cirurgia , Animais , Feminino , Fixação Interna de Fraturas/métodos , Osteotomia/métodos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA