1.
Int J Biol Macromol ; : 133786, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38992551

RESUMO

The poor interfacial compatibility of natural fiber-reinforced polymer composites has become a major challenge in the development of industry-standard high-performance composites. To solve this problem, this study constructs a novel rigid-flexible balanced molecular crosslinked network transition interface in composites. The interface improves the interfacial compatibility of the composites by balancing the stiffness and strength of the fibers and the matrix, effectively improving the properties of the composites. The flexural strength and flexural modulus of the composites were enhanced by 38 % and 44 %, respectively. Water absorption decreased by 30 %. The initial and maximum thermal degradation temperatures increased by 20 °C and 16 °C, respectively. The maximum storage modulus increased by 316 %. Furthermore, the impact toughness was elevated by 41 %, attributed to the crosslinked network's efficacy in absorbing and dissipating externally applied energy. This innovative approach introduces a new theory of interfacial reinforcement compatibility, advancing the development of high-performance and sustainable biocomposites.

2.
Int J Biol Macromol ; 267(Pt 2): 131611, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38641288

RESUMO

Natural plant fiber-reinforced bio-based polymer composites are widely attracting attention because of their economical, readily available, low carbon, and biodegradable, and showing promise in gradually replacing petroleum-based composites. Nevertheless, the fragile interfacial bonding between fiber and substrate hinders the progression of low-cost and abundant sustainable high-performance biocomposites. In this paper, a novel high-performance sustainable biocomposite was built by introducing a high density strong hydrogen-bonded bridging interface based on tannic acid (TA) between bamboo fibers (BFs) and PBSA. Through comprehensive analysis, this strategy endowed the biocomposites with better mechanical properties, thermal stability, dynamic thermo-mechanical properties and water resistance. The optimum performance of the composites was achieved when the TA concentration was 2 g/L. Tensile strength as well as modulus, flexural strength as well as modulus, and impact strength improved by 22 %, 10 %, 15 %, 35 %, and 25 % respectively. Additionally, the initial degradation temperature(Tonset) and maximum degradation temperature(Tmax) increased by 12.07 °C and 14.8 °C respectively. The maximum storage modulus(E'), room temperature E', and loss modulus(E")elevated by 199 %, 75 %, and 181 % respectively. Moreover, the water absorption rate decreased by 59 %. The strong hydrogen-bonded bridging interface serves as a novel model and theory for biocomposite interface engineering. At the same time, it offers a promising future for the development of high performance sustainable biocomposites with low cost and abundant biomass resources and contributes to their wide application in aerospace, automotive, biomedical and other field.


Assuntos
Ligação de Hidrogênio , Taninos , Resistência à Tração , Taninos/química , Temperatura , Materiais Biocompatíveis/química , Sasa/química , Polímeros/química , Água/química , Polifenóis
3.
Int J Biol Macromol ; 259(Pt 1): 129248, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38191108

RESUMO

Marine biological resources, serving as a renewable and sustainable reservoir, holds significant import for the utilization of composite material. Hence, we produced bamboo fiber/poly(3-hydroxybutyrate) (BF/PHB) biocomposites with exceptional performance and economic viability, drawing inspiration from the resilience of crustacean shells. Polyaminoethyl modified chitin (PAECT) was synthesized using the alkali freeze-thaw method and introduced into the interface between BF and PHB to improve interfacial adhesion. The resulting chitin fibers, characterized by their intertwined helical chains, constructed a flexible mesh structure on the BF surface through an electrostatic self-assembly approach. The interwoven PAECT filaments infiltrated the dual-phase structure, acting as a promoter of interfacial compatibility, while the flexible chitin network provided a greater capacity for deformation accommodation. Consequently, both impact and tensile strength of the BF/PHB composites were notably enhanced. Additionally, this flexible layer ameliorated the thermal stability and crystalline properties of the composites. This investigation aimed to leverage the distinctive helical configuration of chitin to facilitate the advancement of bio-reinforced composites.


Assuntos
Quitina , Poliésteres , Poli-Hidroxibutiratos , Poliésteres/química , Ácido 3-Hidroxibutírico , Resistência à Tração
4.
J Cardiothorac Vasc Anesth ; 17(2): 199-203, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12698402

RESUMO

OBJECTIVE: To test the feasibility of continuous cardiac output (CO) monitoring with whole-body impedance cardiography after coronary artery bypass grafting and to compare the values obtained with those measured using the bolus and continuous thermodilution methods. DESIGN: A prospective study. SETTING: Intensive care unit in a university hospital. PATIENTS: Twenty patients after coronary artery bypass grafting. INTERVENTIONS: CO was measured intermittently using the bolus thermodilution method, and continuously using the continuous thermodilution method, and whole-body impedance cardiography immediately after transfer to the intensive care unit. MEASUREMENTS AND MAIN RESULTS: Bolus thermodilution CO was measured in triplicate at up to 14 time points overnight. Continuous thermodilution CO and whole-body impedance cardiography CO values were recorded simultaneously. During the study period, the bias in CO values between bolus thermodilution and whole-body impedance cardiography ranged from 0.07 to 1.05 L/min and the precision (standard deviation of differences) ranged from 0.82 to 1.31 L/min. The bias between the bolus and continuous thermodilution methods ranged from 0.06 to 0.58 L/min and the precision from 0.43 to 1.02 L/min. Pulmonary artery temperature and CO level were the major determinants of the bias and precision in both comparisons. CONCLUSIONS: Agreement between whole-body impedance cardiography and bolus thermodilution is slightly inferior to that between the bolus and continuous thermodilution methods but not to the extent that it hampers the use of whole-body impedance cardiography for the continuous monitoring of CO after coronary artery bypass surgery.


Assuntos
Débito Cardíaco/fisiologia , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Viés , Cardiografia de Impedância/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/estatística & dados numéricos , Período Pós-Operatório , Estudos Prospectivos , Termodiluição/estatística & dados numéricos , Fatores de Tempo