Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Phys Med Biol ; 69(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38588680

RESUMO

Objective.Metal artifacts in computed tomography (CT) images hinder diagnosis and treatment significantly. Specifically, dental cone-beam computed tomography (Dental CBCT) images are seriously contaminated by metal artifacts due to the widespread use of low tube voltages and the presence of various high-attenuation materials in dental structures. Existing supervised metal artifact reduction (MAR) methods mainly learn the mapping of artifact-affected images to clean images, while ignoring the modeling of the metal artifact generation process. Therefore, we propose the bidirectional artifact representations learning framework to adaptively encode metal artifacts caused by various dental implants and model the generation and elimination of metal artifacts, thereby improving MAR performance.Approach.Specifically, we introduce an efficient artifact encoder to extract multi-scale representations of metal artifacts from artifact-affected images. These extracted metal artifact representations are then bidirectionally embedded into both the metal artifact generator and the metal artifact eliminator, which can simultaneously improve the performance of artifact removal and artifact generation. The artifact eliminator learns artifact removal in a supervised manner, while the artifact generator learns artifact generation in an adversarial manner. To further improve the performance of the bidirectional task networks, we propose artifact consistency loss to align the consistency of images generated by the eliminator and the generator with or without embedding artifact representations.Main results.To validate the effectiveness of our algorithm, experiments are conducted on simulated and clinical datasets containing various dental metal morphologies. Quantitative metrics are calculated to evaluate the results of the simulation tests, which demonstrate b-MAR improvements of >1.4131 dB in PSNR, >0.3473 HU decrements in RMSE, and >0.0025 promotion in structural similarity index measurement over the current state-of-the-art MAR methods. All results indicate that the proposed b-MAR method can remove artifacts caused by various metal morphologies and restore the structural integrity of dental tissues effectively.Significance.The proposed b-MAR method strengthens the joint learning of the artifact removal process and the artifact generation process by bidirectionally embedding artifact representations, thereby improving the model's artifact removal performance. Compared with other comparison methods, b-MAR can robustly and effectively correct metal artifacts in dental CBCT images caused by different dental metals.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Metais , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Humanos
2.
IEEE J Biomed Health Inform ; 28(6): 3613-3625, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38478459

RESUMO

Deep learning (DL) algorithms have achieved unprecedented success in low-dose CT (LDCT) imaging and are expected to be a new generation of CT reconstruction technology. However, most DL-based denoising models often lack the ability to generalize to unseen dose data. Moreover, most simulation tools for LDCT typically operate on proprietary projection data, which is generally not accessible without an established collaboration with CT manufacturers. To alleviate these issues, in this work, we propose a dose-agnostic dual-task transfer network, termed DDT-Net, for simultaneous LDCT denoising and simulation. Concretely, the dual-task learning module is constructed to integrate the LDCT denoising and simulation tasks into a unified optimization framework by learning the joint distribution of LDCT and NDCT data. We approximate the joint distribution of continuous dose level data by training DDT-Net with discrete dose data, which can be generalized to denoising and simulation of unseen dose data. In particular, the mixed-dose training strategy adopted by DDT-Net can promote the denoising performance of lower-dose data. The paired dataset simulated by DDT-Net can be used for data augmentation to further restore the tissue texture of LDCT images. Experimental results on synthetic data and clinical data show that the proposed DDT-Net outperforms competing methods in terms of denoising and generalization performance at unseen dose data, and it also provides a simulation tool that can quickly simulate realistic LDCT images at arbitrary dose levels.


Assuntos
Algoritmos , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos
3.
Phys Med Biol ; 69(8)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38422540

RESUMO

Background.Concern has been expressed regarding the risk of carcinogenesis from medical computed tomography (CT) radiation. Lowering radiation in CT without appropriate modifications often leads to severe noise-induced artifacts in the images. The utilization of deep learning (DL) techniques has achieved promising reconstruction performance in low-dose CT (LDCT) imaging. However, most DL-based algorithms require the pre-collection of a large set of image pairs (low-dose/standard-dose) and the training of networks in an end-to-end supervised manner. Meanwhile, securing such a large volume of paired, well-registered training data in clinical practice is challenging. Moreover, these algorithms often overlook the potential to utilize the abundant information in a large collection of LDCT-only images/sinograms.Methods.In this paper, we introduce a semi-supervised iterative adaptive network (SIA-Net) for LDCT imaging, utilizing both labeled and unlabeled sinograms in a cohesive network framework, integrating supervised and unsupervised learning processes. Specifically, the supervised process captures critical features (i.e. noise distribution and tissue characteristics) latent in the paired sinograms, while the unsupervised process effectively learns these features in the unlabeled low-dose sinograms, employing a conventional weighted least-squares model with a regularization term. Furthermore, the SIA-Net method is designed to adaptively transfer the learned feature distribution from the supervised to the unsupervised process, thereby obtaining a high-fidelity sinogram through iterative adaptive learning. Finally, high-quality CT images can be reconstructed from the refined sinogram using the filtered back-projection algorithm.Results.Experimental results on two clinical datasets indicate that the proposed SIA-Net method achieves competitive performance in terms of noise reduction and structure preservation in LDCT imaging, when compared to traditional supervised learning methods.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos
4.
Phys Med Biol ; 68(6)2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36808913

RESUMO

Objective.Metal artifacts in the computed tomography (CT) imaging are unavoidably adverse to the clinical diagnosis and treatment outcomes. Most metal artifact reduction (MAR) methods easily result in the over-smoothing problem and loss of structure details near the metal implants, especially for these metal implants with irregular elongated shapes. To address this problem, we present the physics-informed sinogram completion (PISC) method for MAR in CT imaging, to reduce metal artifacts and recover more structural textures.Approach.Specifically, the original uncorrected sinogram is firstly completed by the normalized linear interpolation algorithm to reduce metal artifacts. Simultaneously, the uncorrected sinogram is also corrected based on the beam-hardening correction physical model, to recover the latent structure information in metal trajectory region by leveraging the attenuation characteristics of different materials. Both corrected sinograms are fused with the pixel-wise adaptive weights, which are manually designed according to the shape and material information of metal implants. To furtherly reduce artifacts and improve the CT image quality, a post-processing frequency split algorithm is adopted to yield the final corrected CT image after reconstructing the fused sinogram.Main results.We qualitatively and quantitatively evaluated the presented PISC method on two simulated datasets and three real datasets. All results demonstrate that the presented PISC method can effectively correct the metal implants with various shapes and materials, in terms of artifact suppression and structure preservation.Significance.We proposed a sinogram-domain MAR method to compensate for the over-smoothing problem existing in most MAR methods by taking advantage of the physical prior knowledge, which has the potential to improve the performance of the deep learning based MAR approaches.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Metais , Física , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
5.
Phys Med Biol ; 67(24)2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36351294

RESUMO

Objective.Deep neural network (DNN) based methods have shown promising performances for low-dose computed tomography (LDCT) imaging. However, most of the DNN-based methods are trained on simulated labeled datasets, and the low-dose simulation algorithms are usually designed based on simple statistical models which deviate from the real clinical scenarios, which could lead to issues of overfitting, instability and poor robustness. To address these issues, in this work, we present a structure-preserved meta-learning uniting network (shorten as 'SMU-Net') to suppress noise-induced artifacts and preserve structure details in the unlabeled LDCT imaging task in real scenarios.Approach.Specifically, the presented SMU-Net contains two networks, i.e., teacher network and student network. The teacher network is trained on simulated labeled dataset and then helps the student network train with the unlabeled LDCT images via the meta-learning strategy. The student network is trained on real LDCT dataset with the pseudo-labels generated by the teacher network. Moreover, the student network adopts the Co-teaching strategy to improve the robustness of the presented SMU-Net.Main results.We validate the proposed SMU-Net method on three public datasets and one real low-dose dataset. The visual image results indicate that the proposed SMU-Net has superior performance on reducing noise-induced artifacts and preserving structure details. And the quantitative results exhibit that the presented SMU-Net method generally obtains the highest signal-to-noise ratio (PSNR), the highest structural similarity index measurement (SSIM), and the lowest root-mean-square error (RMSE) values or the lowest natural image quality evaluator (NIQE) scores.Significance.We propose a meta learning strategy to obtain high-quality CT images in the LDCT imaging task, which is designed to take advantage of unlabeled CT images to promote the reconstruction performance in the LDCT environments.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Algoritmos
6.
Phys Med Biol ; 67(18)2022 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-35926503

RESUMO

Computed tomography perfusion (CTP) is a functional imaging that allows for providing capillary-level hemodynamics information of the desired tissue in clinics. In this paper, we aim to offer insight into CTP imaging which covers the basics and current state of CTP imaging, then summarize the technical applications in the CTP imaging as well as the future technological potential. At first, we focus on the fundamentals of CTP imaging including systematically summarized CTP image acquisition and hemodynamic parameter map estimation techniques. A short assessment is presented to outline the clinical applications with CTP imaging, and then a review of radiation dose effect of the CTP imaging on the different applications is presented. We present a categorized methodology review on known and potential solvable challenges of radiation dose reduction in CTP imaging. To evaluate the quality of CTP images, we list various standardized performance metrics. Moreover, we present a review on the determination of infarct and penumbra. Finally, we reveal the popularity and future trend of CTP imaging.


Assuntos
Imagem de Perfusão , Tomografia Computadorizada por Raios X , Perfusão , Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X/métodos
7.
IEEE Trans Med Imaging ; 41(12): 3849-3861, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35939459

RESUMO

Deep learning (DL)-based methods show great potential in computed tomography (CT) imaging field. The DL-based reconstruction methods are usually evaluated on the training and testing datasets which are obtained from the same distribution, i.e., the same CT scan protocol (i.e., the region setting, kVp, mAs, etc.). In this work, we focus on analyzing the robustness of the DL-based methods against protocol-specific distribution shifts (i.e., the training and testing datasets are from different region settings, different kVp settings, or different mAs settings, respectively). The results show that the DL-based reconstruction methods are sensitive to the protocol-specific perturbations which can be attributed to the noise distribution shift between the training and testing datasets. Based on these findings, we presented a low-dose CT reconstruction method using an unsupervised strategy with the consideration of noise distribution to address the issue of protocol-specific perturbations. Specifically, unpaired sinogram data is enrolled into the network training, which represents unique information for specific imaging protocol, and a Gaussian mixture model (GMM) is introduced to characterize the noise distribution in CT images. It can be termed as GMM based unsupervised CT reconstruction network (GMM-unNet) method. Moreover, an expectation-maximization algorithm is designed to optimize the presented GMM-unNet method. Extensive experiments are performed on three datasets from different scan protocols, which demonstrate that the presented GMM-unNet method outperforms the competing methods both qualitatively and quantitatively.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Distribuição Normal , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
Phys Med Biol ; 67(11)2022 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-35523153

RESUMO

Objective.The radiation dose of cerebral perfusion computed tomography (CPCT) imaging can be reduced by lowering the milliampere-second or kilovoltage peak. However, dose reduction can decrease image quality due to excessive x-ray quanta fluctuation and reduced detector signal relative to system electronic noise, thereby influencing the accuracy of hemodynamic parameters for patients with acute stroke. Existing low-dose CPCT denoising methods, which mainly focus on specific temporal and spatial prior knowledge in low-dose CPCT images, not take the noise distribution characteristics of low-dose CPCT images into consideration. In practice, the noise of low-dose CPCT images can be much more complicated. This study first investigates the noise properties in low-dose CPCT images and proposes a perfusion deconvolution model based on the noise properties.Approach.To characterize the noise distribution in CPCT images properly, we analyze noise properties in low-dose CPCT images and find that the intra-frame noise distribution may vary in the different areas and the inter-frame noise also may vary in low-dose CPCT images. Thus, we attempt the first-ever effort to model CPCT noise with a non-independent and identical distribution (i.i.d.) mixture-of-Gaussians (MoG) model for noise assumption. Furthermore, we integrate the noise modeling strategy into a perfusion deconvolution model and present a novel perfusion deconvolution method by using self-relative structural similarity information and MoG model (named as SR-MoG) to estimate the hemodynamic parameters accurately. In the presented SR-MoG method, the self-relative structural similarity information is obtained from preprocessed low-dose CPCT images.Main results.The results show that the presented SR-MoG method can achieve promising gains over the existing deconvolution approaches. In particular, the average root-mean-square error (RMSE) of cerebral blood flow (CBF), cerebral blood volume, and mean transit time was improved by 40.3%, 69.1%, and 40.8% in the digital phantom study, and the average RMSE of CBF can be improved by 81.0% in the clinical data study, compared with tensor total variation regularization deconvolution method.Significance.The presented SR-MoG method can estimate high-accuracy hemodynamic parameters andachieve promising gains over the existing deconvolution approaches.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador/métodos , Perfusão , Imagens de Fantasmas , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
9.
Phys Med Biol ; 66(14)2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34181588

RESUMO

Dynamic CT myocardial perfusion imaging (DCT-MPI) is a reliable examination tool for the assessment of myocardium and vascular, while its special scan protocol may result in excessive radiation exposure to patients and inevitable inter-frame motion. Lowering the tube current is a simple way to reduce radiation exposure. However, low mAs will certainly cause severe image noise, thus may further impact the accuracy of functional hemodynamic parameters, which are used for the assessment of blood supply. In this work, we present a novel scheme applying motion compensation and local low rank regularization (MC-LLR) for obtaining high quality motion compensated DCT-MPI images. Specifically, motion compensation by using robust data decomposition registration (RDDR) was introduced. Robust principal component analysis coupled with optical flow-based registration algorithm were used in RDDR. Then, the local low rank constraint on the motion compensated time series images was applied for the DCT-MPI reconstruction. One healthy mini pig and two patient datasets were used to evaluate the proposed MC-LLR algorithm. Results show that the present method achieved satisfactory image quality with higher CNRs, smaller rRMSEs, and more accurate hemodynamic parameter maps.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia Computadorizada por Raios X , Algoritmos , Animais , Humanos , Processamento de Imagem Assistida por Computador , Miocárdio , Perfusão , Imagens de Fantasmas , Suínos , Porco Miniatura
10.
Phys Med Biol ; 66(11)2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-33910178

RESUMO

Background. Computed tomography perfusion (CTP) imaging plays a critical role in the acute stroke syndrome assessment due to its widespread availability, speed of image acquisition, and relatively low cost. However, due to its repeated scanning protocol, CTP imaging involves a substantial radiation dose, which might increase potential cancer risks.Methods. In this work, we present a novel deep learning model called non-local perfusion texture learning network (NPTN) for high-quality CTP imaging at low-dose cases. Specifically, considering abundant similarities in the CTP images, i.e. latent self-similarities within the non-local region in the CTP images, we firstly search the most similar pixels from the adjacent frames within a fixed search window to obtain the non-local similarities and to construct non-local textures vector. Then, both the low-dose frame and these non-local textures from adjacent frames are fed into a convolution neural network to predict high-quality CTP images, which can help better characterize the structure details and contrast variants in the targeted CTP image rather than simply utilizing the targeted frame itself. The residual learning strategy and batch normalization are utilized to boost the performance of the convolution neural network. In the experiment, the CTP images of 31 patients with suspected stroke disease are collected to demonstrate the performance of the presented NPTN method.Results. The results show the presented NPTN method obtains superior performance compared with the competing methods. From numerical value, at all dose levels, the presented NPTN method has achieved around 3.0 dB improvement of average PSNR, an increase of around 1.4% of average SSIM, and a decrease of around 4.8% of average RMSE in the low-dose CTP reconstruction task, and also has achieved an increase of around 3.4% of average SSIM and a decrease of around 61.1% of average RMSE in the cerebral blood flow (CBF) estimation task.Conclusions. The presented NPTN method can obtain high-quality CTP images and estimate high-accuracy CBF map by characterizing more structure details and contrast variants in the CTP image and outperform the competing methods at low-dose cases.


Assuntos
Acidente Vascular Cerebral , Tomografia Computadorizada por Raios X , Circulação Cerebrovascular , Humanos , Perfusão , Imagem de Perfusão , Acidente Vascular Cerebral/diagnóstico por imagem
11.
IEEE Trans Comput Imaging ; 6: 1375-1388, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33313342

RESUMO

Perfusion computed tomography (PCT) is critical in detecting cerebral ischemic lesions. PCT examination with low-dose scans can effectively reduce radiation exposure to patients at the cost of degraded images with severe noise and artifacts. Tensor total variation (TTV) models are powerful tools that can encode the regional continuous structures underlying a PCT object. In a TTV model, the sparsity structures of the contrast-medium concentration (CMC) across PCT frames are assumed to be isotropic with identical and independent distribution. However, this assumption is inconsistent with practical PCT tasks wherein the sparsity has evident variations and correlations. Such modeling deviation hampers the performance of TTV-based PCT reconstructions. To address this issue, we developed a novel contrast-medium anisotropy-aware tensor total variation (CMAA-TTV) model to describe the intrinsic anisotropy sparsity of the CMC in PCT imaging tasks. Instead of directly on the difference matrices, the CMAA-TTV model characterizes sparsity on a low-rank subspace of the difference matrices which are calculated from the input data adaptively, thus naturally encoding the intrinsic variant and correlated anisotropy sparsity structures of the CMC. We further proposed a robust and efficient PCT reconstruction algorithm to improve low-dose PCT reconstruction performance using the CMAA-TTV model. Experimental studies using a digital brain perfusion phantom, patient data with low-dose simulation and clinical patient data were performed to validate the effectiveness of the presented algorithm. The results demonstrate that the CMAA-TTV algorithm can achieve noticeable improvements over state-of-the-art methods in low-dose PCT reconstruction tasks.

12.
IEEE Trans Med Imaging ; 39(11): 3630-3642, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32746110

RESUMO

Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substantially degrade the reconstruction performance and material estimation accuracy. To address these issues, in this work, we present a novel system for high-performance spectral PCCT imaging, which is a combination of multiple dynamic modulations, interpolation-based measurements processing strategy and advanced reconstruction method. For simplicity, this new PCCT imaging system is referred to as "MDM-PCCT". Specifically, the multiple dynamic modulations consist of dynamic kVp modulation, dynamic spectrum modulation and dynamic energy threshold modulation. In the dynamic kVp modulation, three kVp values, i.e., 80, 110 and 140, are included, and the tube voltage waveform follows a sinusoidal curve which is more practical than the rectangular curve in the fast kV switching mode. In the dynamic spectrum modulation, the X-ray spectra are processed by selective spatial-spectral filters to balance the X-ray fluxes and increase the spectral separation. In the dynamic energy threshold modulation, the energy threshold is adaptively changed to determine the optimal bin selection. Furthermore, we propose an energy threshold determination method and interpolation-based measurements processing strategy to address the issue of non-uniform and sparse-view PCCT measurements, respectively. In addition, by considering the intrinsic characteristics of the MDM-PCCT images, we utilize an enhanced total variation regularized model for images reconstruction. Finally, numerical and preclinical studies demonstrate that the presented MDM-PCCT imaging system is capable of yielding uniform and high-fidelity PCCT measurements with noise consistency, and the presented reconstruction method further improves the image quality and material decomposition accuracy.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Raios X
13.
IEEE Trans Med Imaging ; 39(9): 2831-2843, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32112677

RESUMO

Energy-resolved computed tomography (ErCT) with a photon counting detector concurrently produces multiple CT images corresponding to different photon energy ranges. It has the potential to generate energy-dependent images with improved contrast-to-noise ratio and sufficient material-specific information. Since the number of detected photons in one energy bin in ErCT is smaller than that in conventional energy-integrating CT (EiCT), ErCT images are inherently more noisy than EiCT images, which leads to increased noise and bias in the subsequent material estimation. In this work, we first deeply analyze the intrinsic tensor properties of two-dimensional (2D) ErCT images acquired in different energy bins and then present a F ull- S pectrum-knowledge-aware Tensor analysis and processing (FSTensor) method for ErCT reconstruction to suppress noise-induced artifacts to obtain high-quality ErCT images and high-accuracy material images. The presented method is based on three considerations: (1) 2D ErCT images obtained in different energy bins can be treated as a 3-order tensor with three modes, i.e., width, height and energy bin, and a rich global correlation exists among the three modes, which can be characterized by tensor decomposition. (2) There is a locally piecewise smooth property in the 3-order ErCT images, and it can be captured by a tensor total variation regularization. (3) The images from the full spectrum are much better than the ErCT images with respect to noise variance and structural details and serve as external information to improve the reconstruction performance. We then develop an alternating direction method of multipliers algorithm to numerically solve the presented FSTensor method. We further utilize a genetic algorithm to tackle the parameter selection in ErCT reconstruction, instead of manually determining parameters. Simulation, preclinical and synthesized clinical ErCT results demonstrate that the presented FSTensor method leads to significant improvements over the filtered back-projection, robust principal component analysis, tensor-based dictionary learning and low-rank tensor decomposition with spatial-temporal total variation methods.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Algoritmos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
14.
Nan Fang Yi Ke Da Xue Xue Bao ; 39(11): 1320-1328, 2019 Nov 30.
Artigo em Chinês | MEDLINE | ID: mdl-31852651

RESUMO

OBJECTIVE: Sparse-view CT has the advantages of accelerated data collection and reduced radiation dose, but data missing arising from the data collection process causes serious streaking artifact and noise in the images reconstructed using the traditional filtering back projection algorithm (FBP). To solve this problem, we propose a multi-scale wavelet residual network (MWResNet) to restore sparse-view CT images. METHODS: The MWResNet was based on the combination of deep learning and traditional model in MWCNN, and the wavelet network was combined with the residual block to enhance the network's ability to embed image features and speed up network training. The network proposed herein was trained using the real spiral geometry CT image data, namely the Low-dose CT Grand Challenge dataset. The results of the proposed networks were visually and quantitatively compared to that by other existing networks, including the image restoration iterative residual convolution network (IRLNet), residual coding-decoding convolutional neural network (REDCNN) and the FBP convolutional neural network (FBPConvNet). RESULTS: The results demonstrated that the proposed method was superior to other competing methods in terms of visual inspection and quantitative comparison. CONCLUSIONS: The MWResNet network is an effective method for suppressing noise and artifacts and maintaining edges details in the sparse-view CT images.


Assuntos
Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Processamento de Imagem Assistida por Computador , Redes Neurais de Computação
15.
Nan Fang Yi Ke Da Xue Xue Bao ; 39(10): 1213-1220, 2019 Oct 30.
Artigo em Chinês | MEDLINE | ID: mdl-31801709

RESUMO

OBJECTIVE: We propose a sparse-view helical CT iterative reconstruction algorithm based on projection of convex set tensor total generalized variation minimization (TTGV-POCS) to reduce the X-ray dose of helical CT scanning. METHODS: The three-dimensional volume data of helical CT reconstruction was viewed as the third-order tensor. The tensor generalized total variation (TTGV) was used to describe the structural sparsity of the three-dimensional image. The POCS iterative reconstruction framework was adopted to achieve a robust result of sparse-view helical CT reconstruction. The TTGV-POCS algorithm fully used the structural sparsity of first-order and second-order derivation and the correlation between the slices of helical CT image data to effectively suppress artifacts and noise in the image of sparse-view reconstruction and better preserve image edge information. RESULTS: The experimental results of XCAT phantom and patient scan data showed that the TTGVPOCS algorithm had better performance in reducing noise, removing artifacts and maintaining edges than the existing reconstruction algorithms. Comparison of the sparse-view reconstruction results of XCAT phantom data with 144 exposure views showed that the TTGV-POCS algorithm proposed herein increased the PSNR quantitative index by 9.17%-15.24% compared with the experimental comparison algorithm; the FSIM quantitative index was increased by 1.27%-9.30%. CONCLUSIONS: The TTGV-POCS algorithm can effectively improve the image quality of helical CT sparse-view reconstruction and reduce the radiation dose of helical CT examination to improve the clinical imaging diagnosis.


Assuntos
Processamento de Imagem Assistida por Computador , Doses de Radiação , Tomografia Computadorizada Espiral , Algoritmos , Humanos , Imagens de Fantasmas
16.
Nan Fang Yi Ke Da Xue Xue Bao ; 39(2): 192-200, 2019 02 28.
Artigo em Chinês | MEDLINE | ID: mdl-30890508

RESUMO

OBJECTIVE: To develop a digital breast tomosynthesis (DBT) imaging system with optimizes imaging chain. METHODS: Based on 3D tomography and DBT imaging scanning, we analyzed the methods for projection data correction, geometric correction, projection enhancement, filter modulation, and image reconstruction, and established a hardware testing platform. In the experiment, the standard ACR phantom and high-resolution phantom were used to evaluate the system stability and noise level. The patient projection data of commercial equipment was used to test the effect of the imaging algorithm. RESULTS: In the high-resolution phantom study, the line pairs were clear without confusing artifacts in the images reconstructed with the geometric correction parameters. In ACR phantom study, the calcified foci, cysts, and fibrous structures were more clearly defined in the reconstructed images after filtering and modulation. The patient data study showed a high contrast between tissues, and the lesions were more clearly displayed in the reconstructed image. CONCLUSIONS: This DBT imaging system can be used for mammary tomography with an image quality comparable to that of commercial DBT systems to facilitate imaging diagnosis of breast diseases.


Assuntos
Mama/diagnóstico por imagem , Mamografia/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Algoritmos , Artefatos , Feminino , Humanos
17.
Nan Fang Yi Ke Da Xue Xue Bao ; 39(1): 88-92, 2019 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-30692072

RESUMO

OBJECTIVE: To develop a deep features-based model to classify benign and malignant breast lesions on full- filed digital mammography. METHODS: The data of full-filed digital mammography in both craniocaudal view and mediolateral oblique view from 106 patients with breast neoplasms were analyzed. Twenty-three handcrafted features (HCF) were extracted from the images of the breast tumors and a suitable feature set of HCF was selected using t-test. The deep features (DF) were extracted from the 3 pre-trained deep learning models, namely AlexNet, VGG16 and GoogLeNet. With abundant breast tumor information from the craniocaudal view and mediolateral oblique view, we combined the two extracted features (DF and HCF) as the two-view features. A multi-classifier model was finally constructed based on the combined HCF and DF sets. The classification ability of different deep learning networks was evaluated. RESULTS: Quantitative evaluation results showed that the proposed HCF+DF model outperformed HCF model, and AlexNet produced the best performances among the 3 deep learning models. CONCLUSIONS: The proposed model that combines DF and HCF sets of breast tumors can effectively distinguish benign and malignant breast lesions on full-filed digital mammography.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Aprendizado Profundo , Diagnóstico por Computador/métodos , Mamografia/métodos , Neoplasias da Mama/classificação , Feminino , Humanos
18.
IEEE Trans Med Imaging ; 38(2): 371-382, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30106717

RESUMO

Reducing the exposure to X-ray radiation while maintaining a clinically acceptable image quality is desirable in various CT applications. To realize low-dose CT (LdCT) imaging, model-based iterative reconstruction (MBIR) algorithms are widely adopted, but they require proper prior knowledge assumptions in the sinogram and/or image domains and involve tedious manual optimization of multiple parameters. In this paper, we propose a deep learning (DL)-based strategy for MBIR to simultaneously address prior knowledge design and MBIR parameter selection in one optimization framework. Specifically, a parameterized plug-and-play alternating direction method of multipliers (3pADMM) is proposed for the general penalized weighted least-squares model, and then, by adopting the basic idea of DL, the parameterized plug-and-play (3p) prior and the related parameters are optimized simultaneously in a single framework using a large number of training data. The main contribution of this paper is that the 3p prior and the related parameters in the proposed 3pADMM framework can be supervised and optimized simultaneously to achieve robust LdCT reconstruction performance. Experimental results obtained on clinical patient datasets demonstrate that the proposed method can achieve promising gains over existing algorithms for LdCT image reconstruction in terms of noise-induced artifact suppression and edge detail preservation.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Bases de Dados Factuais , Aprendizado Profundo , Humanos , Radiografia Torácica
19.
IEEE Trans Med Imaging ; 38(2): 360-370, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30106716

RESUMO

Cerebrovascular diseases, i.e., acute stroke, are a common cause of serious long-term disability. Cerebral perfusion computed tomography (CPCT) can provide rapid, high-resolution, quantitative hemodynamic maps to assess and stratify perfusion in patients with acute stroke symptoms. However, CPCT imaging typically involves a substantial radiation dose due to its repeated scanning protocol. Therefore, in this paper, we present a low-dose CPCT image reconstruction method to yield high-quality CPCT images and high-precision hemodynamic maps by utilizing the great similarity information among the repeated scanned CPCT images. Specifically, a newly developed low-rank tensor decomposition with spatial-temporal total variation (LRTD-STTV) regularization is incorporated into the reconstruction model. In the LRTD-STTV regularization, the tensor Tucker decomposition is used to describe global spatial-temporal correlations hidden in the sequential CPCT images, and it is superior to the matricization model (i.e., low-rank model) that fails to fully investigate the prior knowledge of the intrinsic structures of the CPCT images after vectorizing the CPCT images. Moreover, the spatial-temporal TV regularization is used to characterize the local piecewise smooth structure in the spatial domain and the pixels' similarity with the adjacent frames in the temporal domain, because the intensity at each pixel in CPCT images is similar to its neighbors. Therefore, the presented LRTD-STTV model can efficiently deliver faithful underlying information of the CPCT images and preserve the spatial structures. An efficient alternating direction method of multipliers algorithm is also developed to solve the presented LRTD-STTV model. Extensive experimental results on numerical phantom and patient data are clearly demonstrated that the presented model can significantly improve the quality of CPCT images and provide accurate diagnostic features in hemodynamic maps for low-dose cases compared with the existing popular algorithms.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Circulação Cerebrovascular/fisiologia , Humanos , Imagens de Fantasmas
20.
Phys Med Biol ; 64(3): 035018, 2019 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-30577033

RESUMO

Multi-energy computed tomography (MECT) is able to acquire simultaneous multi-energy measurements from one scan. In addition, it allows material differentiation and quantification effectively. However, due to the limited energy bin width, the number of photons detected in an energy-specific channel is smaller than that in traditional CT, which results in image quality degradation. To address this issue, in this work, we develop a statistical iterative reconstruction algorithm to acquire high-quality MECT images and high-accuracy material-specific images. Specifically, this algorithm fully incorporates redundant self-similarities within nonlocal regions in the MECT image at one bin and rich spectral similarities among MECT images at all bins. For simplicity, the presented algorithm is referred to as 'MECT-NSS'. Moreover, an efficient optimization algorithm is developed to solve the MECT-NSS objective function. Then, a comprehensive evaluation of parameter selection for the MECT-NSS algorithm is conducted. In the experiment, the datasets include images from three phantoms and one patient to validate and evaluate the MECT-NSS reconstruction performance. The qualitative and quantitative results demonstrate that the presented MECT-NSS can successfully yield better MECT image quality and more accurate material estimation than the competing algorithms.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Modelos Estatísticos , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Imagens de Fantasmas , Fótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...