Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bone Joint J ; 100-B(5): 667-674, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29701102

RESUMO

Aims: The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use. Patients and Methods: We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74). Results: Donor-site morbidity occurred in four patients (4%; 95% confidence interval (CI) 1 to 10). One patient had a stress fracture of the tibia, which healed with a varus deformity, requiring an osteotomy. Two patients required evacuation of a haematoma and one developed anterior compartment syndrome which required fasciotomies. The cumulative probability of union was 90% (95% CI 80 to 96) at five years. The type of reconstruction (p = 0.018), continuity of bone (p = 0.006) and length of tibial graft (p = 0.037) were associated with the time to union. Conclusion: The tibial strut autograft has a low risk of morbidity and provides adequate bone stock for treating various defects of long bones. Cite this article: Bone Joint J 2018;100-B:667-74.


Assuntos
Doenças Ósseas/cirurgia , Transplante Ósseo , Tíbia/transplante , Sítio Doador de Transplante , Ferimentos e Lesões/cirurgia , Adulto , Autoenxertos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade , Estudos Retrospectivos , Ferida Cirúrgica/cirurgia , Tíbia/fisiopatologia , Transplante Autólogo , Adulto Jovem
2.
Bone Joint J ; 97-B(2): 177-84, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25628279

RESUMO

Conventional cemented acetabular components are reported to have a high rate of failure when implanted into previously irradiated bone. We recommend the use of a cemented reconstruction with the addition of an acetabular reinforcement cross to improve fixation. We reviewed a cohort of 45 patients (49 hips) who had undergone irradiation of the pelvis and a cemented total hip arthroplasty (THA) with an acetabular reinforcement cross. All hips had received a minimum dose of 30 Gray (Gy) to treat a primary nearby tumour or metastasis. The median dose of radiation was 50 Gy (Q1 to Q3: 45 to 60; mean: 49.57, 32 to 72). The mean follow-up after THA was 51 months (17 to 137). The cumulative probability of revision of the acetabular component for a mechanical reason was 0% (0 to 0%) at 24 months, 2.9% (0.2 to 13.3%) at 60 months and 2.9% (0.2% to 13.3%) at 120 months, respectively. One hip was revised for mechanical failure and three for infection. Cemented acetabular components with a reinforcement cross provide good medium-term fixation after pelvic irradiation. These patients are at a higher risk of developing infection of their THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ossos Pélvicos/efeitos da radiação , Desenho de Prótese , Neoplasias Urogenitais/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Neoplasias Ósseas/radioterapia , Cimentação , Feminino , Neoplasias Femorais/cirurgia , Necrose da Cabeça do Fêmur/cirurgia , Fraturas Espontâneas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteíte/cirurgia , Estudos Retrospectivos , Neoplasias Ureterais/radioterapia , Neoplasias da Bexiga Urinária/cirurgia
3.
J Bone Joint Surg Br ; 93(9): 1183-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21911528

RESUMO

The purpose of this study was to define immediate post-operative 'quality' in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.


Assuntos
Artroplastia de Quadril/normas , Competência Clínica , Avaliação de Processos e Resultados em Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Humanos , Complicações Pós-Operatórias , Estudos Prospectivos , Falha de Tratamento
4.
J Bone Joint Surg Br ; 93(8): 1093-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21768635

RESUMO

Pathological fractures of the humerus are associated with pain, morbidity, loss of function and a diminished quality of life. We report our experience of stabilising these fractures using polymethylmethacrylate and non-locking plates. We undertook a retrospective review over 20 years of patients treated at a tertiary musculoskeletal oncology centre. Those who had undergone surgery for an impending or completed pathological humeral fracture with a diagnosis of metastatic disease or myeloma were identified from our database. There were 63 patients (43 men, 20 women) in the series with a mean age of 63 years (39 to 87). All had undergone intralesional curettage of the tumour followed by fixation with intramedullary polymethylmethacrylate and plating. Complications occurred in 14 patients (22.2%) and seven (11.1%) required re-operation. At the latest follow-up, 47 patients (74.6%) were deceased and 16 (25.4%) were living with a mean follow-up of 75 months (1 to 184). A total of 54 (86%) patients had no or mild pain and 50 (80%) required no or minimal assistance with activities of daily living. Of the 16 living patients none had pain and all could perform activities of daily living without assistance. Intralesional resection of the tumour, filling of the cavity with cement, and plate stabilisation of the pathological fracture gives immediate rigidity and allows an early return of function without the need for bony union. The patient's local disease burden is reduced, which may alleviate tumour-related pain and slow the progression of the disease. The cemented-plate technique provides a reliable option for the treatment of pathological fractures of the humerus.


Assuntos
Placas Ósseas , Fixação Intramedular de Fraturas/métodos , Fraturas do Úmero/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/complicações , Neoplasias Ósseas/secundário , Neoplasias Ósseas/cirurgia , Cimentação , Feminino , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas Espontâneas/diagnóstico por imagem , Fraturas Espontâneas/etiologia , Fraturas Espontâneas/cirurgia , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/etiologia , Masculino , Pessoa de Meia-Idade , Polimetil Metacrilato , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
6.
Br J Surg ; 95(7): 925-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18498126

RESUMO

BACKGROUND: Current methods available for assessing the learning curve, such as a predefined number of procedures or direct observation by a tutor, are unsatisfactory. A new tool, the cumulative summation test for learning curve (LC-CUSUM), has been developed that allows quantitative and individual assessment of the learning curve. METHODS: Some 532 endoscopic retrograde cholangiopancreatographies (ERCPs) performed by one endoscopist over 8 years were analysed retrospectively using LC-CUSUM to assess the learning curve. The procedure was new to the endoscopist and monitored prospectively in the initial study. Success of the procedure was defined as cannulation and proper visualization of the duct(s) selected before the examination. RESULTS: Fifty ERCPs were considered unsuccessful. There was a gradual improvement in performance over time from a success rate of 82.0 per cent for the first 100 procedures to 96.1 per cent for the last 129 procedures. The LC-CUSUM signalled at the 79th procedure, indicating that sufficient evidence had accumulated to prove that the endoscopist was competent. CONCLUSION: LC-CUSUM allows quantitative monitoring of individual performance during the learning process.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/normas , Competência Clínica/normas , Educação Médica Continuada , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...