Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 182(3): 310-316, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590841

RESUMO

Our goal was to define a pediatric head CT protocol able to provide images of diagnostic quality, using the least amount of radiation, in children <10 years of age, while using a filtered back projection reconstruction algorithm. Image quality of 119 pediatric head CTs was assessed using a 5-point scoring system. Exams with scores ≥2.5 were considered of sufficient diagnostic quality. The contrast-to-noise ratio (CNR) was also measured. For children <1 year and 1-9 years, all studies performed with CTDIvol ≥ 20.1 mGy (range: 9-46 mGy) and CTDIvol ≥ 27.5 mGy (range: 15-60 mGy) yielded images of diagnostic quality. All diagnostic studies had a minimum CNR of 1.4. These CTDIvol values represent a good balance between image quality and radiation burden. This information can be helpful in designing pediatric head CT protocols with further dose-reduction, namely, iterative reconstruction algorithms and automated exposure control.


Assuntos
Cabeça/diagnóstico por imagem , Monitoramento de Radiação/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Controle de Qualidade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
2.
Geriatr Orthop Surg Rehabil ; 8(4): 263-267, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29318090

RESUMO

In posterior spinal fusion (PSF), the vertebral artery is most vulnerable to injury at C1-2. C2 pedicle screws are often placed into the dorsomedial isthmus of C2. Alternative techniques include C2 laminar screws and wiring techniques. A 67-year-old male underwent PSF for persistent severe intractable neck pain and degeneration at C1-2. The patient had an enlarged left vertebral artery with midline migration into the C2 body. This pattern was within one standard deviation of normal; however, it rendered typical placement of a C2 pedicle screw unsafe. As a salvage, a C2 laminar screw was placed on the left to avoid risk of vertebral artery injury. The operation and recovery were without complication. C2 laminar screws can be viable alternatives to C2 pedicle screws in cases of midline vertebral artery migration or other vascular anomalies preventing normal safe placement of C2 pedicle screws.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA