Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Trends Hear ; 202016 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-27317668

RESUMO

Speech perception among cochlear implant (CI) listeners is highly variable. High degrees of channel interaction are associated with poorer speech understanding. Two methods for reducing channel interaction, focusing electrical fields, and deactivating subsets of channels were assessed by the change in vowel and consonant identification scores with different program settings. The main hypotheses were that (a) focused stimulation will improve phoneme recognition and (b) speech perception will improve when channels with high thresholds are deactivated. To select high-threshold channels for deactivation, subjects' threshold profiles were processed to enhance the peaks and troughs, and then an exclusion or inclusion criterion based on the mean and standard deviation was used. Low-threshold channels were selected manually and matched in number and apex-to-base distribution. Nine ears in eight adult CI listeners with Advanced Bionics HiRes90k devices were tested with six experimental programs. Two, all-channel programs, (a) 14-channel partial tripolar (pTP) and (b) 14-channel monopolar (MP), and four variable-channel programs, derived from these two base programs, (c) pTP with high- and (d) low-threshold channels deactivated, and (e) MP with high- and (f) low-threshold channels deactivated, were created. Across subjects, performance was similar with pTP and MP programs. However, poorer performing subjects (scoring < 62% correct on vowel identification) tended to perform better with the all-channel pTP than with the MP program (1 > 2). These same subjects showed slightly more benefit with the reduced channel MP programs (5 and 6). Subjective ratings were consistent with performance. These finding suggest that reducing channel interaction may benefit poorer performing CI listeners.


Assuntos
Implantes Cocleares , Percepção da Fala , Biônica , Implante Coclear , Surdez , Humanos , Fenômenos Físicos
3.
Trends Hear ; 202016 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-27194155

RESUMO

The 10 consonant-nucleus-consonant (CNC) word lists are considered the gold standard in the testing of cochlear implant (CI) users. However, variance in scores across lists could degrade the sensitivity and reliability of them to identify deficits in speech perception. This study examined the relationship between variability in performance among lists and the lexical characteristics of the words. Data are from 28 adult CI users. Each subject was tested on all 10 CNC word lists. Data were analyzed in terms of lexical characteristics, lexical frequency, neighborhood density, bi-, and tri-phonemic probabilities. To determine whether individual performance variability across lists can be reduced, the standard set of 10 phonetically balanced 50-word lists was redistributed into a new set of lists using two sampling strategies: (a) balancing with respect to word lexical frequency or (b) selecting words with equal probability. The mean performance on the CNC lists varied from 53.1% to 62.4% correct. The average difference between the highest and lowest scores within individuals across the lists was 20.9% (from 12% to 28%). Lexical frequency and bi-phonemic probabilities were correlated with word recognition performance. The range of scores was not significantly reduced for all individuals when responses were simulated with 1,000 sets of redistributed lists, using both types of sampling methods. These results indicate that resampling of words does not affect the test-retest reliability and diagnostic value of the CNC word test.


Assuntos
Implante Coclear/instrumentação , Implantes Cocleares , Sinais (Psicologia) , Música , Pessoas com Deficiência Auditiva/reabilitação , Percepção da Altura Sonora , Estimulação Acústica , Adulto , Idoso , Audiometria , Estimulação Elétrica , Feminino , Humanos , Percepção Sonora , Masculino , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Reconhecimento Psicológico
4.
J Assoc Res Otolaryngol ; 17(4): 371-82, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27101997

RESUMO

Cochlear implant (CI) users have poor temporal pitch perception, as revealed by two key outcomes of rate discrimination tests: (i) rate discrimination thresholds (RDTs) are typically larger than the corresponding frequency difference limen for pure tones in normal hearing listeners, and (ii) above a few hundred pulses per second (i.e. the "upper limit" of pitch), CI users cannot discriminate further increases in pulse rate. Both RDTs at low rates and the upper limit of pitch vary across listeners and across electrodes in a given listener. Here, we compare across-electrode and across-subject variation in these two measures with the variation in performance on another temporal processing task, gap detection, in order to explore the limitations of temporal processing in CI users. RDTs were obtained for 4-5 electrodes in each of 10 Advanced Bionics CI users using two interleaved adaptive tracks, corresponding to standard rates of 100 and 400 pps. Gap detection was measured using the adaptive procedure and stimuli described by Bierer et al. (JARO 16:273-284, 2015), and for the same electrodes and listeners as for the rate discrimination measures. Pitch ranking was also performed using a mid-point comparison technique. There was a marginal across-electrode correlation between gap detection and rate discrimination at 400 pps, but neither measure correlated with rate discrimination at 100 pps. Similarly, there was a highly significant across-subject correlation between gap detection and rate discrimination at 400, but not 100 pps, and these two correlations differed significantly from each other. Estimates of low-rate sensitivity and of the upper limit of pitch, obtained from the pitch ranking experiment, correlated well with rate discrimination for the 100- and 400-pps standards, respectively. The results are consistent with the upper limit of rate discrimination sharing a common basis with gap detection. There was no evidence that this limitation also applied to rate discrimination at lower rates.


Assuntos
Implantes Cocleares , Percepção da Altura Sonora , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade
5.
J Assoc Res Otolaryngol ; 17(3): 237-52, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26926152

RESUMO

Variability in speech perception scores among cochlear implant listeners may largely reflect the variable efficacy of implant electrodes to convey stimulus information to the auditory nerve. In the present study, three metrics were applied to assess the quality of the electrode-neuron interface of individual cochlear implant channels: the electrically evoked compound action potential (ECAP), the estimation of electrode position using computerized tomography (CT), and behavioral thresholds using focused stimulation. The primary motivation of this approach is to evaluate the ECAP as a site-specific measure of the electrode-neuron interface in the context of two peripheral factors that likely contribute to degraded perception: large electrode-to-modiolus distance and reduced neural density. Ten unilaterally implanted adults with Advanced Bionics HiRes90k devices participated. ECAPs were elicited with monopolar stimulation within a forward-masking paradigm to construct channel interaction functions (CIF), behavioral thresholds were obtained with quadrupolar (sQP) stimulation, and data from imaging provided estimates of electrode-to-modiolus distance and scalar location (scala tympani (ST), intermediate, or scala vestibuli (SV)) for each electrode. The width of the ECAP CIF was positively correlated with electrode-to-modiolus distance; both of these measures were also influenced by scalar position. The ECAP peak amplitude was negatively correlated with behavioral thresholds. Moreover, subjects with low behavioral thresholds and large ECAP amplitudes, averaged across electrodes, tended to have higher speech perception scores. These results suggest a potential clinical role for the ECAP in the objective assessment of individual cochlear implant channels, with the potential to improve speech perception outcomes.


Assuntos
Limiar Auditivo/fisiologia , Implantes Cocleares , Percepção da Fala , Potenciais de Ação , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Humanos , Pessoa de Meia-Idade , Neurônios , Tomografia Computadorizada por Raios X
6.
J Acoust Soc Am ; 140(6): 4404, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28039993

RESUMO

Suboptimal interfaces between cochlear implant (CI) electrodes and auditory neurons result in a loss or distortion of spectral information in specific frequency regions, which likely decreases CI users' speech identification performance. This study exploited speech acoustics to model regions of distorted CI frequency transmission to determine the perceptual consequences of suboptimal electrode-neuron interfaces. Normal hearing adults identified naturally spoken vowels and consonants after spectral information was manipulated through a noiseband vocoder: either (1) low-, middle-, or high-frequency regions of information were removed by zeroing the corresponding channel outputs, or (2) the same regions were distorted by splitting filter outputs to neighboring filters. These conditions simulated the detrimental effects of suboptimal CI electrode-neuron interfaces on spectral transmission. Vowel and consonant confusion patterns were analyzed with sequential information transmission, perceptual distance, and perceptual vowel space analyses. Results indicated that both types of spectral manipulation were equally destructive. Loss or distortion of frequency information produced similar effects on phoneme identification performance and confusion patterns. Consonant error patterns were consistently based on place of articulation. Vowel confusions showed that perceptions gravitated away from the degraded frequency region in a predictable manner, indicating that vowels can probe frequency-specific regions of spectral degradations.


Assuntos
Implantes Cocleares , Adulto , Cóclea , Implante Coclear , Feminino , Humanos , Masculino , Neurônios , Fonética , Percepção da Fala , Adulto Jovem
7.
Trends Hear ; 192015 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-25656797

RESUMO

A rapid threshold measurement procedure, based on Bekesy tracking, is proposed and evaluated for use with cochlear implants (CIs). Fifteen postlingually deafened adult CI users participated. Absolute thresholds for 200-ms trains of biphasic pulses were measured using the new tracking procedure and were compared with thresholds obtained with a traditional forced-choice adaptive procedure under both monopolar and quadrupolar stimulation. Virtual spectral sweeps across the electrode array were implemented in the tracking procedure via current steering, which divides the current between two adjacent electrodes and varies the proportion of current directed to each electrode. Overall, no systematic differences were found between threshold estimates with the new channel sweep procedure and estimates using the adaptive forced-choice procedure. Test-retest reliability for the thresholds from the sweep procedure was somewhat poorer than for thresholds from the forced-choice procedure. However, the new method was about 4 times faster for the same number of repetitions. Overall the reliability and speed of the new tracking procedure provides it with the potential to estimate thresholds in a clinical setting. Rapid methods for estimating thresholds could be of particular clinical importance in combination with focused stimulation techniques that result in larger threshold variations between electrodes.


Assuntos
Limiar Auditivo , Implante Coclear/instrumentação , Implantes Cocleares , Surdez/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Psicoacústica , Estimulação Acústica , Adulto , Idoso , Idoso de 80 Anos ou mais , Surdez/diagnóstico , Surdez/psicologia , Estimulação Elétrica , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Detecção de Sinal Psicológico , Processamento de Sinais Assistido por Computador , Fatores de Tempo
8.
J Assoc Res Otolaryngol ; 16(2): 273-84, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25644786

RESUMO

Cochlear implant (CI) users usually exhibit marked across-electrode differences in detection thresholds with "focused" modes of stimulation, such as partial-tripolar (pTP) mode. This may reflect differences either in local neural survival or in the distance of the electrodes from the modiolus. To shed light on these two explanations, we compared stimulus-detection thresholds and gap-detection thresholds (GDTs) at comfortably loud levels for at least four electrodes in each of ten Advanced Bionics CI users, using 1031-pps pulse trains. The electrodes selected for each user had a wide range of stimulus-detection thresholds in pTP mode. We also measured across-electrode variations in both stimulus-detection and gap-detection tasks in monopolar (MP) mode. Both stimulus-detection and gap-detection thresholds correlated across modes. However, there was no significant correlation between stimulus-detection and gap-detection thresholds in either mode. Hence, gap-detection thresholds likely tap a source of across-electrode variation additional to, or different from, that revealed by stimulus-detection thresholds. Stimulus-detection thresholds were significantly lower for apical than for basal electrodes in both modes; this was only true for gap detection in pTP mode. Finally, although the across-electrode standard deviation in stimulus-detection thresholds was greater in pTP than in MP mode, the reliability of these differences--assessed by dividing the across-electrode standard deviation by the standard deviation across adaptive runs for each electrode--was similar for the two modes; this metric was also similar across modes for gap detection. Hence across-electrode differences can be revealed using clinically available MP stimulation, with a reliability comparable to that observed with focused stimulation.


Assuntos
Limiar Auditivo , Implantes Cocleares , Eletrodos Implantados , Adulto , Idoso , Humanos , Pessoa de Meia-Idade
9.
Ear Hear ; 35(6): 641-51, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25036146

RESUMO

OBJECTIVE: The objective of this study was to examine how the level of current required for cochlear implant listeners to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels, a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. DESIGN: Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing-those with the highest, median, and lowest thresholds-for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various pTP fractions. RESULTS: For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest thresholds had the narrowest dynamic ranges (for σ ≥ 0.5) and steepest growth of loudness functions for all electrode configurations. CONCLUSIONS: Together with previous studies using focused stimulation, the results suggest that auditory responses to electrical stimuli at both threshold and suprathreshold current levels are not uniform across the electrode array of individual cochlear implant listeners. Specifically, the steeper growth of loudness and thus smaller dynamic ranges observed for high-threshold channels are consistent with a degraded electrode-neuron interface, which could stem from lower numbers of functioning auditory neurons or a relatively large distance between the neurons and electrodes. These findings may have potential implications for how stimulation levels are set during the clinical mapping procedure, particularly for speech-processing strategies that use focused electrical fields.


Assuntos
Limiar Auditivo/fisiologia , Implantes Cocleares , Surdez/reabilitação , Percepção Sonora/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Surdez/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Ear Hear ; 32(4): 436-44, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21178633

RESUMO

OBJECTIVES: The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. DESIGN: Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. RESULTS: Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial tripolar configurations. The Wave V amplitude growth functions with increasing stimulus level showed the predicted effect of shallower growth for the partial tripolar than for the monopolar configuration, but this was observed only for the low-threshold channels. In contrast, high-threshold channels showed the opposite effect; steeper growth functions were seen for the partial tripolar configuration. CONCLUSIONS: These results suggest that behavioral thresholds or EABRs measured with a restricted stimulus can be used to identify potentially impaired cochlear implant channels. Channels having high thresholds and steep growth functions would likely not activate the appropriate spatially restricted region of the cochlea, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.


Assuntos
Vias Auditivas/fisiologia , Implante Coclear/métodos , Implantes Cocleares , Surdez/terapia , Eletrodos Implantados , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Estimulação Acústica , Adulto , Idoso , Artefatos , Vias Auditivas/citologia , Limiar Auditivo/fisiologia , Mapeamento Encefálico , Surdez/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurônios/fisiologia
11.
Trends Amplif ; 14(2): 84-95, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20724356

RESUMO

Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode-neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode-neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception.


Assuntos
Implantes Cocleares , Nervo Coclear/fisiopatologia , Correção de Deficiência Auditiva , Perda Auditiva/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Percepção da Fala , Estimulação Acústica , Limiar Auditivo , Sinais (Psicologia) , Perda Auditiva/fisiopatologia , Perda Auditiva/psicologia , Humanos , Desenho de Prótese , Psicoacústica , Processamento de Sinais Assistido por Computador , Inteligibilidade da Fala
12.
Hear Res ; 270(1-2): 134-42, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20727397

RESUMO

This study examines patterns of neural activity in response to single biphasic electrical pulses, presented alone or following a forward masking pulse train, delivered by a cochlear implant. Recordings were made along the tonotopic axis of the central nucleus of the inferior colliculus (ICC) in ketamine/xylazine anesthetized guinea pigs. The partial tripolar electrode configuration was used, which provided a systematic way to vary the tonotopic extent of ICC activation between monopolar (broad) and tripolar (narrow) extremes while maintaining the same peak of activation. The forward masking paradigm consisted of a 200 ms masker pulse train (1017 pulses per second) followed 10 ms later by a single-pulse probe stimulus; the current fraction of the probe was set to 0 (monopolar), 1 (tripolar), or 0.5 (hybrid), and the fraction of the masker was fixed at 0.5. Forward masking tuning profiles were derived from the amount of masking current required to just suppress the activity produced by a fixed-level probe. These profiles were sharper for more focused probe configurations, approximating the pattern of neural activity elicited by single (non-masked) pulses. The result helps to bridge the gap between previous findings in animals and recent psychophysical data.


Assuntos
Vias Auditivas/fisiologia , Percepção Auditiva , Implantes Cocleares , Colículos Inferiores/fisiologia , Mascaramento Perceptivo , Estimulação Acústica , Animais , Limiar Auditivo , Estimulação Elétrica , Cobaias , Fatores de Tempo
13.
Hear Res ; 268(1-2): 93-104, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20580801

RESUMO

The partial tripolar electrode configuration is a relatively novel stimulation strategy that can generate more spatially focused electric fields than the commonly used monopolar configuration. Focused stimulation strategies should improve spectral resolution in cochlear implant users, but may also be more sensitive to local irregularities in the electrode-neuron interface. In this study, we develop a practical computer model of cochlear implant stimulation that can simulate neural activation in a simplified cochlear geometry and we relate the resulting patterns of neural activity to basic psychophysical measures. We examine how two types of local irregularities in the electrode-neuron interface, variations in spiral ganglion nerve density and electrode position within the scala tympani, affect the simulated neural activation patterns and how these patterns change with electrode configuration. The model shows that higher partial tripolar fractions activate more spatially restricted populations of neurons at all current levels and require higher current levels to excite a given number of neurons. We find that threshold levels are more sensitive at high partial tripolar fractions to both types of irregularities, but these effects are not independent. In particular, at close electrode-neuron distances, activation is typically more spatially localized which leads to a greater influence of neural dead regions.


Assuntos
Implantes Cocleares , Nervo Coclear/patologia , Simulação por Computador , Modelos Neurológicos , Rampa do Tímpano/inervação , Gânglio Espiral da Cóclea/patologia , Sobrevivência Celular , Estimulação Elétrica , Humanos , Análise Numérica Assistida por Computador , Desenho de Prótese , Psicoacústica , Limiar Sensorial
14.
Ear Hear ; 31(2): 247-58, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20090533

RESUMO

OBJECTIVE: The goal of this study was to evaluate the ability of a threshold measure, made with a restricted electrode configuration, to identify channels exhibiting relatively poor spatial selectivity. With a restricted electrode configuration, channel-to-channel variability in threshold may reflect variations in the interface between the electrodes and auditory neurons (i.e., nerve survival, electrode placement, and tissue impedance). These variations in the electrode-neuron interface should also be reflected in psychophysical tuning curve (PTC) measurements. Specifically, it is hypothesized that high single-channel thresholds obtained with the spatially focused partial tripolar (pTP) electrode configuration are predictive of wide or tip-shifted PTCs. DESIGN: Data were collected from five cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp., Sylmar, CA). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the pTP configuration for which a fraction of current (sigma) from a center-active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. Forward-masked PTCs were obtained for channels with the highest, lowest, and median tripolar (sigma = 1 or 0.9) thresholds. The probe channel and level were fixed and presented with either the monopolar (sigma = 0) or a more focused pTP (sigma > or = 0.55) configuration. The masker channel and level were varied, whereas the configuration was fixed to sigma = 0.5. A standard, three-interval, two-alternative forced choice procedure was used for thresholds and masked levels. RESULTS: Single-channel threshold and variability in threshold across channels systematically increased as the compensating current, sigma, increased and the presumed electrical field became more focused. Across subjects, channels with the highest single-channel thresholds, when measured with a narrow, pTP stimulus, had significantly broader PTCs than the lowest threshold channels. In two subjects, the tips of the tuning curves were shifted away from the probe channel. Tuning curves were also wider for the monopolar probes than with pTP probes for both the highest and lowest threshold channels. CONCLUSIONS: These results suggest that single-channel thresholds measured with a restricted stimulus can be used to identify cochlear implant channels with poor spatial selectivity. Channels having wide or tip-shifted tuning characteristics would likely not deliver the appropriate spectral information to the intended auditory neurons, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.


Assuntos
Limiar Auditivo , Implante Coclear , Implantes Cocleares/efeitos adversos , Perda Auditiva/patologia , Perda Auditiva/terapia , Psicoacústica , Estimulação Acústica , Adulto , Idoso , Mapeamento Encefálico , Estimulação Elétrica , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Música , Mascaramento Perceptivo , Percepção da Fala , Gânglio Espiral da Cóclea/patologia
15.
J Acoust Soc Am ; 121(3): 1642-53, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17407901

RESUMO

The efficacy of cochlear implants is limited by spatial and temporal interactions among channels. This study explores the spatially restricted tripolar electrode configuration and compares it to bipolar and monopolar stimulation. Measures of threshold and channel interaction were obtained from nine subjects implanted with the Clarion HiFocus-I electrode array. Stimuli were biphasic pulses delivered at 1020 pulses/s. Threshold increased from monopolar to bipolar to tripolar stimulation and was most variable across channels with the tripolar configuration. Channel interaction, quantified by the shift in threshold between single- and two-channel stimulation, occurred for all three configurations but was largest for the monopolar and simultaneous conditions. The threshold shifts with simultaneous tripolar stimulation were slightly smaller than with bipolar and were not as strongly affected by the timing of the two channel stimulation as was monopolar. The subjects' performances on clinical speech tests were correlated with channel-to-channel variability in tripolar threshold, such that greater variability was related to poorer performance. The data suggest that tripolar channels with high thresholds may reveal cochlear regions of low neuron survival or poor electrode placement.


Assuntos
Percepção Auditiva/fisiologia , Implantes Cocleares , Acústica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Limiar Auditivo/fisiologia , Morte Celular , Cóclea/patologia , Cóclea/cirurgia , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurônios/patologia
16.
Curr Opin Neurobiol ; 15(4): 488-93, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16009544

RESUMO

The cochlear implant arguably is the most successful neural prosthesis. Studies of the responses of the central auditory system to prosthetic electrical stimulation of the cochlea are revealing the success with which electrical stimulation of a deaf ear can mimic acoustic stimulation of a normal-hearing ear. Understanding of the physiology of central auditory structures can lead to improved restoration of hearing with cochlear implants. In turn, the cochlear implant can be exploited as an experimental tool for examining central hearing mechanisms isolated from the effects of cochlear mechanics and transduction.


Assuntos
Córtex Auditivo/fisiologia , Percepção Auditiva/fisiologia , Mapeamento Encefálico , Implantes Cocleares , Plasticidade Neuronal/fisiologia , Estimulação Acústica , Animais , Surdez/fisiopatologia , Surdez/terapia , Estimulação Elétrica , Humanos
17.
J Assoc Res Otolaryngol ; 5(3): 305-22, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15492888

RESUMO

The design of contemporary multichannel cochlear implants is predicated on the presumption that they activate multiple independent sectors of the auditory nerve array. The independence of these channels, however, is limited by the spread of activation from each intracochlear electrode across the auditory nerve array. In this study, we evaluated factors that influence intracochlear spread of activation using two types of intracochlear electrodes: (1) a clinical-type device consisting of a linear series of ring contacts positioned along a silicon elastomer carrier, and (2) a pair of visually placed (VP) ball electrodes that could be positioned independently relative to particular intracochlear structures, e.g., the spiral ganglion. Activation spread was estimated by recording multineuronal evoked activity along the cochleotopic axis of the central nucleus of the inferior colliculus (ICC). This activity was recorded using silicon-based single-shank, 16-site recording probes, which were fixed within the ICC at a depth defined by responses to acoustic tones. After deafening, electric stimuli consisting of single biphasic electric pulses were presented with each electrode type in various stimulation configurations (monopolar, bipolar, tripolar) and/or various electrode orientations (radial, off-radial, longitudinal). The results indicate that monopolar (MP) stimulation with either electrode type produced widepread excitation across the ICC. Bipolar (BP) stimulation with banded pairs of electrodes oriented longitudinally produced activation that was somewhat less broad than MP stimulation, and tripolar (TP) stimulation produced activation that was more restricted than MP or BP stimulation. Bipolar stimulation with radially oriented pairs of VP ball electrodes produced the most restricted activation. The activity patterns evoked by radial VP balls were comparable to those produced by pure tones in normal-hearing animals. Variations in distance between radially oriented VP balls had little effect on activation spread, although increases in interelectrode spacing tended to reduce thresholds. Bipolar stimulation with longitudinally oriented VP electrodes produced broad activation that tended to broaden as the separation between electrodes increased.


Assuntos
Implantes Cocleares , Surdez/fisiopatologia , Surdez/terapia , Colículos Inferiores/fisiologia , Estimulação Acústica , Animais , Vias Auditivas/fisiologia , Cóclea/cirurgia , Estimulação Elétrica , Eletrodos Implantados , Desenho de Equipamento , Cobaias
18.
J Assoc Res Otolaryngol ; 5(1): 32-48, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14564662

RESUMO

This study examined the interactions between electrical stimuli presented through two channels of a cochlear implant. Experiments were conducted in anesthetized guinea pigs. Multiunit spike activity recorded from the auditory cortex reflected the cumulative effects of electric field interactions in the cochlea as well as any neural interactions along the ascending auditory pathway. The cochlea was stimulated electrically through a 6-electrode intracochlear array. The stimulus on each channel was a single 80- micro s/phase biphasic pulse. Channel interactions were quantified as changes in the thresholds for elevation of cortical spike rates. Experimental parameters were interchannel temporal offset (0 to +/-2000 micro s), interelectrode cochlear spacing (1.5 or 2.25 mm), electrode configuration (monopolar, bipolar, or tripolar), and relative polarity between channels (same or inverted). In most conditions, presentation of a subthreshold pulse on one channel reduced the threshold for a pulse on a second channel. Threshold shifts were greatest for simultaneous pulses, but appreciable threshold reductions could persist for temporal offsets up to 640 micro s. Channel interactions varied strongly with electrode configuration: threshold shifts increased in magnitude in the order tripolar, bipolar, monopolar. Channel interactions were greater for closer electrode spacing. The results have implications for design of speech processors for cochlear implants.


Assuntos
Córtex Auditivo/fisiologia , Implantes Cocleares , Surdez/terapia , Animais , Percepção Auditiva/fisiologia , Limiar Auditivo/fisiologia , Desenho de Equipamento , Cobaias
19.
J Neurophysiol ; 87(1): 478-92, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11784764

RESUMO

This study examines patterns of auditory cortical activity elicited by single-pulse cochlear implant stimuli that vary in electrode configuration, cochlear place of stimulation, and stimulus level. Recordings were made from the primary auditory cortex (area A1) of ketamine-anesthetized guinea pigs. The spatiotemporal pattern of neural spike activity was measured simultaneously across 16 cortical locations spanning approximately 2-3 octaves of the tonotopic axis. Such a pattern, averaged over 40 presentations of any particular stimulus, was defined as the "cortical image" of that stimulus. Acutely deafened guinea pigs were implanted with a 6-electrode animal version of the 22-electrode Nucleus banded electrode array (Cochlear). Cochlear electrode configurations consisted of monopolar (MP), bipolar (BP + N) with N inactive electrodes between the active and return electrodes (0 < or = N < or = 4), tripolar (TP) with one active electrode and two flanking return electrodes, and common ground (CG) with one active electrode and as many as five return electrodes. Cortical images typically showed a focus of maximum spike probability and minimum latency. Spike probabilities tended to decrease, and latencies tended to increase, with increasing cortical distance from that focus. Cortical images of TP stimuli were the most spatially compact, followed by BP + N images, and then MP images, which were the broadest. Images of CG stimuli were rather variable across animals and stimulus channels. The locations of cortical images shifted systematically from caudal to rostral as the cochlear place of stimulation changed from basal to apical. At the most sensitive cortical site for each condition, the dynamic ranges over which spike rates increased with increased current level were restricted to about 1-2 dB, regardless of configuration. Dynamic ranges tended to increase with increasing cortical distance from the most sensitive site. Electrode configurations that produced compact cortical images (e.g., TP and BP + 0) showed the greatest range of thresholds within each cortical image and the largest dynamic range at cortical sites removed from the most sensitive site.


Assuntos
Córtex Auditivo/anatomia & histologia , Córtex Auditivo/fisiologia , Mapeamento Encefálico/métodos , Implantes Cocleares , Potenciais de Ação/fisiologia , Animais , Limiar Auditivo/fisiologia , Surdez/cirurgia , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Eletrodos Implantados , Cobaias , Percepção Sonora/fisiologia , Microeletrodos/normas , Tempo de Reação/fisiologia
20.
J Neurophysiol ; 87(1): 493-507, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11784765

RESUMO

This study quantified the accuracy with which populations of neurons in the auditory cortex can represent aspects of electrical cochlear stimuli presented through a cochlear implant. We tested the accuracy of coding of the place of stimulation (i.e., identification of the active stimulation channel) and of the stimulus current level. Physiological data came from the companion study, which recorded spike activity of neurons simultaneously from 16 sites along the tonotopic axis of the guinea pig's auditory cortex. In that study, cochlear electrical stimuli were presented to acutely deafened animals through a 6-electrode animal version of the 22-electrode Nucleus banded electrode array (Cochlear). Cochlear electrode configurations consisted of monopolar (MP), bipolar (BP + N) with N inactive electrodes between the active and return electrodes (0 < or = N < or = 3), tripolar (TP) with one active electrode and two flanking return electrodes, and common ground (CG) with one active electrode and as many as five return electrodes. In the present analysis, an artificial neural network was trained to recognize spatiotemporal patterns of cortical activity in response to single presentations of particular stimuli and, thereby, to identify those stimuli. The accuracy of pair-wise discrimination of stimulation channels or of current levels was represented by the discrimination index, d', where d' = 1 was taken as threshold. In many cases, the threshold for discrimination of place of cochlear stimulation was < 0.75 mm, and the threshold for discrimination of current levels was < 1 dB. Cochlear electrode configurations varied in the accuracy with which they signaled to the auditory cortex the place of cochlear stimulation. The BP + N and TP configurations provided considerably greater sensitivity to place of stimulation than did the MP configuration. The TP configuration maintained accurate signaling of place of stimulation up to the highest current levels, whereas sensitivity was degraded at high current levels in BP + N configurations. Electrode configurations also varied in the dynamic range over which they signaled stimulus current level. Dynamic ranges were widest for the BP + 0 configuration and narrowest for the TP configuration. That is, the configuration that showed the most accurate signaling of cochlear place of stimulation (TP) showed the most restricted dynamic range for signaling of current level. These results suggest that the choice of the optimal electrode configuration for use by human cochlear-prosthesis users would depend on the particular demands of the speech-processing strategy that is to be employed.


Assuntos
Córtex Auditivo/fisiologia , Implantes Cocleares , Processamento de Sinais Assistido por Computador , Potenciais de Ação/fisiologia , Animais , Limiar Auditivo/fisiologia , Mapeamento Encefálico/métodos , Cóclea/fisiologia , Surdez/cirurgia , Estimulação Elétrica/métodos , Cobaias , Percepção Sonora/fisiologia , Redes Neurais de Computação , Tempo de Reação/fisiologia , Distribuições Estatísticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...