1.
J Vis Exp ; (173)2021 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-34369934

RESUMO

Gas reactions studied by in situ electron microscopy can be used to capture the real-time morphological and microchemical transformations of materials at length scales down to the atomic level. In situ closed-cell gas reaction (CCGR) studies performed using (scanning) transmission electron microscopy (STEM) can separate and identify localized dynamic reactions, which are extremely challenging to capture using other characterization techniques. For these experiments, we used a CCGR holder that utilizes microelectromechanical systems (MEMS)-based heating microchips (hereafter referred to as "E-chips"). The experimental protocol described here details the method for performing in situ gas reactions in dry and wet gases in an aberration-corrected STEM. This method finds relevance in many different materials systems, such as catalysis and high-temperature oxidation of structural materials at atmospheric pressure and in the presence of various gases with or without water vapor. Here, several sample preparation methods are described for various material form factors. During the reaction, mass spectra obtained with a residual gas analyzer (RGA) system with and without water vapor further validates gas exposure conditions during reactions. Integrating an RGA with an in situ CCGR-STEM system can, therefore, provide critical insight to correlate gas composition with the dynamic surface evolution of materials during reactions. In situ/operando studies using this approach allow for detailed investigation of the fundamental reaction mechanisms and kinetics that occur at specific environmental conditions (time, temperature, gas, pressure), in real-time, and at high spatial resolution.


Assuntos
Gases , Microscopia Eletrônica , Microscopia Eletrônica de Transmissão e Varredura , Oxirredução , Temperatura
2.
Microsc Microanal ; 26(2): 229-239, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32157982

RESUMO

Protocols for conducting in situ transmission electron microscopy (TEM) reactions using an environmental TEM with dry gases have been well established. However, many important reactions that are relevant to catalysis or high-temperature oxidation occur at atmospheric pressure and are influenced by the presence of water vapor. These experiments necessitate using a closed-cell gas reaction TEM holder. We have developed protocols for introducing and controlling water vapor concentrations in experimental gases from 2% at a full atmosphere to 100% at ~17 Torr, while measuring the gas composition using a residual gas analyzer (RGA) on the return side of the in situ gas reactor holder. Initially, as a model system, cube-shaped MgO crystals were used to help develop the protocols for handling the water vapor injection process and confirming that we could successfully inject water vapor into the gas cell. The interaction of water vapor with MgO triggered surface morphological and chemical changes as a result of the formation of Mg(OH)2, later validated with mass spectra obtained with our RGA system with and without water vapor. Integrating an RGA with an in situ scanning/TEM closed-cell gas reaction system can thus provide critical measurements correlating gas composition with dynamic surface restructuring of materials during reactions.

3.
Nanoscale Res Lett ; 9(1): 614, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25419195

RESUMO

By coupling techniques of simultaneous secondary (SE) and transmitted electron (TE) imaging at high resolution in a modern scanning transmission electron microscope (STEM), with the ability to heat specimens using a highly stable MEMS-based heating platform, we obtained synergistic information to clarify the behavior of catalysts during in situ thermal treatments. Au/iron oxide catalyst 'leached' to remove surface Au was heated to temperatures as high as 700°C. The Fe2O3 support particle structure tended to reduce to Fe3O4 and formed surface terraces; the formation, coalescence, and mobility of 1- to 2-nm particles on the terraces were characterized in SE, STEM-ADF, and TEM-BF modes. If combined with simultaneous nanoprobe spectroscopy, this approach will open the door to a new way of studying the kinetics of nano-scaled phenomena.

4.
Microsc Microanal ; 18(4): 656-66, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22835379

RESUMO

In prior research, specimen holders that employ a novel MEMS-based heating technology (Aduro™) provided by Protochips Inc. (Raleigh, NC, USA) have been shown to permit sub-Ångström imaging at elevated temperatures up to 1,000°C during in situ heating experiments in modern aberration-corrected electron microscopes. The Aduro heating devices permit precise control of temperature and have the unique feature of providing both heating and cooling rates of 106°C/s. In the present work, we describe the recent development of a new specimen holder that incorporates the Aduro heating device into a "closed-cell" configuration, designed to function within the narrow (2 mm) objective lens pole piece gap of an aberration-corrected JEOL 2200FS STEM/TEM, and capable of exposing specimens to gases at pressures up to 1 atm. We show the early results of tests of this specimen holder demonstrating imaging at elevated temperatures and at pressures up to a full atmosphere, while retaining the atomic resolution performance of the microscope in high-angle annular dark-field and bright-field imaging modes.

5.
Nano Lett ; 10(3): 1028-31, 2010 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-20146428

RESUMO

Scanning transmission electron microscope (STEM) images of gold nanoparticles at atmospheric pressure have been recorded through a 0.36 mm thick mixture of CO, O2, and He. This was accomplished using a reaction cell consisting of two electron-transparent silicon nitride membranes. Gold nanoparticles of a full width at half-maximum diameter of 1.0 nm were visible above the background noise, and the achieved edge resolution was 0.4 nm in accordance with calculations of the beam broadening.


Assuntos
Ouro/química , Microscopia Eletrônica de Transmissão e Varredura/métodos , Modelos Químicos , Nanopartículas/química , Nanopartículas/ultraestrutura , Pressão Atmosférica , Simulação por Computador
6.
Microsc Res Tech ; 72(3): 208-15, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19165742

RESUMO

In recent years, an increasing number of laboratories have been applying in situ heating (and ultimately, gas reaction) techniques in electron microscopy studies of catalysts and other nanophase materials. With the advent of aberration-corrected electron microscopes that provide sub-Angström image resolution, it is of great interest to study the behavior of materials at elevated temperatures while maintaining the resolution capabilities of the microscope. In collaboration with Protochips Inc., our laboratory is developing an advanced capability for in situ heating experiments that overcomes a number of performance problems with standard heating stage technologies. The new heater device allows, for example, temperature cycling from room temperature to greater than 1000 degrees C in 1 ms (a heating rate of 1 million Centigrade degrees per second) and cooling at nearly the same rate. It also exhibits a return to stable operation (drift controlled by the microscope stage, not the heater) in a few seconds after large temperature excursions. With Protochips technology, we were able to demonstrate single atom imaging and the behavior of nanocrystals at high temperatures, using high-angle annular dark-field imaging in an aberration-corrected (S)TEM. The new capability has direct applicability for remote operation and (ultimately) for gas reaction experiments using a specially designed environmental cell.


Assuntos
Sistemas Microeletromecânicos/instrumentação , Microscopia Eletrônica/instrumentação , Nanopartículas/química , Nanopartículas/ultraestrutura , Semicondutores/instrumentação , Temperatura , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...