Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 9: 849113, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35571173

RESUMO

Background: Initial studies of stereotactic body radiation therapy (SBRT) for refractory ventricular tachycardia (VT) have demonstrated impressive efficacy. Follow-up analyses have found mixed results and the role of SBRT for refractory VT remains unclear. We performed palliative, cardiac radio ablation in patients with ventricular tachycardia refractory to ablation and medical management. Methods: Arrhythmogenic regions were targeted by combining computed tomography imaging with electrophysiologic mapping with collaboration from a radiation oncologist, electrophysiologist and cardiac imaging specialist. Patients were treated with a single fraction 25 Gy. Total durations of VT, the quantity of antitachycardia pacing (ATP) and shocks before and after treatment as recorded by implantable cardioverter-defibrillators (ICDs) were analyzed. Follow-up extended until most recent device interrogation unless transplant, death or repeat ablation occurred sooner. Results: Fourteen patients (age 50-78, four females) were treated and had an average of two prior ablations. Nine had ACC/AHA Stage D heart failure and three had left ventricular assist devices (LVAD). Two patients died shortly after SBRT, one received a prompt heart transplant and another had significant VT durations in the following months that were inaccurately recorded by their device. Ten of the 14 patients remained with adequate data post SBRT for analysis with an average follow-up duration of 216 days. Seven of those 10 patients had a decrease in VT post SBRT. Comparing the 90 days before treatment to cumulative follow-up, patients had a 59% reduction in VT, 39% reduction in ATP and a 60% reduction in shocks. Four patients received repeat ablation following SBRT. Pneumonitis was the only complication, occurring in four of the fourteen patients. Conclusion: SBRT may have value in advanced heart failure patients with refractory VT acutely but the utility over long-term follow-up appears modest. Prospective randomized data is needed to better clarify the role of SBRT in managing refractory VT.

2.
Am J Emerg Med ; 52: 132-136, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34922232

RESUMO

BACKGROUND: Hands-on defibrillation (HOD) could theoretically improve the efficacy of cardiopulmonary resuscitation (CPR) though a few mechanisms. Polyethylene drapes could potentially facilitate safe HOD, but questions remain about the effects of CPR on polyethylene's conductance and the magnitude of current looping through rescuers' arms in contact with patients. METHODS: This study measured the leakage current through 2 mil (0.002 in.) polyethylene through two different current pathways before and after 30 min of continuous compressions on a CPR mannequin. The two pathways analyzed were the standardized IEC (International Electrotechnical Commission) leakage current analysis and a setup analyzing a current pathway looping through a rescuer's arms and returning to the patient. First, ten measurements involving the two pathways were obtained on a single polyethylene drape. 30 min of continuous compressions were applied to the drape on a CPR mannequin after which the ten measurements were repeated. RESULTS: Twenty patients undergoing elective cardioversion for atrial fibrillation (18/20) or atrial flutter (2/20) at Emory University Hospital underwent analysis all receiving 200 J shocks (age 38-101, 35% female). Through the IEC measurement method the peak leakage current mean was 0.70 +/- 0.02 mA before compressions and 0.59 +/- 0.19 mA after compressions. Only three of the ten measurements assessing current passing through a rescuer's arms had detectable current and each was of low magnitude. All measurements were well below the maximum IEC recommendations of 3.5 mA RMS and 5.0 mA peak. CONCLUSIONS: Polyethylene may facilitate safe HOD even after long durations of compressions. Current looping through a rescuer's arms is likely of insignificant magnitude.


Assuntos
Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica/métodos , Massagem Cardíaca/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Traumatismos por Eletricidade/prevenção & controle , Feminino , Humanos , Masculino , Manequins , Pessoa de Meia-Idade , Polietileno/uso terapêutico
3.
Wounds ; 30(5): 114-119, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29521643

RESUMO

Outpatient-based sharp debridement is considered an important element for the care of a chronic ulcer. OBJECTIVE: The aim of this study is to evaluate the change in bacterial amounts with sharp debridement in a clinical setting. MATERIALS AND METHODS: Bacterial autofluorescence, quantitative cultures, semiquantitative cultures, and qualitative speciation were performed predebridement and postdebridement during a single clinic visit. RESULTS: Thirty-six wounds were included in the analysis. The mean patient age was 62 years (range, 27-83 years), and there were 13 (36.11%) women and 23 (63.89%) men with an average body mass index of 33.8 kg/m² (range, 16.7-55.9 kg/m²). Of the 36 patients, 24 (66.67%) had type 2 diabetes and 19 (52.78%) had a prior history of lower extremity amputation. Majority of the ulcers were diabetic neuropathic (27, 75%); the most common location was on the plantar aspect of the foot (14, 41.67%) with a mean ulcer duration of 10 months (range, 1-36), mean ulcer area of 6.3 ± 12.8 cm² (range, 0.18-62.06 cm²), and mean volume of 2.2 ± 4.4 cm³ (range, 0.05-9.66 cm³). There was no statistically significant difference in bacterial autofluorescence between the predebridement (4.15 ± 8.82) and the postdebridement (4.65 ± 9.48) images (P = .32). There was a statistically significant difference in quantitative culture results between the predebridement (6.7 x 104 ± 1.4 x 106 CFU/cm²) and the postdebridement (1.7 x 104 ± 3.1 x 106 CFU/cm²) cultures (P = .04), although this is not a log reduction. CONCLUSIONS: There is no statistically significant difference between the predebridement versus postdebridement semiquantitative culture results or a detectable pattern of change for the most common bacterial species encountered. These results suggest little impact of clinic-based sharp debridement on bacteria.


Assuntos
Desbridamento , Úlcera/microbiologia , Úlcera/terapia , Cicatrização/fisiologia , Infecção dos Ferimentos/microbiologia , Infecção dos Ferimentos/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Desbridamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Wounds ; 28(11): 379-386, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27589359

RESUMO

BACKGROUND: Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. METHODS: Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. RESULTS: High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P < 0.001). The 3DWM device yielded correlations of ρ = 0.990, 0.987, 0.996 with P < 0.001 for length, width, and area when compared to manual measurements. CONCLUSION: The 3DWM device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.


Assuntos
Processamento de Imagem Assistida por Computador , Fotogrametria , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/patologia , Progressão da Doença , Humanos , Reprodutibilidade dos Testes , Fenômenos Fisiológicos da Pele
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...