Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(20): 33753-33764, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37859148

RESUMO

Post-compression can effectively further improve the peak power of laser pulses by shortening the pulse duration. Which has been investigated in various ranges of energy and central wavelength. However, the spatial intensity profile of high-peak-power laser pulses is generally inhomogeneous due to pump lasers, imperfect optical components, and dust in the optical layout. In post-compression, the B-integral is proportional to intensity, and wavefront distortions are induced in the spectral broadening stage, leading to a decrease in focusing intensity. Moreover, the beam intensity may be strongly modulated and beam inhomogeneity will be intensified in this process, causing damage to optical components and limiting the achievement of high peak power enhancement. In this study, to address these challenges, the laser pulse is first smoothed by introducing spatial dispersion using prism pairs or asymmetric four-grating compressors, and then the smoothed pulse is used for post-compression. The simulation results indicate that this method can effectively remove hot spots from laser pulses and maintain high peak power enhancement in post-compression.

2.
Opt Express ; 31(4): 6938-6946, 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36823939

RESUMO

We experimentally demonstrated the 3D propagation of laser filament in air by an Fabry-Pérot (F-P) cavity assisted imaging within a single exposure. The F-P cavity was composed of two parallel mirrors with certain reflectivity and transmission at filament laser, so that the beam was reflected and refracted multiple times between the two mirrors. The cross-sectional intensity patterns at different longitudinal positions along filament within a single exposure of CCD (Charge-coupled Device) were recorded. When keeping the incident angle of the F-P cavity as a constant and reducing its spacing distance, a better longitudinally resolved evolution of cross-sectional filament intensity patterns was obtained. The intensity evolution along laser filament by the F-P cavity assisted imaging method was consistent with the filament fluorescence measurement from the side. As an application, the transition of laser propagation from linear to nonlinear was unveiled by the F-P cavity assisted 3D imaging.

3.
Rev Sci Instrum ; 93(10): 103301, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319346

RESUMO

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.


Assuntos
Lasers , Aceleradores de Partículas , Radiometria/métodos , Radiobiologia , Aceleração
4.
Sci Rep ; 12(1): 1484, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-35087083

RESUMO

Radiotherapy is the current standard of care for more than 50% of all cancer patients. Improvements in radiotherapy (RT) technology have increased tumor targeting and normal tissue sparing. Radiations at ultra-high dose rates required for FLASH-RT effects have sparked interest in potentially providing additional differential therapeutic benefits. We present a new experimental platform that is the first one to deliver petawatt laser-driven proton pulses of 2 MeV energy at 0.2 Hz repetition rate by means of a compact, tunable active plasma lens beamline to biological samples. Cell monolayers grown over a 10 mm diameter field were exposed to clinically relevant proton doses ranging from 7 to 35 Gy at ultra-high instantaneous dose rates of 107 Gy/s. Dose-dependent cell survival measurements of human normal and tumor cells exposed to LD protons showed significantly higher cell survival of normal-cells compared to tumor-cells for total doses of 7 Gy and higher, which was not observed to the same extent for X-ray reference irradiations at clinical dose rates. These findings provide preliminary evidence that compact LD proton sources enable a new and promising platform for investigating the physical, chemical and biological mechanisms underlying the FLASH effect.


Assuntos
Neoplasias/radioterapia , Terapia com Prótons/métodos , Radioterapia (Especialidade)/métodos , Radiobiologia/métodos , Linhagem Celular , Humanos , Lasers , Método de Monte Carlo , Radiobiologia/instrumentação , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Síncrotrons
5.
Rev Sci Instrum ; 91(6): 063303, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611048

RESUMO

The development from single shot basic laser plasma interaction research toward experiments in which repetition rated laser-driven ion sources can be applied requires technological improvements. For example, in the case of radio-biological experiments, irradiation duration and reproducible controlled conditions are important for performing studies with a large number of samples. We present important technological advancements of recent years at the ATLAS 300 laser in Garching near Munich since our last radiation biology experiment. Improvements range from target positioning over proton transport and diagnostics to specimen handling. Exemplarily, we show the current capabilities by performing an application oriented experiment employing the zebrafish embryo model as a living vertebrate organism for laser-driven proton irradiation. The size, intensity, and energy of the laser-driven proton bunches resulted in evaluable partial body changes in the small (<1 mm) embryos, confirming the feasibility of the experimental system. The outcomes of this first study show both the appropriateness of the current capabilities and the required improvements of our laser-driven proton source for in vivo biological experiments, in particular the need for accurate, spatially resolved single bunch dosimetry and image guidance.


Assuntos
Aceleração , Embrião não Mamífero/efeitos da radiação , Lasers , Prótons , Radiobiologia/métodos , Peixe-Zebra/embriologia , Animais , Estudos de Viabilidade
6.
Sci Rep ; 9(1): 6714, 2019 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-31040311

RESUMO

The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a refinement of the ionoacoustic approach. With its capability of completely monitoring a single, focused proton bunch with prompt readout and high repetition rate, I-BEAT is a promising approach to meet future requirements of experiments and applications in the field of laser-based ion acceleration. We demonstrate its functionality at two laser-driven ion sources for quantitative online determination of the kinetic energy distribution in the focus of single proton bunches.

7.
Sci Rep ; 9(1): 7697, 2019 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-31118430

RESUMO

Today's high-power laser systems are capable of reaching photon intensities up to 1022 W cm-2, generating plasmas when interacting with material. The high intensity and ultrashort laser pulse duration (fs) make direct observation of plasma dynamics a challenging task. In the field of laser-plasma physics and especially for the acceleration of ions, the spatio-temporal intensity distribution is one of the most critical aspects. We describe a novel method based on a single-shot (i.e. single laser pulse) chirped probing scheme, taking nine sequential frames at frame rates up to THz. This technique, to which we refer as temporally resolved intensity contouring (TRIC) enables single-shot measurement of laser-plasma dynamics. Using TRIC, we demonstrate the reconstruction of the complete spatio-temporal intensity distribution of a high-power laser pulse in the focal plane at full pulse energy with sub-picosecond resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...