Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ScientificWorldJournal ; 2014: 802605, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25309957

RESUMO

The seismic performance of RC columns could be significantly improved by continuous spiral reinforcement as a result of its adequate ductility and energy dissipation capacity. Due to post-earthquake brittle failure observations in beam-column connections, the seismic behaviour of such connections could greatly be improved by simultaneous application of this method in both beams and columns. In this study, a new proposed detail for beam to column connection introduced as "twisted opposing rectangular spiral" was experimentally and numerically investigated and its seismic performance was compared against normal rectangular spiral and conventional shear reinforcement systems. In this study, three full scale beam to column connections were first designed in conformance with Eurocode (EC2-04) for low ductility class connections and then tested by quasistatic cyclic loading recommended by ACI Building Code (ACI 318-02). Next, the experimental results were validated by numerical methods. Finally, the results revealed that the new proposed connection could improve the ultimate lateral resistance, ductility, and energy dissipation capacity.


Assuntos
Arquitetura/métodos , Materiais de Construção/análise , Desastres , Terremotos , Colapso Estrutural/prevenção & controle , Simulação por Computador , Materiais de Construção/economia , Análise Custo-Benefício , Desenho de Equipamento , Humanos , Teste de Materiais , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...