Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.237
Filtrar
1.
Br J Cancer ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38906969

RESUMO

BACKGROUND: Lipid droplet formation is a prominent histological feature in clear cell renal cell carcinoma (ccRCC), but the significance and mechanisms underlying lipid droplet accumulation remain unclear. METHODS: Expression and clinical significance of MT1G in ccRCC were analyzed by using TCGA data, GEO data and scRNASeq data. MT1G overexpression or knockdown ccRCC cell lines were constructed and in situ ccRCC model, lung metastasis assay, metabolomics and lipid droplets staining were performed to explore the role of MT1G on lipid droplet accumulation in ccRCC. RESULTS: Initially, we observed low MT1G expression in ccRCC tissues, whereas high MT1G expression correlated with advanced disease stage and poorer prognosis. Elevated MT1G expression promoted ccRCC growth and metastasis both in vitro and in vivo. Mechanistically, MT1G significantly suppressed acylcarnitine levels and downstream tricarboxylic acid (TCA) cycle activity, resulting in increased fatty acid and lipid accumulation without affecting cholesterol metabolism. Notably, MT1G inhibited H3K14 trimethylation (H3K14me3) modification. Under these conditions, MT1G-mediated H3K14me3 was recruited to the CPT1B promoter through direct interaction with specific promoter regions, leading to reduced CPT1B transcription and translation. CONCLUSIONS: Our study unveils a novel mechanism of lipid droplet accumulation in ccRCC, where MT1G inhibits CPT1B expression through modulation of H3K14 trimethylation, consequently enhancing lipid droplet accumulation and promoting ccRCC progression. Graphical abstract figure Schematic diagram illustrating MT1G/H3K14me3/CPT1B-mediated lipid droplet accumulation promoted ccRCC progression via FAO inhibition.

2.
Clin Oral Investig ; 28(7): 375, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38878120

RESUMO

OBJECTIVE: To investigate the impact of mineralized dentin matrix (MDM) on the prognosis on bone regeneration and migration of retained roots after coronectomy. MATERIALS AND METHODS: Patients were divided into three groups based on the type of bone graft after coronectomy: Group C (n = 20, collagen), Group T (n = 20, tricalcium phosphate (TCP) + collagen), and Group D (n = 20, MDM + collagen). CBCT scans, conducted immediately and 6 months after surgery, were analyzed using digital software. Primary outcomes, including changes in bone defect depth and retained root migration distance, were evaluated 6 months after surgery. RESULTS: After 6 months, both Groups D and T exhibited greater reduction of the bone defect and lesser retained root migration than Group C (p < 0.001). Group D had greater regenerated bone volume in the distal 2 mm (73 mm3 vs. 57 mm3, p = 0.011) and lesser root migration (2.18 mm vs. 2.96 mm, p < 0.001) than Group T. The proportion of completely bone embedded retained roots was also greater in Group D than in Group C (70.0% vs. 42.1%, p = 0.003). CONCLUSIONS: MDM is an appropriate graft material for improving bone defect healing and reducing retained root migration after coronectomy. CLINICAL RELEVANCE: MDM is an autogenous material prepared chairside, which can significantly improve bone healing and reduce the risk of retained root re-eruption. MDM holds promise as a routine bone substitute material after M3M coronectomy.


Assuntos
Regeneração Óssea , Fosfatos de Cálcio , Colágeno , Tomografia Computadorizada de Feixe Cônico , Dentina , Humanos , Masculino , Feminino , Fosfatos de Cálcio/uso terapêutico , Prognóstico , Pessoa de Meia-Idade , Colágeno/uso terapêutico , Regeneração Óssea/efeitos dos fármacos , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/cirurgia , Adulto , Coroa do Dente/cirurgia , Resultado do Tratamento , Transplante Ósseo/métodos , Substitutos Ósseos/uso terapêutico
3.
Medicine (Baltimore) ; 103(16): e37803, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640336

RESUMO

An increase in CD4+ T cells in the synovium is closely linked to the pathogenesis of rheumatoid arthritis (RA). We aimed to identify the possible causes of the elevated CD4+ T cell levels and to explore the factors influencing disease activity in RA. Fifty-five RA patients, including 28 with active RA (ARA), 27 with inactive RA, and 22 healthy controls, were recruited for this study. The proportion of CCR9+CD4+ T cells and the expression of chemokine receptor 9 (CCR9) on CD4+ T cells were analyzed by flow cytometry. Enzyme-linked immunosorbent assay and chemiluminescent immunoassay were used to evaluate interleukin (IL)-17A and IL-6 levels, respectively. The proportion of CCR9+CD4+ T cells and the expression of CCR9 on CD4+ T cells increased significantly in peripheral blood (PB) and synovial fluid (SF) in ARA compared to those in inactive RA. Furthermore, SF contained more CCR9+CD4+ T cells, IL-6, and IL-17A than PB in RA patients. Moreover, CD4+ T cells in the PB of patients with RA, especially ARA, expressed more CCR9 and secreted more IL-6 and IL-17A after activation. Here, we also demonstrated that both the percentage of CCR9+ cells in CD4+ T cells and the expression of CCR9 on circulating CD4+ T cells were positively correlated with erythrocyte sedimentation rate, hypersensitive C-reactive protein, rheumatoid factor, and anti-cyclic citrullinated peptide antibody. CCR9+CD4+ T cells are elevated in PB and SF, and are associated with disease activity in patients with RA.


Assuntos
Artrite Reumatoide , Linfócitos T CD4-Positivos , Humanos , Artrite Reumatoide/imunologia , Artrite Reumatoide/metabolismo , Artrite Reumatoide/patologia , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/metabolismo , Interleucina-17/metabolismo , Interleucina-6/metabolismo , Receptores de Quimiocinas/metabolismo , Líquido Sinovial
4.
Biol Psychol ; 188: 108789, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38556043

RESUMO

The retrieval of information from long-term memory is a fundamental cognitive ability, crucial for most aspects of successful human functioning. Whether and how long-term memory retrieval (LTMR) can be improved with training has clear societal importance but also theoretical value for furthering our understanding of underlying mechanisms. Here, we provide electrophysiological evidence for the plasticity of semantic LTMR. Thirty-five university students were randomly assigned to adaptive semantic LTMR training (using a Posner task) or to a non-adaptive version of the training. Before and after training they were assessed on measures of semantic LTMR, working memory, central executive function (interference control, switching), reading fluency, and fluid intelligence. Adaptive LTMR training (relative to non-adaptive training) led to significant improvements in semantic LTMR. The intervention group (in contrast to the control group) also showed a significant reduction in the mean amplitude of the N400 ERP component and 700-1000 ms measured during a semantic LTMR task, suggesting that changes in retrieval occurred at an early/automatic point and retrieval processing in semantic processing. Moreover, transfer effects were observed for switching, working memory and reading fluency, but not for interference control or fluid intelligence. These results point to the plasticity of semantic LTMR, and suggest that improvement in this ability can transfer to other domains for which LTMR is key.


Assuntos
Eletroencefalografia , Função Executiva , Memória de Longo Prazo , Leitura , Semântica , Humanos , Feminino , Masculino , Função Executiva/fisiologia , Adulto Jovem , Memória de Longo Prazo/fisiologia , Potenciais Evocados/fisiologia , Transferência de Experiência/fisiologia , Testes Neuropsicológicos , Memória de Curto Prazo/fisiologia , Rememoração Mental/fisiologia , Adulto , Inteligência/fisiologia , Adolescente
5.
J Dent Sci ; 19(1): 329-337, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303889

RESUMO

Background/purpose: This study was designed to explore upper airway aerodynamic characteristics in individuals diagnosed with obstructive sleep apnea (OSA) and to evaluate correlations between these characteristics and other anatomical upper airway findings in these patients. Materials and methods: This was a retrospective study of 40 OSA patients (22 male, 18 female) who were stratified into groups with mild, moderate, and severe disease based upon overnight polysomnographic (PSG) recording results. Newtom5G cone-beam CT scans (CBCT) were conducted for all patients, and the resultant images were used to reconstruct three-dimensional images of the upper airways which were used to calculate aerodynamic characteristics. Differences in these characteristics between groups were evaluated with one-way ANOVAs, while relationships between anatomical and aerodynamic characteristics were assessed through Pearson correlation analyses. Results: The aerodynamic of the upper airway has typical characteristic in severe group. There was a significant negative correlation in severe group between resistance during inspiration (Rin) and volume (V) (r = -0.693, P = 0.013), minimum axial area (MMA) (r = -0.685, P = 0.014), and lateral dimension (LAT) (r = -0.724, P = 0.008), resistance during expiration (Rex) and LAT (r = -0.923, P < 0.001). Conclusion: This study showed that airway resistance during inspiration and expiration are most closely associated with upper airway collapse in OSA patients, with repetitive collapse occurring during both of these breathing processes. LAT may be an important anatomical factor associated with OSA pathogenesis and treatment.

6.
Clin Oral Implants Res ; 35(4): 407-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38287504

RESUMO

OBJECTIVES: To study bone healing of two-wall bone defects after alveolar ridge preservation using mineralized dentin matrix. MATERIALS AND METHODS: After distal roots extraction of second and fourth premolars (P2, P4) on one lateral mandible in 12 beagles, two-wall bone defects (5 × 5 × 5 mm) were surgically created distally to the remaining mesial roots of P2 and P4. A total of 24 sites were randomly allocated to three groups (implant material- time of execution): mineralized dentin matrix (MDM)-3 m (MDM + collagen membrane; 3 months), MDM-6 m (MDM particles + collagen membrane; 6 months), and C-6 m (collagen membrane only; 6 months). Clinical, radiographic, digital, and histological examinations were performed 3 and 6 months after surgery. RESULTS: The bone healing in MDM groups were better compared to Control group (volume of bone regenerated in total: 25.12 mm3 vs. 13.30 mm3, p = .046; trabecular volume/total volume: 58.84% vs. 39.18%, p = .001; new bone formation rate: 44.13% vs. 31.88%, p = .047). Vertically, the radiological bone level of bone defect in MDM-6 m group was higher than that in C-6 m group (vertical height of bone defect: 1.55 mm vs. 2.74 mm, p = .018). Horizontally, no significant differences in buccolingual bone width were found between MDM and C groups at any time or at any level below the alveolar ridge. The percentages of remaining MDM were <1% in both MDM-3 m and MDM-6 m groups. CONCLUSIONS: MDM improved bone healing of two-wall bone defects and might be considered as a socket fill material used following tooth extraction.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Cães , Animais , Alvéolo Dental/cirurgia , Alvéolo Dental/patologia , Processo Alveolar/cirurgia , Processo Alveolar/patologia , Colágeno , Extração Dentária , Dentina , Perda do Osso Alveolar/prevenção & controle , Perda do Osso Alveolar/cirurgia , Perda do Osso Alveolar/patologia
7.
Clin Oral Implants Res ; 35(4): 386-395, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38286766

RESUMO

OBJECTIVES: To assess the efficacy of dynamic computer-aided surgery (dCAS) in replacing a single missing posterior tooth, we compare outcomes when using registration-and-fixation devices positioned anterior or posterior to the surgical site. Registration is performed on either the anterior or opposite posterior teeth. METHODS: Forty individuals needing posterior single-tooth implant placement were randomly assigned to anterior or posterior registration. Nine parameters were analyzed to detect the deviations between planned and actual implant placement, using Mann-Whitney and t-tests for nonnormally and normally distributed data, respectively. RESULTS: The overall average angular deviation for this study was 2.08 ± 1.12°, with the respective average 3D platform and apex deviations of 0.77 ± 0.32 mm and 0.88 ± 0.32 mm. Angular deviation values for individuals in the anterior and posterior registration groups were 1.58°(IQR: 0.98°-2.38°) and 2.25°(IQR: 1.46°-3.43°), respectively (p = .165), with 3D platform deviations of 0.81 ± 0.29 mm and 0.74 ± 0.36 mm (p = .464), as well as 3D apex deviations of 0.89 ± 0.32 mm and 0.88 ± 0.33 mm (p = .986). No significant variations in absolute buccolingual (platform, p = .659; apex, p = .063), apicocoronal (platform, p = .671; apex, p = .649), or mesiodistal (platform, p = .134; apex, p = .355) deviations were observed at either analyzed levels. CONCLUSIONS: Both anterior and posterior registration approaches facilitate accurate dCAS-mediated implant placement for single missing posterior teeth. The device's placement (posterior-to or anterior-to the surgical site) did not affect the clinician's ability to achieve the planned implant location.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Dente , Humanos , Implantação Dentária Endóssea , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional
8.
J Dent ; 139: 104762, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37898432

RESUMO

OBJECTIVES: The study represents a preliminary evaluation of the accuracy of the dynamic navigation system (DNS) in coronectomy of the mandibular third molar (M3M). METHODS: The study included participants with an impacted M3M near the inferior alveolar canal. The coronectomy planes were designed before the surgery using cone-beam computed tomography (CBCT) imaging data and then loaded into the DNS program. Intraoperatively, the navigation system was used to guide the complete removal of the target crown. Postoperative CBCT imaging was used to assess any three-dimensional deviations of the actual postoperative from the planned preoperative section planes for each patient. RESULTS: A total of 12 patients (13 teeth) were included. The root mean square (RMS) deviation of the preoperatively designed plane from the actual postoperative surface was 0.69 ± 0.21 mm, with a maximum of 1.45 ± 0.83/-1.87 ± 0.63 mm deviation. The areas with distance deviations < 1 mm, 1-2 mm, and 2-3 mm were 71.97 ± 5.72 %, 22.96 ± 6.57 %, and 4.52 ± 2.28 %, respectively. Most patients showed extremely high convexity of the surface area located in the mesial region adjacent to the base of the extraction socket. There was no observable evidence of scratching of the buccolingual bone plate at the base of the extraction socket by the handpiece drill. CONCLUSIONS: These results provide preliminary support for the use of DNS-based techniques when extracting M3M using a buccal approach. This would improve the accuracy of coronectomy and reduce the potiential damage to the surrounding tissue. CLINICAL SIGNIFICANCE: DNS is effective for guiding coronectomy.


Assuntos
Dente Serotino , Traumatismos do Nervo Trigêmeo , Humanos , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Projetos Piloto , Extração Dentária , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Tomografia Computadorizada de Feixe Cônico , Computadores , Nervo Mandibular/diagnóstico por imagem
9.
J Dent Sci ; 18(4): 1747-1755, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799911

RESUMO

Background/purpose: The success of transcrestal sinus floor elevation (TSFE) is primarily reliant upon the experience of the surgeon owing to the limited operative visibility. To evaluate the accuracy associated with the use of a dynamic navigation system when conducting posterior maxilla implant surgery with TSFE. Materials and methods: Twenty-eight implants were placed in 28 patients requiring implantation in the posterior maxilla via a TSFE approach. The drills were used to access the planned position (within 1 mm of the bottom of the maxillary sinus floor) under dynamic navigation system. TSFE was then accomplished using osteotomes and a piezoelectric device. Lastly, the implant was inserted under the dynamic navigation. Three effective deviations between planned and actual implant placement were then measured including angular deviation (AD, degrees), entry point horizontal deviation (EPHD, mm), and apical point horizontal deviation (APHD, mm). Results: The AD, EPHD, and APHD between the planned and actual implant placement were 3.656 ± 1.665°, 1.073 ± 0.686 mm, and 1.086 ± 0.667 mm, respectively. Premolar site AD values were less than those for molar sites (P = 0.004). No significant differences in these outcomes were observed in different surgeons. Obvious sinus perforation was not detected by immediate postoperative cone beam computed tomography imaging. Conclusion: The accuracy associated with using a dynamic navigation system when conducting posterior maxilla implant surgery via a TSFE approach using piezoelectric devices was comparable. This technique thus achieved appropriate interventional precision and safety while decreasing the morbidity associated with the TSFE approach.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37814595

RESUMO

OBJECTIVES: To gauge the relative accuracy of the use of passive and active dynamic navigation systems when placing dental implants, and to determine how registration areas affect the performance of these systems. MATERIALS AND METHODS: Eighty implants were assigned to be placed into 40 total resin mandible models missing either the left or right first molars using either passive or active dynamic navigation system approaches. U-shaped tube registration devices were fixed in the edentulous site for 20 models each on the left or right side. Planned and actual implant positions were superimposed to assess procedural accuracy, and parameters including 3D entry deviation, angular deviation, and 3D apex deviation were evaluated with Mann-Whitney U tests and Wilcoxon signed-rank tests. RESULTS: Respective angular, entry, and apex deviation values of 1.563 ± 0.977°, 0.725 ± 0.268 mm, and 0.808 ± 0.284 mm were calculated for all included implants, with corresponding values of 1.388 ± 1.090°, 0.789 ± 0.285 mm, and 0.846 ± 0.301 mm in the active group and 1.739 ± 0.826°, 0.661 ± 0.236 mm, and 0.769 ± 0.264 mm in the passive group. Only angular deviation differed significantly among groups, and the registration area was not associated with any significant differences among groups. CONCLUSIONS: Passive and active dynamic navigation approaches can achieve comparable in vitro accuracy. Registration on one side of the missing single posterior tooth area in the mandible can complete single-tooth implantation on both sides of the posterior teeth, highlighting the promise of further clinical research focused on this topic.

11.
J Dent Sci ; 18(3): 1086-1093, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37404603

RESUMO

Background/purpose: Gingival tissue firmness cannot be objectively assessed or monitored in real-time in existing examinations. This study was designed to examine the potential utility of shear wave elastography (SWE) as a means of evaluating and monitoring gingival inflammation in an effort to assess the effects of initial periodontal therapy in patients with advanced periodontitis. Materials and methods: This pilot study included analyses of 66 sites in 6 advanced periodontitis patients. Patients underwent the SWE examination of the gingiva at the mid-labial and interdental papillae at baseline and at 2, 4, and 6 weeks following initial periodontal therapy. Measured periodontal parameters in these patients include Plaque index (PI), Gingival bleeding index (GBI), Probing depth (PD), and Clinical attachment loss (CAL). Results: Respective baseline SWE values at the mid-labial gingiva and interdental papilla 25.68 ± 6.82 kPa and 26.78 ± 6.20 kPa, with no significant differences between these two measures. A significant negative correlation between SWE and both PI (r = -0.350, P = 0.004) and GBI (r = -0.287, P = 0.020) was observed at baseline. Initial periodontal therapy contributed to significantly higher SWE values and tougher gingiva, particularly during the first two weeks. Postoperative changes in SWE were negatively correlated with SWE values at baseline (r = -0.710, P < 0.001). Conclusion: These results establish SWE as a sensitive noninvasive approach to quantitatively assessing changes in gingival elasticity in real-time.

12.
Clin Oral Implants Res ; 34(3): 221-232, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36691811

RESUMO

OBJECTIVES: To assess the relative accuracy of manual (U-shaped tube) and automatic (two-in-one) dynamic navigation registration techniques for implant surgery performed in posterior sites missing one tooth. MATERIALS AND METHODS: This study included 58 partially edentulous patients with 58 implants, including 31 and 27 in the manual and automatic groups. Deviations between the planned and actual implant placement were assessed. RESULTS: The angular deviation in the overall study cohort was 2.54 ± 1.21°, while the 3D deviations at the implant platform and apex were 0.90 ± 0.46 mm and 1.04 ± 0.47 mm, respectively. The respective angular deviations in the manual and automatic groups were 2.82 ± 1.17° and 2.21 ± 1.19° (p > .05), while platform deviations were 0.89 ± 0.48 mm and 0.91 ± 0.45 mm (p > .05), and apex deviations were 0.99 ± 0.48 mm and 1.11 ± 0.46 mm (p > .05). No significant differences in absolute buccolingual, mesiodistal, or apicocoronal deviations were detected between these groups at either level (p > .05) nor were did deviation distributions differ in the buccolingual, mesiodistal, or apicocoronal directions at the platform or apex levels (p > .05). CONCLUSIONS: Manual and automatic dynamic navigation registration techniques can achieve excellent accuracy when placing implants in posterior sites missing a single tooth. The two-in-one automatic registration technique can reduce the amount of time and intraoperative steps necessary to complete the registration process relative to the manual U-shaped tube registration technique. Further follow-up studies are necessary to expand on these results.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Dente , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional
13.
Chinese Journal of Urology ; (12): 180-186, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-994000

RESUMO

Objective:To compare the accuracy of different stone scoring systems for predicting the stone-free rate (SFR) after retrograde intrarenal surgery (RIRS).Methods:The clinical data of 227 patients with lithiasis undergoing RIRS from June 2017 to December 2020 in Affiliated Benq Hospital of Nanjing Medical University and Qingdao Fuwai Hospital were retrospectively analyzed. There were 152 males and 75 females. The average age was (53.0±10.4) years old. The average body mass index was (26.9±2.1)kg/m 2. The maximum diameter of the stone was (22.7±12.8)mm. The stone is located in left side in 133 cases and in right side in 94 cases. The stones of 44 cases were located in upper ureter, upper calyceal or renal pelvis, that of 23 cases were in medium calyceal, 157 cases in lower calyceal, and 3 cases in calyceal diverticulum.The average CT value of stone was (778.3±350.4)HU. American Society of Anesthesiology (ASA)scores: 86 cases of grade Ⅰ, 129 cases of grade Ⅱ, 12 cases of grade Ⅲ. Preoperative non-contrast CT was conducted and three-dimensional data were constructed. A single observer reviewed and entered the modified S.T.O.N.E., RUSS, modified S-ReSC, R. I.R.S., SHA.LIN, Ito nomogram, S. O.L.V.E., stone free index (SFI) scores. Logistic analysis were performed between every score and SFR. Receiver operating characteristic (ROC) curve was drawn to detect sensitivity and specificity of every score in predicting the SFR. The predictive accuracies of all scores were compared. Results:The SFR was 83.0%(189/227). There were statistically significant differences in modified S. T.O.N.E.(10.5±1.9 vs. 12.7±1.8), RUSS[1(0, 4) vs. 3(0, 6)], modified S-ReSC (8.2±5.6 vs. 11.8±6.0), R.I.R.S.(6.2±1.4 vs. 8.1±1.2), SHA.LIN (9.9±2.4 vs. 13.0±2.1), Ito nomogram (12.1±5.8 vs. 4.3±3.3), S. O.L.V.E. (6.8±1.6 vs. 8.7±1.2), SFI score (7.9±1.1 vs. 6.3±0.9) between the stone-free group and the stone remaining group ( P <0.05). Logistic regression revealed that modified S.T.O.N.E., RUSS, modified S-ReSC, R. I.R.S., SHA.LIN, Ito nomogram, S. O.L.V.E. and SFI score were significantly associated with SFR( P<0.05). There were no significant differences in the area under the curve (AUC) between the modified S. T.O.N.E., RUSS, R. I.R.S., SHA.LIN, Ito nomogram, S. O.L.V.E. and SFI score( P>0.05), but there were significant differences in the AUC between modified S-ReSC score and other score ( P<0.05). When the cutoff of SHA.LIN, SFI and R. I.R.S. score was determined as 10, 6 and 6 scores, the specificity of SHA.LIN, SFI and R. I.R.S. score was 94.7%, 92.6% and 89.5%, respectively. Conclusions:All score could predict the postoperative SFR of RIRS, while the SHA.LIN, SFI and R.I.R.S. score were more accurate than the other scores. The accuracy of the modified S-ReSC in predicting SFR after RIRS was slightly worse than other scores.

14.
Chinese Journal of Trauma ; (12): 38-46, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992571

RESUMO

Objective:To compare the clinical efficacy of minimally invasive anterior column screw placement assisted by orthopedic robot with anterior subcutaneous internal fixation (INFIX) in the treatment of unstable pelvic fracture.Methods:A retrospective cohort study was conducted to analyze 42 patients (25 males and 17 females; aged 16-68 years [(41.8±3.2)years] with unstable pelvic fracture admitted to Guizhou Provincial People′s Hospital from June 2018 to December 2021. Anterior column screw group ( n=22) received orthopedic robot-assisted anterior column screw fixation of anterior pelvic ring fracture, and INFIX group ( n=20) received subcutaneous INFIX of anterior pelvic ring fracture. Posterior pelvic ring injuries were treated with closed reduction and percutaneous sacroiliac screw internal fixation. The operation time of anterior pelvic ring fixation, intraoperative blood loss, intraoperative fluoroscopy times, off-bed activity time when the visual analogue scale (VAS) was<3 points during weight-bearing and fracture healing time were compared between the two groups. The quality of pelvic fracture reduction was assessed according to the Matta scoring criteria at 2 days after surgery. The Majeed functional score was used to assess the functional status at the last follow-up. Intraoperative and postoperative complications were observed in both groups. Results:All patients were followed up for 6-24 months [(11.3±0.5)months].The operation time of anterior pelvic ring fixation was (33.4±2.6)minutes in anterior column screw group and (30.2±2.9)minutes in INFIX group ( P>0.05). The intraoperative blood loss was (15.9±3.1)ml in anterior column screw group and (41.4±6.2)ml in INFIX group ( P<0.01). The intraoperative fluoroscopy times were 12.2±2.4 in anterior column screw group and 14.7±2.5 in INFIX group ( P>0.05). The off-bed activity time was (3.2±0.4) weeks in anterior column screw group and (6.6±1.2)weeks in INFIX group ( P<0.01). The fracture healing time was (12.7±1.4)weeks in anterior column screw group and (16.2±1.9) weeks in INFIX group ( P<0.01). According to Matta scoring criteria, the excellent and good rate of posterior pelvic ring reduction quality was 100% in both groups, while the excellent and good rate of the quality of anterior pelvic ring reduction was 100% (excellent in 16 patients and good in 6) in anterior column screw group compared with 90.0% (excellent in 11 patients, good in 7, and fair in 2) in INFIX group ( P<0.05). During the final follow-up, the excellent and good rate of Majeed functional score was 90.9% (excellent in 16 patients, good in 4 and fair in 2) in anterior column screw group, significantly different from 80.0% (excellent in 10 patients, good in 6 and fair in 4) in INFIX group ( P<0.05). During the operation, no important tissue injuries such as blood vessels, nerves or spermatic cord occurred in either group. In anterior column screw group, no postoperative complications such as infection, spermatic cord injury or implant breakage occurred; in INFIX group, there were 2 patients with incision fat liquefaction, 4 with lateral femoral cutaneous nerve symptoms and 1 with heterotopic ossification, without the occurrence of implant breakage. Conclusion:Compared with anterior subcutaneous INFIX, orthopedic robot-assisted anterior column screw internal fixation for the treatment of unstable pelvic fracture has advantages of less bleeding, earlier tambulation, faster fracture healing, better fracture reduction quality, more satisfied postoperative functional recovery, and fewer complications.

15.
Clinical Medicine of China ; (12): 75-80, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992469

RESUMO

Heart rate variability is one of the methods to evaluate cardiac autonomic nervous function. It is widely used because of its non-invasive, convenient, fast and other advantages. Various heart diseases, including cardiovascular disease, arrhythmia and myocardial disease, are closely related to autonomic dysfunction, so heart rate variability has also become one of the important indicators to predict the prognosis of heart disease. This article reviews the research status of heart rate variability and its application in heart disease.

16.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992120

RESUMO

Clinical high risk (CHR) is the prodrome stage of schizophrenia and the population with CHR show subtle clinical symptoms and abnormal brain structure and function. Specifically, the pathological changes in the brain were mainly manifested as reduced gray matter volume in the anterior cingulate gyrus and hippocampus, damaged white matter fibers in the corpus callosum, uncinate tract and arcuate tract, cerebellar atrophy, and abnormal resting-state brain network connection.This paper reviews the brain imaging features, their relationship with clinical symptoms, and their role in predicting clinical outcomes in individuals with CHR. In the future, we can combine artificial intelligence and neuroimaging techniques to find specific markers of brain structure and function in the CHR population to guide early clinical detection and intervention.

17.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-988732

RESUMO

【Subjects】 To investigate the clinical application value of myocardial contrast echocardiography (MCE) in selecting CTO-PCI patients. MethodsFrom February 2019 to March 2020, a total of 50 patients with chronic coronary artery occlusion were consecutively selected as the research subjects. MCE and two-dimensional speck-tracking echocardiography were completed before and 12 months after interventional therapy. The primary end point was major adverse cardiovascular events. Patients were divided into groups according to the preoperative myocardial perfusion level of MCE. The improvement of left ventricular function was evaluated by two-dimensional echocardiography and left ventricular global longitudinal strain. ResultsCompared with the abnormal perfusion group, the improvement of GLS in the normal perfusion group was greater (P=0.028). The wall motion score index (WMSI) of the abnormal perfusion group before PCI was higher than that of the normal perfusion group (P=0.002). WMSI in the abnormal perfusion group was higher than that in the normal perfusion group one year after PCI (P<0.001). The left ventricular GLS(P=0.008).WMSI(P=0.016) and left ventricular end-diastolic volume(P=0.032) in the normal perfusion group were improved compared with those before operation; The postoperative perfusion score of patients with abnormal perfusion was significantly improved ( P=0.032). ConclusionMCE has clinical application value in optimizing the selection of CTO-PCI patients. CTO patients with different myocardial perfusion types have different benefits after PCI.

18.
Chinese Critical Care Medicine ; (12): 1327-1330, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1010948

RESUMO

Bacterial infectious diseases are a class of diseases with specific pathogens. Current studies have shown the important application and signal transduction mechanism of exosomes in bacterial infectious diseases, but the studies are still limited. Therefore, the relationship between exosomes and bacterial infectious diseases should be further explored to provide new diagnosis and treatment ideas for clinicians. This paper reviews the mechanism and prospect of exosomes in bacterial infectious diseases caused by different pathogens. It summarizes the biological characteristics of exosomes. The mechanisms of bacterial infectious diseases, the primary pathways through which exosomes regulate various pathogens, and the modification of exosomes for anti-infection.


Assuntos
Humanos , Exossomos/metabolismo , Transdução de Sinais , Infecções Bacterianas/metabolismo , Doenças Transmissíveis
19.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-981058

RESUMO

OBJECTIVE@#Foreign studies have reported that coronary artery disease (CAD) patients with high baseline low-density lipoprotein cholesterol (LDL-C) may have a good prognosis, which is called the "cholesterol paradox". This study aimed to examine whether the "cholesterol paradox" also exists in the Chinese population.@*METHODS@#A total of 2,056 patients who underwent the first percutaneous coronary intervention (PCI) between 2014 and 2016 were enrolled in this retrospective cohort study and classified into two groups based on baseline LDL-C = 2.6 mmol/L (100 mg/dL). The outcomes of interest included major adverse cardiovascular events (MACE), all-cause mortality, recurrent nonfatal myocardial infarction, unexpected coronary revascularization, or any nonfatal stroke.@*RESULTS@#All-cause mortality occurred in 8 patients (0.7%) from the low-LDL-C group and 12 patients (2.4%) in the high-LDL-C group, with a significant difference between the two groups (adjusted hazard ratio: 4.030, 95% confidence interval: 1.088-14.934; P = 0.037). However, no significant differences existed for the risk of MACE or other secondary endpoints, such as unexpected revascularization, nor any nonfatal stroke in the two groups.@*CONCLUSION@#In this study, a high baseline LDL-C was not associated with a low risk of clinical outcomes in CAD patients undergoing first PCI, which suggested that the "cholesterol paradox" may be inapplicable to Chinese populations.


Assuntos
Humanos , LDL-Colesterol , Estudos Retrospectivos , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Colesterol , HDL-Colesterol , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Fatores de Risco
20.
International Eye Science ; (12): 567-572, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-965778

RESUMO

AIM: To investigate the short-term visual quality outcomes after femtosecond laser small incision lenticule extraction(SMILE)and evolution implantable collamer lens(EVO-ICL)implantation for the correction of moderate myopia.METHODS: Prospective control study. A total of 51 cases(51 eyes)with moderate myopia who underwent SMILE or EVO-ICL implantation surgery at Weifang Eye Hospital from April 2021 to February 2022 were selected. They were divided into SMILE group(30 patients, 30 eyes)and EVO-ICL group(21 patients, 21 eyes)according to the surgical methods. The changes of visual acuity [uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA)], diopter [spherical equivalent(SE)] and related parameters of optical quality analysis system(OQAS Ⅱ)were observed before surgery and at 1wk, 1 and 3mo after surgery, and the quality of vision(QoV)questionnaire was completed.RESULTS: At 3mo after surgery, the safety index(postoperative CDVA/preoperative CDVA)of SMILE gruop and EVO-ICL group were 1.20(1.00, 1.20)and 1.20(1.00, 1.38), respectively, the efficacy index(postoperative UDVA/preoperative CDVA)were 1.00(1.00, 1.20)and 1.00(1.00, 1.20), respectively, and the percentage of SE within ±0.50D was 87% and 100%, respectively. In SMILE group, the objective scattering index(OSI)was increased after surgery, while modulation transfer function cutoff frequency(MTF cutoff), contrast visual acuity(VA)100%, and VA20% at 1wk and 1mo after surgery, and Strehl ratio(SR)and VA9% at each time point after surgery were all decreased compared with those before surgery(all P&#x0026;#x003C;0.05). The OSI, MTF cutoff, SR and VA of EVO-ICL group showed no difference at each time point after surgery compared with those before surgery(all P&#x0026;#x003E;0.05). The most common visual symptoms after SMILE and EVO-ICL implantation were visual haze and halos, respectively.CONCLUSION: Both SMILE and EVO-ICL implantation have good safety, efficacy and predictability in the short term after the correction of moderate myopia. Both groups had visual symptoms after surgery, but the overall satisfaction of patients was high. Furthermore, EVO-ICL implantation has better objective visual quality performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...