Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 6(6): 406-14, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23127390

RESUMO

BACKGROUND: Computed tomography (CT) annular measurements are predictive of paravalvular regurgitation after transcatheter aortic valve replacement (TAVR) which is a predictor of mortality and morbidity. OBJECTIVES: To demonstrate the rationale and potential implications of new CT sizing recommendations for TAVR. METHODS: The CT sizing recommendations aim to ensure routine transcatheter heart valve (THV) oversizing of the aortic annular area [(THV external area/systolic annular area - 1) × 100; range, 1%-20%; target, 10%-15%]. Consecutive patients (n = 120) underwent CT before TAVR with balloon-expandable valves sized by transesophageal echocardiography (TEE). Retrospectively, the CT-recommended THV size was compared with the actual size implanted. RESULTS: Compared with TEE, application of the newly developed CT-based sizing recommendations would have led to implantation of a larger valve in 33.3% (40/120), no change in valve size in 55.8% (67/120), and a smaller valve in 10.8% (13/120). In patients when CT recommended a larger valve, the incidence of at least moderate paravalvular regurgitation was 25% (10/40) compared with 4.5% (3/67; P < 0.01) when both TEE and CT recommendations were in agreement. Using diastolic versus systolic CT measurements results in 20% of patients receiving smaller THVs. TEE sizing resulted in 33.3% (40/120) of valves being undersized (THV area < CT systolic annular area) with a mean annular oversizing of 9.4% ± 17.4% (range: -21.5% to 65.9%) without annular rupture. In contrast, the CT sizing recommendations results in mean annular oversizing of 13.9% ± 8.0% (range, 1.3%-29.8%). CONCLUSION: These CT sizing recommendations enable standardized moderate overexpansion of the aortic annulus. Clinical outcomes from these recommendations are being prospectively assessed in a multicenter trial.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cateteres Cardíacos , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Seleção de Pacientes , Cuidados Pré-Operatórios/métodos , Desenho de Prótese , Ajuste de Prótese , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...