Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Psychol ; 95(4): 769-80, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20604596

RESUMO

We examined the relationship between organizational identification and unethical pro-organizational behavior (UPB)-unethical behaviors conducted by employees to potentially benefit the organization. We predicted that organizational identification would be positively related to UPB and that positive reciprocity beliefs would moderate and strengthen this relationship. The results from 2 field studies support the interaction effect and show that individuals who strongly identify with their organization are more likely to engage in UPB when they hold strong positive reciprocity beliefs. Given the nature of reciprocity, our findings may suggest that highly identified employees who hold strong reciprocity beliefs may conduct UPB with an anticipation of a future reward from their organization. Theoretical and managerial implications of our results for understanding unethical behaviors are discussed.


Assuntos
Ética nos Negócios , Cultura Organizacional , Lealdade ao Trabalho , Adulto , Análise Fatorial , Feminino , Humanos , Masculino , Psicometria , Comportamento Social , Identificação Social , Inquéritos e Questionários , Local de Trabalho/psicologia , Adulto Jovem
3.
Clin Radiol ; 57(4): 263-7, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12014870

RESUMO

AIM: To demonstrate the magnetic resonance imaging (MRI) appearances of intact and ruptured Trilucent TM implants with imaging and surgical correlation. The appearances of the implant transponder artefact are also described MATERIALS AND METHODS: A retrospective review of the MRI findings in 34 patients with bilateral subpectoral Trilucent TM breast implants (Lipomatrix, Inc./Collagen Aesthetics International Inc., Neuchatel, Switzerland) was performed. Patients under implant surveillance and those with suspected implant rupture formed the study group. Imaging findings were correlated with surgical appearances. RESULTS: Surgical correlation was available in 53% of patients. Fifty per cent (18/36) of implants were intact at surgery, 50% (18/36) of implants were ruptured. Of the 18 ruptured implants, 17 were intracapsular ruptures and one an extracapsular rupture. The sensitivity of MRI for detection of intracapsular rupture in Trilucent TM breast implants was 82% specificity 76%, positive predictive value 78%, negative predictive value 81% and accuracy 79% in this study group. No case of implant rupture was obscured by the transponder artefact. Four implants were found to have 'pseudocapsules' at surgery (5.9%), the implants were intact with fluid present between the implant and capsule. Only one pseudocapsule was demonstrated on MRI. CONCLUSION: Magnetic resonance imaging is currently the most accurate technique for diagnosis of implant rupture in Trilucent TM breast implants. Transponder artefact does not appear to interfere with the assessment of implant rupture.


Assuntos
Implantes de Mama , Imageamento por Ressonância Magnética/métodos , Falha de Prótese , Adulto , Artefatos , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Óleo de Soja
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...