1.
Int J Cardiovasc Imaging ; 40(1): 15-25, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37815685

RESUMO

Bedside quantification of stroke volume (SV) and left ventricular ejection fraction (LVEF) is valuable in hemodynamically compromised patients. Miniaturized handheld ultrasound (HAND) devices are now available for clinical use. However, the performance level of HAND devices for quantified cardiac assessment is yet unknown. The aim of this study was to compare the validity of HAND measurements with standard echocardiography (SE) and three-dimensional echocardiography (3DE). Thirty-six patients were scanned with HAND, SE and 3DE. LVEF and SV quantification was done with automated software for the HAND, SE and 3DE dataset. The image quality of HAND and SE was evaluated by scoring segmental endocardial border delineation (2 = good, 1 = poor, 0 = invisible). LVEF and SV of HAND was evaluated against SE and 3DE using correlation and Bland-Altman analysis. The correlation, bias, and limits of agreement (LOA) between HAND and SE were 0.68 [0.46:0.83], 1.60% [- 2.18:5.38], and 8.84% [- 9.79:12.99] for LVEF, and 0.91 [0.84:0.96], 1.32 ml [- 0.36:4.01], 15.54 ml [- 18.70:21.35] for SV, respectively. Correlation, bias, and LOA between HAND and 3DE were 0.55 [0.6:0.74], - 0.56% [- 2.27:1.1], and 9.88% [- 13.29:12.17] for LVEF, and 0.79 [0.62:0.89], 6.78 ml [2.34:11.21], 12.14 ml [- 26.32:39.87] for SV, respectively. The image quality scores were 9.42 ± 2.0 for the apical four chamber views of the HAND dataset and 10.49 ± 1.7 for the SE dataset and (P < 0.001). Clinically acceptable accuracy, precision, and image quality was demonstrated for HAND measurements compared to SE. In comparison to 3DE, HAND showed a clinically acceptable accuracy and precision for LVEF quantification.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Humanos , Volume Sistólico , Ventrículos do Coração/diagnóstico por imagem , Valor Preditivo dos Testes , Ecocardiografia , Ecocardiografia Tridimensional/métodos , Reprodutibilidade dos Testes
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 6481-6484, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269731

RESUMO

Carotid - femoral pulse wave velocity is an established measure to assess cardiovascular risk and an interesting surrogate parameter towards non-invasive continuous blood pressure inference. Due to progress in sensing technologies for wearable wrist worn sensors, there are low cost sensor combinations of photo-plethysmography and high fidelity accelerometers available offering access to pulse information from larger arteries complemented by blood volume changes in the superficial tissue. In this work we compare pulse wave velocities derived from accelerometer and reflective photo-plethysmography signals placed at the carotid and femoral artery. We discuss the different underlying physiological processes for the two sensing principles and present experimental results obtained in a study with healthy subjects.


Assuntos
Acelerometria/métodos , Artérias Carótidas/fisiologia , Artéria Femoral/fisiologia , Pletismografia/métodos , Análise de Onda de Pulso/métodos , Adulto , Idoso , Doenças Cardiovasculares/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...