Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 114: 104168, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33218928

RESUMO

Changes in the elastic properties of brain tissue have been correlated with injury, cancers, and neurodegenerative diseases. However, discrepancies in the reported elastic moduli of brain tissue are persistent, and spatial inhomogeneities complicate the interpretation of macroscale measurements such as rheology. Here we introduce needle induced cavitation rheology (NICR) and volume-controlled cavity expansion (VCCE) as facile methods to measure the apparent Young's modulus E of minimally manipulated brain tissue, at specific tissue locations and with sub-millimeter spatial resolution. For different porcine brain regions and sections analyzed by NICR, we found E to be 3.7 ± 0.7 kPa and 4.8 ± 1.0 kPa for gray matter, and white matter, respectively. For different porcine brain regions and sections analyzed by VCCE, we found E was 0.76 ± 0.02 kPa for gray matter and 0.92 ± 0.01 kPa for white matter. Measurements from VCCE were more similar to those obtained from macroscale shear rheology (0.75 ± 0.06 kPa) and from instrumented microindentation of white matter (0.97 ± 0.40 kPa) and gray matter (0.86 ± 0.20 kPa). We attributed the higher stiffness reported from NICR to that method's assumption of a cavitation instability due to a neo-Hookean constitutive response, which does not capture the strain-stiffening behavior of brain tissue under large strains, and therefore did not provide appropriate measurements. We demonstrate via both analytical modeling of a spherical cavity and finite element modeling of a needle geometry, that this strain stiffening may prevent a cavitation instability. VCCE measurements take this stiffening behavior into account by employing an incompressible one-term Ogden model to find the nonlinear elastic properties of the tissue. Overall, VCCE afforded rapid and facile measurement of nonlinear mechanical properties of intact, healthy mammalian brain tissue, enabling quantitative comparison among brain tissue regions and also between species. Finally, accurate estimation of elastic properties for this strain stiffening tissue requires methods that include appropriate constitutive models of the brain tissue response, which here are represented by inclusion of the Ogden model in VCCE.


Assuntos
Encéfalo , Substância Branca , Animais , Módulo de Elasticidade , Substância Cinzenta , Reologia , Suínos
2.
PLoS One ; 13(10): e0204765, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30332434

RESUMO

Published data on the mechanical strength and elasticity of lung tissue is widely variable, primarily due to differences in how testing was conducted across individual studies. This makes it extremely difficult to find a benchmark modulus of lung tissue when designing synthetic extracellular matrices (ECMs). To address this issue, we tested tissues from various areas of the lung using multiple characterization techniques, including micro-indentation, small amplitude oscillatory shear (SAOS), uniaxial tension, and cavitation rheology. We report the sample preparation required and data obtainable across these unique but complimentary methods to quantify the modulus of lung tissue. We highlight cavitation rheology as a new method, which can measure the modulus of intact tissue with precise spatial control, and reports a modulus on the length scale of typical tissue heterogeneities. Shear rheology, uniaxial, and indentation testing require heavy sample manipulation and destruction; however, cavitation rheology can be performed in situ across nearly all areas of the lung with minimal preparation. The Young's modulus of bulk lung tissue using micro-indentation (1.4±0.4 kPa), SAOS (3.3±0.5 kPa), uniaxial testing (3.4±0.4 kPa), and cavitation rheology (6.1±1.6 kPa) were within the same order of magnitude, with higher values consistently reported from cavitation, likely due to our ability to keep the tissue intact. Although cavitation rheology does not capture the non-linear strains revealed by uniaxial testing and SAOS, it provides an opportunity to measure mechanical characteristics of lung tissue on a microscale level on intact tissues. Overall, our study demonstrates that each technique has independent benefits, and each technique revealed unique mechanical features of lung tissue that can contribute to a deeper understanding of lung tissue mechanics.


Assuntos
Pulmão/fisiologia , Animais , Fenômenos Biomecânicos , Módulo de Elasticidade , Feminino , Congelamento , Humanos , Técnicas In Vitro , Complacência Pulmonar/fisiologia , Masculino , Modelos Biológicos , Mecânica Respiratória/fisiologia , Reologia/métodos , Sus scrofa
3.
Carbohydr Polym ; 139: 131-8, 2016 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-26794956

RESUMO

Electrospinning hydrophilic nanofiber mats that deliver hydrophobic agents would enable the development of new therapeutic wound dressings. However, the correlation between precursor solution properties and nanofiber morphology for polymer solutions electrospun with or without hydrophobic oils has not yet been demonstrated. Here, cinnamaldehyde (CIN) and hydrocinnamic alcohol (H-CIN) were electrospun in chitosan (CS)/poly(ethylene oxide) (PEO) nanofiber mats as a function of CS molecular weight and degree of acetylation (DA). Viscosity stress sweeps determined how the oils affected solution viscosity and chain entanglement (Ce) concentration. Experimentally, the maximum polymer:oil mass ratio electrospun was 1:3 and 1:6 for CS/PEO:CIN and:H-CIN, respectively; a higher chitosan DA increased the incorporation of H-CIN only. The correlations determined for electrospinning plant-derived oils could potentially be applied to other hydrophobic molecules, thus broadening the delivery of therapeutics from electrospun nanofiber mats.


Assuntos
Quitosana/química , Nanofibras/química , Óleos Voláteis/química , Polietilenoglicóis/química , Acroleína/análogos & derivados , Acroleína/química , Álcoois/química , Interações Hidrofóbicas e Hidrofílicas , Peso Molecular , Reologia , Soluções , Tecnologia Farmacêutica , Viscosidade
4.
Oxf Med Case Reports ; 2015(4): 248-50, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26634137

RESUMO

Pelger-Huët anomaly (PHA) is a rare benign autosomal-dominant anomaly with an incidence of ∼1 in 6000. It does not cause neutrophilia, but it can cause a false increase in band forms. It should be differentiated from acquired or pseudo-Pelger-Huët anomaly (PPHA), which has similar morphology, however; it is associated with different pathological states like Myelodysplastic syndrome, as well as with certain infections and drugs. We report a case of a 67-year-old Caucasian gentleman with past medical history of rheumatoid arthritis, type II diabetes mellitus and hypothyroidism, who presented with 1 day history of fever (101°F) and night sweats. Medications include ibuprofen, methotrexate, hydroxychloroquine and levothyroxine. Patient denied any other symptoms. His work-up showed normal WBC count (8.6) and increase in bands (24%). The patient was admitted for further evaluation. During the next 2 days, the patient did not have any fever or any new symptoms. Peripheral blood smear was done as part of his work-up for bandemia, showed findings suggestive of PHA. Ibuprofen was discontinued. Follow-up few weeks later showed normal blood smear. Diagnosis of PPHA was made. The presented case showed that we should think of PHA\PPHA in any case with normal total WBC count and significant shift to the lift with no apparent explanation. Looking at smears directly under the microscopes is crucial to make diagnosis.

5.
J Mech Behav Biomed Mater ; 50: 299-307, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26189198

RESUMO

The current knowledge of bone marrow mechanics is limited to its viscous properties, neglecting the elastic contribution of the extracellular matrix. To get a more complete view of the mechanics of marrow, we characterized intact yellow porcine bone marrow using three different, but complementary techniques: rheology, indentation, and cavitation. Our analysis shows that bone marrow is elastic, and has a large amount of intra- and inter-sample heterogeneity, with an effective Young׳s modulus ranging from 0.25 to 24.7 kPa at physiological temperature. Each testing method was consistent across matched tissue samples, and each provided unique benefits depending on user needs. We recommend bulk rheology to capture the effects of temperature on tissue elasticity and moduli, indentation for quantifying local tissue heterogeneity, and cavitation rheology for mitigating destructive sample preparation. We anticipate the knowledge of bone marrow elastic properties for building in vitro models will elucidate mechanisms involved in disease progression and regenerative medicine.


Assuntos
Medula Óssea , Módulo de Elasticidade , Teste de Materiais , Animais , Fenômenos Biomecânicos , Reologia , Suínos
6.
Sultan Qaboos Univ Med J ; 15(2): e207-12, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26052453

RESUMO

Hyponatraemia is a common electrolyte disturbance, with moderate (serum sodium: 125-129 mmol/L) to severe (serum sodium: ≤125 mmol/L) forms of the disease occurring in 4-15% of hospitalised patients. While it is relatively common, determining the underlying cause of this condition can be challenging and may require extensive laboratory investigations. To this end, it is important to ascertain the efficacy of laboratory tests in determining the cause of hyponatraemia. Up to 10% of patients with hypothyroidism also have hyponatraemia. Routine evaluation of thyroid function is often advocated in cases of low serum sodium. A review and discussion of the available literature is presented here to examine this recommendation.

7.
Biomacromolecules ; 16(6): 1837-43, 2015 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-25932898

RESUMO

Biopolymer hydrogels are important materials for wound healing and cell culture applications. While current synthetic polymer hydrogels have excellent biocompatibility and are nontoxic, they typically function as a passive matrix that does not supply any additional bioactivity. Chitosan (CS) and pectin (Pec) are natural polymers with active properties that are desirable for wound healing. Unfortunately, the synthesis of CS/Pec materials have previously been limited by harsh acidic synthesis conditions, which further restricted their use in biomedical applications. In this study, a zero-acid hydrogel has been synthesized from a mixture of chitosan and pectin at biologically compatible conditions. For the first time, we demonstrated that salt could be used to suppress long-range electrostatic interactions to generate a thermoreversible biopolymer hydrogel that has temperature-sensitive gelation. Both the hydrogel and the solution phases are highly elastic, with a power law index of close to -1. When dried hydrogels were placed into phosphate buffered saline solution, they rapidly rehydrated and swelled to incorporate 2.7× their weight. As a proof of concept, we removed the salt from our CS/Pec hydrogels, thus, creating thick and easy to cast polyelectrolyte complex hydrogels, which proved to be compatible with human marrow-derived stem cells. We suggest that our development of an acid-free CS/Pec hydrogel system that has excellent exudate uptake, holds potential for wound healing bandages.


Assuntos
Materiais Biocompatíveis/química , Quitosana/química , Hidrogéis/química , Pectinas/química , Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/síntese química , Linhagem Celular , Elasticidade , Temperatura Alta , Humanos , Hidrogéis/efeitos adversos , Hidrogéis/síntese química , Concentração de Íons de Hidrogênio , Células-Tronco Mesenquimais/efeitos dos fármacos
8.
Langmuir ; 30(12): 3441-7, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24593694

RESUMO

Chronic wounds continue to be a global healthcare concern. Thus, the development of new nanoparticle-based therapies that treat multiple symptoms of these "non-healing" wounds without encouraging antibiotic resistance is imperative. One potential solution is to use chitosan, a naturally antimicrobial polycation, which can spontaneously form polyelectrolyte complexes when mixed with a polyanion in appropriate aqueous conditions. The requirement of at least two different polymers opens up the opportunity for us to form chitosan complexes with an additional functional polyanion. In this study, chitosan:pectin (CS:Pec) nanoparticles were synthesized using an aqueous spontaneous ionic gelation method. Systematically, a number of parameters, polymer concentration, addition order, mass ratio, and solution pH, were explored and their effect on nanoparticle formation was determined. The size and surface charge of the particles were characterized, as well as their morphology using transmission electron microscopy. The effect of polymer concentration and addition order on the nanoparticles was found to be similar to that of other chitosan:polyanion complexes. The mass ratio was tuned to create nanoparticles with a chitosan shell and a controllable positive zeta potential. The particles were stable in a pH range from 3.5 to 6.0 and lost stability after 14 days of storage in aqueous media. Due to the high positive surface charge of the particles, the innate properties of the polysaccharides used, and the harmless disassociation of the polyelectrolytes, we suggest that the development of these CS:Pec nanoparticles offers great promise as a chronic wound healing platform.


Assuntos
Quitosana/química , Nanopartículas/química , Pectinas/química , Polímeros/síntese química , Eletrólitos/síntese química , Eletrólitos/química , Concentração de Íons de Hidrogênio , Conformação Molecular , Tamanho da Partícula , Polímeros/química , Propriedades de Superfície
9.
Hemodial Int ; 17(4): 586-93, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23078106

RESUMO

Statins reduce inflammation in end-stage renal disease patients and improve endothelial function beyond cholesterol lowering. Despite this, statins do not improve the maturation rate, primary patency rate, and the cumulative survival of arteriovenous fistulas (AVFs). It is unknown if statins decrease the number of stenoses developing in AVFs or prolong the intervals between angioplasties needed to treat recurring stenoses. We conducted a retrospective chart review of our 265 active dialysis patients. The statin group was significantly more likely to be diabetic (64% vs. 43.6%) and treated with aspirin (64% vs. 40%) when compared to those not treated with statins (P=0.04 and 0.01). The mean time to first intervention (primary patency) was 16.5 months in statin users and 15.8 months in the nonstatin group (P=0.49) with standard deviations of ± 18.5 and 16.6 months, respectively. Statin use was not associated with a significant decrease in the number of stenoses diagnosed (P=0.28). The mean time between recurrent stenoses' angioplasties was 8.9 months in statin users and 7.3 months in the nonstatin patients (P=0.25). Aspirin users were more likely to have a decreased primary patency (rate ratio=1.65, P=0.03) compared with nonaspirin users. Patients who were prescribed aspirin developed 1.6 (P 0.01) times more stenoses than those not treated with aspirin. We report for the first time that statin therapy does not decrease the number of stenotic lesions developing in the AVF or prolong the interval between procedures required to treat recurrent stenoses.


Assuntos
Fístula Arteriovenosa/prevenção & controle , Fístula Arteriovenosa/cirurgia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Falência Renal Crônica/complicações , Fístula Arteriovenosa/fisiopatologia , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/sangue , Falência Renal Crônica/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular/efeitos dos fármacos
10.
J Mater Chem B ; 1(36): 4531-4541, 2013 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-32261196

RESUMO

Current strategies to treat chronic wounds offer limited relief to the 7.75 million patients who suffer from burns or chronic skin ulcers. Thus, as long as chronic wounds remain a global healthcare problem, the development of alternate treatments remain desperately needed. This review explores the recent strategies employed to tailor electrospun nanofiber mats towards accelerating the wound healing process. Porous nanofiber mats readily produced by the electrospinning process offer a promising solution to the management of wounds. The matrix chemistry, surface functionality, and mat degradation rate all can be fine-tuned to govern the interactions that occur at the materials-biology interface. In this review, first we briefly discuss the wound healing process and then highlight recent advances in drug release, biologics encapsulation, and antibacterial activity that have been demonstrated via electrospinning. While this versatile biomaterial has shown much progress, commercializing nanofiber mats that fully address the needs of an individual patient remains an ambitious challenge.

11.
Semin Dial ; 25(6): 700-2, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22428869

RESUMO

Vascular access dysfunction is a major contributor to end stage renal disease patient morbidity, and the cost of maintaining it is staggering. Any intervention able to improve the vascular access maturation rate and/or patency would be significant progress. Based on the anti-inflammatory and vascular beneficial effects demonstrated in non-end stage renal disease patients, we were hoping that statin use might provide the much needed improvement in the hemodialysis vascular access outcome. The reality proved disappointing. The statins failed to improve every aspect of hemodialysis vascular access studied. The present editorial discusses the current data regarding the effect of statins on vascular access and attempts to explain their lack of success.


Assuntos
Derivação Arteriovenosa Cirúrgica , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Falência Renal Crônica/terapia , Diálise Renal , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia
12.
Clin Chim Acta ; 350(1-2): 201-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15530479

RESUMO

BACKGROUND: 1,5-Anhydroglucitol (1,5-AG) is a glucose analogue, which is decreased in hyperglycemic individuals. We report the technical performance of an assay (GlycoMark) on a chemistry analyzer, evaluation of analyte stability and determination of reference intervals for 1,5-AG in a non-diabetic US population. METHODS: NCCLS protocols were followed to evaluate the reagent on a Hitachi 917 chemistry analyzer. RESULTS: Intra- and interassay imprecision ranged from 1.3% to 3.8% and 0.79% to 3.7%, respectively. The assay was linear to 110 microg/ml. Interference from triglyceride, hemoglobin and bilirubin was <10% to concentrations of 12.6 mmol/l, 12.1 and 911.4 micromol/l, respectively. Correlation coefficients between lot numbers on the Hitachi 917 and between analyses on the Hitachi 917 and the Hitachi 7170 analyzers were >0.99. The lowest limit of detection was 0.49 microg/ml (mean+/-2 S.D.). 1,5-AG was stable at 4 degrees C for 7 days, at 22 degrees C for 5 days, at -80 degrees C for 14 days and for three freeze-thaw cycles at -80 degrees C. The US reference intervals (nonparametric 2.5th-97.5th percentiles) were 10.2-33.8 microg/ml (males) and 5.9-31.8 microg/ml (females). CONCLUSIONS: The performance of the GlycoMark assay for the measurement of 1,5-AG was acceptable on the Hitachi 917 analyzer.


Assuntos
Autoanálise/instrumentação , Desoxiglucose/sangue , Diabetes Mellitus/sangue , Hiperglicemia/sangue , Adolescente , Bilirrubina/sangue , Biomarcadores , Glicemia/metabolismo , Etnicidade , Feminino , Hemoglobinas/metabolismo , Humanos , Imunoensaio , Masculino , Temperatura , Triglicerídeos/sangue
14.
J Mol Diagn ; 5(3): 191-4, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12876210

RESUMO

In myxoid/round cell liposarcoma, the t(12;16)(q13;p11) and its associated fusion transcript, FUS-CHOP, characterize greater than 95% of cases. The variant translocation t(12;22)(q13;q12) and associated EWS-CHOP fusion transcript are rare. A second non-random aberration observed in roughly 20% of Ewing's sarcomas, and to a lesser extent other select sarcomas, is the unbalanced 1;16 translocation. Recognition of this secondary aberration in the absence of an obvious primary karyotypic abnormality strongly suggests that the use of other genetic approaches will be informative in uncovering a clinically suspected primary anomaly. The following case illustrates the utility of molecular cytogenetic and reverse transcriptase-polymerase chain reaction techniques in diagnosing an ins(22;12)(q12;q13q14) and associated EWS-CHOP fusion transcript in a myxoid/round cell liposarcoma exhibiting a der(16)t(1;16)(q11;q11).


Assuntos
Cromossomos Humanos Par 12 , Cromossomos Humanos Par 16 , Cromossomos Humanos Par 1 , Cromossomos Humanos Par 22 , Lipossarcoma Mixoide/genética , Translocação Genética , Adulto , Proteínas Estimuladoras de Ligação a CCAAT/genética , Humanos , Cariotipagem , Masculino , Proteínas de Fusão Oncogênica/genética , Proteína EWS de Ligação a RNA/genética , Proteína FUS de Ligação a RNA/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fator de Transcrição CHOP
17.
Am J Clin Pathol ; 119(4): 516-21, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12710124

RESUMO

Detection of Chlamydia trachomatis and/or Neisseria gonorrhoeae infection in urine using molecular amplification assays has permitted institutions with limited medical facilities to offer testing for these sexually transmitted diseases (STDs). The Nebraska Public Health Laboratory (NPHL) investigated the validity of urine samples submitted for C trachomatis and/or N gonorrhoeae amplification after receiving a substantial number of clear specimens. Approximately 75% of all urine specimens submitted for STD testing to the NPHL were from correctional facilities. The falsification of urine specimens submitted for microbiology studies is not evaluated routinely, and this problem was previously undocumented. By using the criteria for specific gravity of 1.001 or less and a creatinine concentration of less than 5 mg/dL (442 mumol/L), approximately 8% of all specimens submitted during the study interval were determined to be inconsistent with urine. The microbiology laboratory should be aware of the possibility for specimen manipulation to identify facilities submitting falsified specimens, to initiate appropriate intervention, and to minimize false-negative reporting.


Assuntos
Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis/isolamento & purificação , Gonorreia/diagnóstico , Neisseria gonorrhoeae/isolamento & purificação , Vigilância da População/métodos , Infecções por Chlamydia/urina , Gonorreia/urina , Humanos , Programas de Rastreamento/métodos , Nebraska , Má Conduta Científica , Gravidade Específica , Manejo de Espécimes/métodos
18.
Cancer Genet Cytogenet ; 141(2): 164-8, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12606137

RESUMO

Cytogenetic analysis has improved our understanding of the histopathogenesis of many benign and malignant bone and soft tissue tumors, as well as served as an important diagnostic adjunct for these pathologic entities. Cytogenetic reports of benign cartilaginous tumors, however, are relatively few. This is unfortunate, as distinguishing benign and malignant cartilaginous neoplasms can often be difficult. In this study, the cytogenetic findings of two enchondromas, two periosteal chondromas, and one soft part chondroma and a review of the literature are reported. Abnormal diploid or near-diploid clones were detected in all specimens analyzed. Although a tumor-specific anomaly did not emerge from these studies, involvement of certain chromosomes/chromosomal regions appears recurrent.


Assuntos
Neoplasias Ósseas/genética , Condroma/genética , Aberrações Cromossômicas , Periósteo , Neoplasias de Tecidos Moles/genética , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...