The Academic Society ; 4(2): 131-143, Jun. 2020. ilustração, imagem, gráfico, tabela
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1103679

RESUMO

Abstract. In the face of the coronavirus pandemic (COVID-19), in hospital and emergency units, there is low availability of mechanical respirator for patients in need of this support, greatly improving the survival rate. In these situations, there is a need for simpler equipment, easy access, low cost, and fast manufacturing. In this study, a 3D prototype transport respirator was developed using as a model the Takaoka 600 Mini Respirator, national technology from the 1950s. The influence of adjustable parameters of the respirator was evaluated to understand it is functioning: maximum and minimum lung pressure; respirator intake pressure; respiratory rate; inspiratory and expiratory time according to the sensitivity of the mini respirator; and pressure and flow of O2 line intake. The increase in sensitivity led to an increase in maximum and minimum pulmonary pressure, decreased inspiratory and expiratory time, with margins of 1/1, 1/2, 1/3 inspiratory/expiratory time ratio (I/E ratio). The intake flow of O2 varied proportionally with the pressure of air intake into the respirator, with its increase leading to an increase in respiratory rate, without major influences on lung pressure and the I/E ratio. The O2 line intake pressure without major influences on lung pressure, showing and I/E ratio >1 in values below 3.5 kPa x 100. In conclusion, it was possible to obtain a pulmonary ventilator-dependent only on positive O2 flow, compact and effective for patient transport, and in cases of emergencies with control of maximum pressure and respiratory rate offered to the patient. Among the parameters evaluated for this respirator, an line pressure of O2 from 3.5 kPa x 100, sensitivity between 3 and 5, a flow of 5 to 15 L/min is recommended.


Assuntos
Ventiladores Mecânicos , Infecções por Coronavirus , Suporte Ventilatório Interativo , Unidades de Terapia Intensiva
2.
Arq Bras Cardiol ; 61(2): 93-7, 1993 Aug.
Artigo em Português | MEDLINE | ID: mdl-8297228

RESUMO

PURPOSE: To test the hypothesis of respiratory support and to study the consequent hemodynamic alterations, we performed pumpless A-V ECMO using a 1.2m2 polipropylene hollow fiber membrane oxygenator, specially adapted from conventional model utilized in routine cardiac surgery. METHODS: Two canine groups of six dogs each were studied. Group 1 had normal lungs and group 2 acute respiratory failure induced by 0.035ml/kg intravenous oleic acid. The dogs were anesthetized and maintained in apnea with curare. Heparin was given in a single dose of 400U/kg. Gasimetric and hemodynamic parameters were monitored each 30 minutes during a 3 hour period. Then the oxygenator was discontinued and after 15 minutes a final arterial blood gas sample was taken for analysis. RESULTS: Blood samples at 3 hours have shown a mean PaO2 of 260.6mmHg in group 1 and 114.4mmHg in group 2 and PaCO2 of 54.3 and 56.2mmHg, respectively. After the oxygenator was discontinued PaCO2 levels increased to 161.6 and 193.7mmHg, respectively. The hemodynamic parameters shown few alterations. CONCLUSION: In both groups pumpless A-V ECMO was able to maintain gasimetric parameters within acceptable patterns and compatible with life, with few hemodynamic alterations. However, an adequate mean arterial blood pressure is needed to provide flow through membrane oxygenator.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Animais , Cães , Ácidos Oleicos , Pressão Parcial , Insuficiência Respiratória/induzido quimicamente
6.
Rev. paul. med ; 99(3): 30-3, 1982.
Artigo em Português | LILACS | ID: lil-8134

RESUMO

E apresentado um dispositivo para realizacao de autotransfusao intra-operatoria, constituido por um recipiente de acrilico, descartavel e capaz de coletar, anticoagular e filtrar o sangue. A autotransfusao foi praticada em 12 casos, sendo 8 em cirurgia de emergencia e 4 em cirurgia seletiva. O dispositivo mostrou-se simples e de facil utilizacao, mas elevada frequencia de contaminacao em amostra de sangue aspirado indica a necessidade de aprimoramento na manipulacao do mesmo


Assuntos
Humanos , Cuidados Intraoperatórios , Transfusão de Sangue Autóloga
9.
Artigo em Português | LILACS | ID: lil-2772

RESUMO

Os autores apresentam um novo modelo de sonda para alimentacao enteral, inteiramente feito de silastic radiopaco e provido, na sua extremidade distal, de um pequeno balao contendo mercurio. Suas vantagens em relacao as sondas de alimentacao tradicionais sao: menor calibre, extraordinaria flexibilidade e biocompatibilidade e facilidade de migracao espontanea para o duodeno ou jejuno, quando desejada. Sua utilizacao em dez pacientes que dependiam de alimentacao enteral para manutencao ou melhora das suas condicoes nutritivas, revelou resposta satisfatoria ao tratamento, com ausencia de fenomenos irritativos e excelente tolerancia por parte dos enfermos propiciando uma infusao mais constante e mais segura da dieta


Assuntos
Nutrição Enteral , Intubação Gastrointestinal , Elastômeros de Silicone