Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Arch Intern Med ; 160(7): 1017-21, 2000 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-10761968

RESUMO

CONTEXT: Under routine hospital conditions handwashing compliance of health care workers including nurses, physicians, and others (eg, physical therapists and radiologic technicians) is unacceptably low. OBJECTIVES: To investigate the efficacy of an education/ feedback intervention and patient awareness program (cognitive approach) on handwashing compliance of health care workers; and to compare the acceptance of a new and increasingly accessible alcohol-based waterless hand disinfectant (technical approach) with the standard sink/soap combination. DESIGN: A 6-month, prospective, observational study. SETTING: One medical intensive care unit (ICU), 1 cardiac surgery ICU, and 1 general medical ward located in a 728-bed, tertiary care, teaching facility. PARTICIPANTS: Medical caregivers in each of the above settings. INTERVENTIONS: Implementation of an education/ feedback intervention program (6 in-service sessions per each ICU) and patient awareness program, followed by a new, increasingly accessible, alcohol-based, waterless hand antiseptic agent, initially available at a ratio of 1 dispenser for every 4 patients and subsequently 1 for each patient. MAIN OUTCOME MEASURE: Direct observation of hand-washing for 1575 potential opportunities monitored over 120 hours randomized for both time of day and bed locations. RESULTS: Baseline handwashing compliance before and after defined events was 9% and 22% for health care workers in the medical ICU and 3% and 13% for health care workers in the cardiac surgery ICU, respectively. After the education/feedback intervention program, handwashing compliance changed little (medical ICU, 14% [before] and 25% [after]; cardiac surgery ICU, 6% [before] and 13% [after]). Observations after introduction of the new, increasingly accessible, alcohol-based, waterless hand antiseptic revealed significantly higher handwashing rates (P<.05), and handwashing compliance improved as accessibility was enhanced-before 19% and after 41% with 1 dispenser per 4 beds; and before 23% and after 48% with 1 dispenser for each bed. CONCLUSIONS: Education/feedback intervention and patient awareness programs failed to improve handwashing compliance. However, introduction of easily accessible dispensers with an alcohol-based waterless handwashing antiseptic led to significantly higher handwashing rates among health care workers.


Assuntos
Anti-Infecciosos Locais , Etanol , Desinfecção das Mãos , Pessoal de Saúde/estatística & dados numéricos , Hospitais de Ensino/estatística & dados numéricos , Adulto , Unidades de Cuidados Coronarianos/estatística & dados numéricos , Educação Continuada , Feminino , Departamentos Hospitalares/estatística & dados numéricos , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Medicina Interna , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Virginia
3.
J Clin Microbiol ; 37(12): 3912-6, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10565906

RESUMO

To investigate the dissemination of vancomycin-resistant Enterococcus faecium (VREF) in a 728-bed tertiary-care hospital, all clinical VREF isolates recovered from June 1992 to June 1997 were typed by pulsed-field gel electrophoresis, and the transfer histories of the patients were documented. A total of 413 VREF isolates from urine (52%), wounds (16%), blood (11%), catheter tips (6%), and other sites (15%) were studied. VREF specimens mostly came from patients on wards (66%) but 34% came from patients in an intensive care unit. The number of VREF isolates progressively increased over time, with higher rates of isolation during the winter months and lower rates in the late summer months. Four distinct banding patterns were detected by pulsed-field gel electrophoresis among 316 samples (76%). Strain A (122 samples; 30%) appeared in June 1992 as the first VREF strain and was found until December 1994 throughout the entire hospital. Type B (92 samples; 22%) was initially detected in January 1994 and disappeared in November 1996. Strain C (10 samples; 2%) was limited to late 1996 and early 1997. Strain D (92 samples; 22%) showed two major peaks during March 1996 to August 1996 and January 1997 to February 1997. Unrelated strains (97 samples; 24%) appeared 1 year after the appearance of the first VREF isolate, and the numbers increased slightly over the years. Nosocomial acquisition (i.e., no known detection prior to admission and first isolation from cultures performed with samples retrieved >/=2 days after hospitalization) was found for 316 (91%) of 347 patients. Despite the implementation of Centers for Disease Control and Prevention guidelines, the proportion of related strains and high number of nosocomial cases of infection indicate a high transmission rate inside the hospital. The results imply an urgent need for stringent enforcement of more effective infection control measures.


Assuntos
Enterococcus faecium/classificação , Infecções por Bactérias Gram-Positivas/epidemiologia , Hospitais Urbanos , Resistência a Vancomicina , Antibacterianos/farmacologia , Técnicas de Tipagem Bacteriana , Infecções Comunitárias Adquiridas , Infecção Hospitalar , Eletroforese em Gel de Campo Pulsado , Enterococcus faecium/efeitos dos fármacos , Enterococcus faecium/genética , Enterococcus faecium/isolamento & purificação , Genótipo , Infecções por Bactérias Gram-Positivas/microbiologia , Humanos , Controle de Infecções , Testes de Sensibilidade Microbiana , Estudos Retrospectivos
4.
Nutrition ; 14(2): 165-72, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9530643

RESUMO

This study investigated the influence of an enteral diet supplemented with arginine, omega-3 fatty acids, and nucleotides (Impact, Sandoz Nutrition, Berne, Switzerland) on the incidence of systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) in patients after severe trauma. Thirty-two patients with an injury-severity score > 20 were included in this prospective, randomized, double-blind, controlled study. Primary endpoints were the incidence of SIRS and MOF. Secondary endpoints were parameters of acute phase and immune response as well as infection rate, mortality, and hospital stay. For statistical analysis 29 patients (test group n = 16, control n = 13) were eligible. In the test group, significantly fewer SIRS days per patient were found during 28 d. The difference was highly significant between d 8-14 (P < 0.001). MOF score was significantly lower in the test group on d 3 and d 8-11 (P < 0.05). Acute phase parameters showed lower C-reactive protein serum levels (significant on D day 4) and fibrinogen plasma levels (significant on d 12 and 14; P < 0.05). HLA-DR expression on monocytes showed significantly higher fluorescence activity on d 7. No significant difference was found for T-lymphocyte CD4/CD8 ratio, interleukin-2 receptor expression, infection rate, mortality (2/16 vs. 4/13), and hospital stay. The results of the study provide further support for beneficial effects of arginine, omega-3-fatty acids and nucleotide-supplemented enteral diet in critically ill patients.


Assuntos
Arginina/uso terapêutico , Ácidos Graxos Ômega-3/uso terapêutico , Insuficiência de Múltiplos Órgãos/prevenção & controle , Nucleotídeos/uso terapêutico , Síndrome de Resposta Inflamatória Sistêmica/prevenção & controle , Ferimentos e Lesões/terapia , Reação de Fase Aguda , Adolescente , Adulto , Arginina/administração & dosagem , Proteína C-Reativa/metabolismo , Nutrição Enteral , Antígenos HLA-DR/análise , Humanos , Pessoa de Meia-Idade , Monócitos/imunologia , Insuficiência de Múltiplos Órgãos/etiologia , Nucleotídeos/administração & dosagem , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Ferimentos e Lesões/complicações , Ferimentos e Lesões/imunologia
5.
Zentralbl Hyg Umweltmed ; 198(1): 84-95, 1995 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-9409897

RESUMO

In eleven centrally ventilated operating theatres the concentration of particles and airborne germs in wound vicinity was measured on three workdays. Five theatres were equipped with air supply ceilings with supporting flow outlets (supporting flow ceilings), five with laminar air flow ceilings and one with an air supply ceiling, a body exhaust system and a partition wall between the anesthetic and operating areas. Under routine conditions the air supply of the laminar air flow ceiling with its lower turbulence shielded the operating field from the largely staff-related air contamination in the rest of the theatre better than in the case of the supporting flow ceilings. Particles and airborne germs were removed from the endangered wound area faster. A spatial separation between the anesthetic and the operating areas as well as a body exhaust system lead to a considerable reduction of the contamination. Two theatres were conspicuous by reason of their considerably raised values due to defective control engineering and the wrongly positioning of the operating table. From the point of view of ventilation technique the laminar air flow ceilings with lower turbulence are superior to air supply ceilings with supporting flow outlets in the working day of an operating theatre. In order to minimize the influence of the staff, which up till now has been neglected in testing specifications, constructional possibilities such as the size of ceiling, the partitioning off of operating and anaesthetic areas and the positioning of the operating table in relation to the incoming air should be coordinated rationally. Taking measurements regularly during operations can provide the impulse for considerable improvements in both operational and planning phases.


Assuntos
Microbiologia do Ar , Poluentes Atmosféricos/análise , Poeira/análise , Salas Cirúrgicas , Ventilação , Desenho de Equipamento , Humanos
6.
Zentralbl Hyg Umweltmed ; 195(4): 306-18, 1994 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-8011060

RESUMO

On three days each we measured particles and airborne bacteria in ten ventilated operating theatres. Modern air conditioning systems achieved a significant reduction of air-pollution. Vertical systems proved to be more effective than horizontal systems. Workday conditions made several problems: During high personal activity a body exhaust system was not able to reduce the concentration of airborne bacteria; doors near the operating table and objects in the airstream had a negative effect; there was more personal than necessary in the operating theatres; some activities took place without a specific purpose and resulted in raised particle and bacteria contamination; early clearing of materials, before the operation ended, increased turbulences and door movements. A short break in personal activity before the first skin cut is recommended to reduce high air contamination due to the preparation of the operating room and the patient. One of the ventilation systems was insufficiently operated by personal. We recommend continuous measurement of particles near the operating field in order to control the input of airborne particles and bacteria into the wound.


Assuntos
Ar Condicionado , Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Salas Cirúrgicas , Ventilação , Poluição do Ar em Ambientes Fechados/prevenção & controle , Bactérias/crescimento & desenvolvimento , Humanos , Controle de Infecções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...