Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 122(1): 82-88, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27815367

RESUMO

Patients with chronic obstructive pulmonary disease (COPD) endure excessive resistive and elastic loads leading to chronic respiratory failure. Oxygen supplementation corrects hypoxemia but is not expected to reduce mechanical loads. Nasal high-flow (NHF) therapy supports breathing by reducing dead space, but it is unclear how it affects mechanical loads of patients with COPD. The objective of this study was to compare the effects of low-flow oxygen and NHF therapy on ventilation and work of breathing (WOB) in patients with COPD and controls during sleep. Patients with COPD (n = 12) and controls (n = 6) were recruited and submitted to polysomnography to measure sleep parameters and ventilation in response to administration of oxygen and NHF. A subset of six patients also had an esophageal catheter inserted for the purpose of measuring WOB. Patients with COPD had similar minute ventilation (V̇e) but lower tidal volumes than matched controls. With oxygen, [Formula: see text]was increased and V̇e was reduced in both controls and patients with COPD, but there was an increase in transcutaneous CO2 levels. NHF produced a greater reduction in V̇e and was associated with a reduction in CO2 levels. Although NHF halved WOB, oxygen produced only a minor reduction in this parameter. We conclude that oxygen produced little change in WOB, which was associated with CO2 elevations. On the other hand, NHF produced a large reduction in V̇e and WOB with a concomitant decrease in CO2 levels. Our data indicate that NHF improves alveolar ventilation during sleep compared with oxygen and room air in patients with COPD and therefore can decrease their cost of breathing. NEW & NOTEWORTHY: Nasal high-flow (NHF) therapy can support ventilation in patients with chronic obstructive pulmonary disease during sleep by decreasing the work of breathing and improving CO2 levels. On the other hand, oxygen supplementation corrects hypoxemia, but it produces only a minimal reduction in work of breathing and is associated with increased CO2 levels. Therefore, NHF can be a useful method to assist ventilation in patients with increased respiratory mechanical loads.


Assuntos
Mucosa Nasal/metabolismo , Oxigênio/metabolismo , Doença Pulmonar Obstrutiva Crônica/metabolismo , Sono/fisiologia , Fumar/metabolismo , Trabalho Respiratório/fisiologia , Dióxido de Carbono/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Ventilação Pulmonar/fisiologia , Respiração , Insuficiência Respiratória/metabolismo , Fumar/fisiopatologia , Volume de Ventilação Pulmonar/fisiologia
2.
Crit Care Med ; 37(10): 2733-9, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19885998

RESUMO

OBJECTIVE: To describe the composition of metabolic acidosis in patients with severe sepsis and septic shock at intensive care unit admission and throughout the first 5 days of intensive care unit stay. DESIGN: Prospective, observational study. SETTING: Twelve-bed intensive care unit. PATIENTS: Sixty patients with either severe sepsis or septic shock. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Data were collected until 5 days after intensive care unit admission. We studied the contribution of inorganic ion difference, lactate, albumin, phosphate, and strong ion gap to metabolic acidosis. At admission, standard base excess was -6.69 +/- 4.19 mEq/L in survivors vs. -11.63 +/- 4.87 mEq/L in nonsurvivors (p < .05); inorganic ion difference (mainly resulting from hyperchloremia) was responsible for a decrease in standard base excess by 5.64 +/- 4.96 mEq/L in survivors vs. 8.94 +/- 7.06 mEq/L in nonsurvivors (p < .05); strong ion gap was responsible for a decrease in standard base excess by 4.07 +/- 3.57 mEq/L in survivors vs. 4.92 +/- 5.55 mEq/L in nonsurvivors with a nonsignificant probability value; and lactate was responsible for a decrease in standard base excess to 1.34 +/- 2.07 mEq/L in survivors vs. 1.61 +/- 2.25 mEq/L in nonsurvivors with a nonsignificant probability value. Albumin had an important alkalinizing effect in both groups; phosphate had a minimal acid-base effect. Acidosis in survivors was corrected during the study period as a result of a decrease in lactate and strong ion gap levels, whereas nonsurvivors did not correct their metabolic acidosis. In addition to Acute Physiology and Chronic Health Evaluation II score and serum creatinine level,inorganic ion difference acidosis magnitude at intensive care unit admission was independently associated with a worse outcome. CONCLUSIONS: Patients with severe sepsis and septic shock exhibit a complex metabolic acidosis at intensive care unit admission, caused predominantly by hyperchloremic acidosis,which was more pronounced in nonsurvivors. Acidosis resolution in survivors was attributable to a decrease in strong ion gap and lactate levels.


Assuntos
Acidose/fisiopatologia , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Equilíbrio Ácido-Base/fisiologia , Acidose/diagnóstico , Acidose/mortalidade , Adulto , Idoso , Bicarbonatos/sangue , Cálcio/sangue , Dióxido de Carbono/sangue , Cloretos/sangue , Feminino , Mortalidade Hospitalar , Humanos , Concentração de Íons de Hidrogênio , Unidades de Terapia Intensiva , Ácido Láctico/sangue , Estudos Longitudinais , Magnésio/sangue , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Fosfatos/sangue , Prognóstico , Estudos Prospectivos , Albumina Sérica/análise , Sódio/sangue , Análise de Sobrevida , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/mortalidade
3.
Environ Res ; 109(5): 544-51, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19362299

RESUMO

OBJECTIVES: We investigated effects of chronic exposure (2 months) to ambient levels of particulate matter (PM) on development of protease-induced emphysema and pulmonary remodeling in mice. METHODS: Balb/c mice received nasal drop of either papain or normal saline and were kept in two exposure chambers situated in an area with high traffic density. One of them received ambient air and the other had filters for PM. RESULTS: mean concentration of PM10 was 2.68 +/- 0.38 and 33.86 +/- 2.09 microg/m3, respectively, in the filtered and ambient air chambers (p < 0.001). After 2 months of exposure, lungs from papain-treated mice kept in the chamber with ambient air presented greater values of mean linear intercept, an increase in density of collagen fibers in alveolar septa and in expression of 8-isoprostane (p = 0.002, p < 0.05 and p = 0.002, respectively, compared to papain-treated mice kept in the chamber with filtered air). We did not observe significant differences between these two groups in density of macrophages and in amount of cells expressing matrix metalloproteinase-12. There were no significant differences in saline-treated mice kept in the two chambers. CONCLUSIONS: We conclude that exposure to urban levels of PM worsens protease-induced emphysema and increases pulmonary remodeling. We suggest that an increase in oxidative stress induced by PM exposure influences this response. These pulmonary effects of PM were observed only in mice with emphysema.


Assuntos
Poluentes Atmosféricos/toxicidade , Enfisema/patologia , Emissões de Veículos , Animais , Imuno-Histoquímica , Exposição por Inalação , Macrófagos/efeitos dos fármacos , Metaloproteinase 12 da Matriz/metabolismo , Camundongos , Alvéolos Pulmonares/efeitos dos fármacos , Alvéolos Pulmonares/enzimologia , Alvéolos Pulmonares/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...