1.
Acta Orthop Scand ; 75(2): 217-20, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15180238

RESUMO

In 20 patients, we studied healing and time for complete integration of human cancellous bone allografts and the bovine substitute Lubboc on plain radiographs. They were all operated on because of benign tumors or tumor-like conditions, and followed until integration of the graft or for at least 1 year after operation. The median follow-up was 10 (2-40) months. Allografts showed a better integration than the bovine substitute. We conclude that allografts are to be preferred for these indications.


Assuntos
Neoplasias Ósseas/cirurgia , Transplante Ósseo/métodos , Osseointegração , Adolescente , Adulto , Idoso , Materiais Biocompatíveis/uso terapêutico , Osso e Ossos , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento , Cicatrização/fisiologia
2.
J Bone Joint Surg Am ; 85(11): 2168-73, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14630848

RESUMO

BACKGROUND: Systemic cobalt dissemination from the Metasul Co-28Cr-6Mo-0.2C metal-on-metal total hip prosthesis has been demonstrated in the first year after implantation. The aim of this prospective study was to monitor the serum cobalt concentrations in patients during the first five years after total hip arthroplasty with a metal-on-metal articulation. METHODS: A total hip arthroplasty was performed without cement in 100 consecutive patients who had either unilateral osteoarthritis or unilateral osteonecrosis. Fifty patients were randomized to be treated with a metal-on-metal articulation, and fifty patients, with a ceramic-on-polyethylene bearing. The femoral stem was made of a Ti-6Al-7Nb alloy, and the threaded acetabular cup was made of commercially pure titanium. Blood samples were taken before the operation and at multiple time-points for five years after the operation. Serum cobalt concentrations were measured with use of atomic absorption spectrometry. RESULTS: In the metal-on-metal group, the median serum cobalt concentration was 1 micro g/L at one year after surgery and 0.7 micro g/L at five years. The median of the serum cobalt concentrations measured from three to twelve months did not differ from the median of subsequent measurements, with the numbers available. The median serum cobalt level in the control group of patients treated with the ceramic-on-polyethylene articulation was below the detection limit at all time-points. CONCLUSIONS: Systemic cobalt release from Metasul metal-on-metal articulations was demonstrated throughout the five-year study period. The median serum cobalt concentrations were found to be slightly above the detection limit and remained in a constant range. The serum cobalt concentrations did not reflect a so-called run-in wear period of the metal-on-metal articulations.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Metais/sangue , Osteoartrite do Quadril/cirurgia , Osteonecrose/cirurgia , Adolescente , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Falha de Prótese