Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 94(4): 2126-2133, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35043638

RESUMO

SARS-CoV-2 diagnostic practices broadly involve either quantitative polymerase chain reaction (qPCR)-based nucleic amplification of viral sequences or antigen-based tests such as lateral flow assays (LFAs). Reverse transcriptase-qPCR can detect viral RNA and is the gold standard for sensitivity. However, the technique is time-consuming and requires expensive laboratory infrastructure and trained staff. LFAs are lower in cost and near real time, and because they are antigen-based, they have the potential to provide a more accurate indication of a disease state. However, LFAs are reported to have low real-world sensitivity and in most cases are only qualitative. Here, an antigen-based electrochemical aptamer sensor is presented, which has the potential to address some of these shortfalls. An aptamer, raised to the SARS-CoV-2 spike protein, was immobilized on a low-cost gold-coated polyester substrate adapted from the blood glucose testing industry. Clinically relevant detection levels for SARS-CoV-2 are achieved in a simple, label-free measurement format using sample incubation times as short as 15 min on nasopharyngeal swab samples. This assay can readily be optimized for mass manufacture and is compatible with a low-cost meter.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Espectroscopia Dielétrica , Eletrodos , Humanos , RNA Viral , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus
2.
Biosens Bioelectron ; 197: 113728, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34763151

RESUMO

The development of robust implantable sensors is important in the successful advancement of personalised medicine as they have the potential to provide in situ real-time data regarding the status of health and disease and the effectiveness of treatment. Tissue pH is a key physiological parameter and herein, we report the design, fabrication, functionalisation, encapsulation and protection of a miniaturised, self-contained, electrochemical pH sensor system and characterisation of sensor performance. Notably for the first time in this environment the pH sensor was based on a methylene blue redox reporter which showed remarkable robustness, accuracy and sensitivity. This was achieved by encapsulation of a self-assembled monolayer containing methylene blue entrapped within a Nafion layer. Another powerful feature was the incorporation, within the same implanted device, of a fabricated on-chip Ag/AgCl reference electrode - vital in any electrochemical sensor, but often ignored. When utilised in vivo, the sensor allowed accurate tracking of externally induced pH changes within a naturally occurring ovine lung cancer model, and correlated well with single point laboratory measurements made on extracted arterial blood, whilst enabling in vivo time-dependent measurements. The sensors functioned robustly whilst implanted, and maintained in vitro function once extracted and together, these results demonstrate proof-of-concept of the ability to sense real-time intratumoral tissue pH changes in vivo.


Assuntos
Técnicas Biossensoriais , Azul de Metileno , Animais , Técnicas Eletroquímicas , Concentração de Íons de Hidrogênio , Oxirredução , Ovinos
4.
Biosensors (Basel) ; 10(11)2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-33114106

RESUMO

Antibiotic resistance has been cited by the World Health Organisation (WHO) as one of the greatest threats to public health. Mitigating the spread of antibiotic resistance requires a multipronged approach with possible interventions including faster diagnostic testing and enhanced antibiotic stewardship. This study employs a low-cost diagnostic sensor test to rapidly pinpoint the correct antibiotic for treatment of infection. The sensor comprises a screen-printed gold electrode, modified with an antibiotic-seeded hydrogel to monitor bacterial growth. Electrochemical growth profiles of the common microorganism, Escherichia coli (E. coli) (ATCC 25922) were measured in the presence and absence of the antibiotic streptomycin. Results show a clear distinction between the E. coli growth profiles depending on whether streptomycin is present, in a timeframe of ≈2.5 h (p < 0.05), significantly quicker than the current gold standard of culture-based antimicrobial susceptibility testing. These results demonstrate a clear pathway to a low cost, phenotypic and reproducible antibiotic susceptibility testing technology for the rapid detection of E. coli within clinically relevant concentration ranges for conditions such as urinary tract infections.


Assuntos
Técnicas Biossensoriais , Eletrodos , Escherichia coli , Testes de Sensibilidade Microbiana/métodos , Antibacterianos , Resistência Microbiana a Medicamentos , Infecções por Escherichia coli , Humanos
5.
Am J Physiol Gastrointest Liver Physiol ; 317(2): G242-G252, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31188641

RESUMO

Recent advances in the fields of electronics and microfabrication techniques have led to the development of implantable medical devices for use within the field of precision medicine. Monitoring visceral surface tissue O2 tension (PTo2) by means of an implantable sensor is potentially useful in many clinical situations, including the perioperative management of patients undergoing intestinal resection and anastomosis. This concept could provide a means by which treatment could be tailored to individual patients. This study describes the in vivo validation of a novel, miniaturized electrochemical O2 sensor to provide real-time data on intestinal PTo2. A single O2 sensor was placed onto the serosal surface of the small intestine of anesthetized rats that were exposed to ischemic (superior mesenteric artery occlusion) and hypoxemic (alterations in inspired fractional O2 concentrations) insults. Control experiments demonstrated that the sensors can function and remain stable in an in vivo environment. Intestinal PTo2 decreased following superior mesenteric artery occlusion and with reductions in inspired O2 concentrations. These results were reversible after reinstating blood flow or by increasing inspired O2 concentrations. We have successfully developed an anesthetized rat intestinal ischemic and hypoxic model for validation of a miniaturized O2 sensor to provide real-time measurement of intestinal PTo2. Our results support further validation of the sensors in physiological conditions using a large animal model to provide evidence of their use in clinical applications where monitoring visceral surface tissue O2 tension is important.NEW & NOTEWORTHY This is the first report of real-time continuous measurements of intestinal oxygen tension made using a microfabricated O2 sensor. Using a developed rodent model, we have validated this sensor's ability to accurately measure dynamic and reversible changes in intestinal oxygenation that occur through ischemic and hypoxemic insults. Continuous monitoring of local intestinal oxygenation could have value in the postoperative monitoring of patients having undergone intestinal surgery.


Assuntos
Intestinos/irrigação sanguínea , Isquemia , Artéria Mesentérica Superior , Oclusão Vascular Mesentérica/complicações , Monitorização Fisiológica , Oxigênio , Animais , Precisão da Medição Dimensional , Isquemia/diagnóstico , Isquemia/etiologia , Teste de Materiais/métodos , Microtecnologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Oxigênio/análise , Oxigênio/química , Oxigênio/metabolismo , Consumo de Oxigênio , Ratos , Reprodutibilidade dos Testes , Tensão Superficial
6.
Biosens Bioelectron ; 134: 57-67, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30954927

RESUMO

This review article presents an overview of recent work on electrochemical biosensors developed using microfabrication processes, particularly sensors used to achieve sensitive and specific detection of DNA sequences. Such devices are important as they lend themselves to miniaturisation, reproducible mass-manufacture, and integration with other previously existing technologies and production methods. The review describes the current state of these biosensors, novel methods used to produce them or enhance their sensing properties, and pathways to deployment of a complete point-of-care biosensing system in a clinical setting.


Assuntos
Técnicas Biossensoriais/instrumentação , DNA/análise , Técnicas Eletroquímicas/instrumentação , Dispositivos Lab-On-A-Chip , Microtecnologia/instrumentação , Animais , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos , Desenho de Equipamento , Humanos , Microtecnologia/métodos
7.
J Biomed Mater Res B Appl Biomater ; 107(5): 1620-1633, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30367816

RESUMO

Real-time monitoring of tumor microenvironment parameters using an implanted biosensor could provide valuable information on the dynamic nature of a tumor's biology and its response to treatment. However, following implantation biosensors may lose functionality due to biofouling caused by the foreign body response (FBR). This study developed a novel tumor xenograft model to evaluate the potential of six biomaterials (silicon dioxide, silicon nitride, Parylene-C, Nafion, biocompatible EPOTEK epoxy resin, and platinum) to trigger a FBR when implanted into a solid tumor. Biomaterials were chosen based on their use in the construction of a novel biosensor, designed to measure spatial and temporal changes in intra-tumoral O2 , and pH. None of the biomaterials had any detrimental effect on tumor growth or body weight of the murine host. Immunohistochemistry showed no significant changes in tumor necrosis, hypoxic cell number, proliferation, apoptosis, immune cell infiltration, or collagen deposition. The absence of biofouling supports the use of these materials in biosensors; future investigations in preclinical cancer models are required, with a view to eventual applications in humans. To our knowledge this is the first documented investigation of the effects of modern biomaterials, used in the production of implantable sensors, on tumor tissue after implantation. © 2018 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. J Biomed Mater Res Part B, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1620-1633, 2019.


Assuntos
Materiais Biocompatíveis/química , Reação a Corpo Estranho/patologia , Próteses e Implantes , Materiais Inteligentes/química , Transplante Heterólogo/métodos , Animais , Materiais Biocompatíveis/metabolismo , Técnicas Biossensoriais/métodos , Linhagem Celular Tumoral , Colágeno/química , Resinas Epóxi/química , Feminino , Polímeros de Fluorcarboneto/química , Humanos , Camundongos , Neoplasias Experimentais , Platina/química , Polímeros/química , Compostos de Silício/química , Dióxido de Silício/química , Materiais Inteligentes/metabolismo , Microambiente Tumoral/efeitos dos fármacos , Xilenos/química
8.
Faraday Discuss ; 190: 351-66, 2016 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-27252128

RESUMO

Microelectrodes have a number of advantages over macroelectrodes for quantitative electroanalysis and monitoring, including reduced iR drop, a high signal-to-noise ratio and reduced sensitivity to convection. Their use in molten salts has been generally precluded by the combined materials challenges of stresses associated with thermal cycling and physical and corrosive chemical degradation at the relatively high temperatures involved. We have shown that microfabrication, employing high precision photolithographic patterning in combination with the controlled deposition of materials, can be used to successfully address these challenges. The resulting molten salt compatible microelectrodes (MSMs) enable prolonged quantitative microelectrode measurements in molten salts (MSs). This paper reports the fabrication of novel MSM disc electrodes, chosen because they have an established ambient analytical response. It includes a detailed set of electrochemical characterisation studies which demonstrate both their enhanced capability over macroelectrodes and over commercial glass pulled microelectrodes, and their ability to extract quantitative electroanalytical information from MS systems. MSM measurements are then used to demonstrate their potential for shedding new light on the fundamental properties of, and processes in, MSs, such as mass transport, charge transfer reaction rates and the selective plating/stripping and alloying reactions of liquid Bi and other metals; this will underpin the development of enhanced MS industrial processes, including pyrochemical spent nuclear fuel reprocessing.

9.
Anal Chem ; 86(22): 11342-8, 2014 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-25284431

RESUMO

Molten salts (MSs) are an attractive medium for chemical and electrochemical processing and as a result there is demand for MS-compatible analysis technologies. However, MSs containing redox species present a challenging environment in which to perform analytical measurements because of their corrosive nature, significant thermal convection and the high temperatures involved. This paper outlines the fabrication and characterization of microfabricated square microelectrodes (MSMs) designed for electrochemical analysis in MS systems. Their design enables precise control over electrode dimension, the minimization of stress because of differential thermal expansion through design for high temperature operation, and the minimization of corrosive attack through effective insulation. The exemplar MS system used for characterization was lithium chloride/potassium chloride eutectic (LKE), which has potential applications in pyrochemical nuclear fuel reprocessing, metal refining, molten salt batteries and electric power cells. The observed responses for a range of redox ions between 400 and 500 °C (673 and 773 K) were quantitative and typical of microelectrodes. MSMs also showed the reduced iR drop, steady-state diffusion-limited response, and reduced sensitivity to convection seen for microelectrodes under ambient conditions and expected for these electrodes in comparison to macroelectrodes. Diffusion coefficients were obtained in close agreement with literature values, more readily and at greater precision and accuracy than both macroelectrode and previous microelectrode measurements. The feasibility of extracting individual physical parameters from mixtures of redox species (as required in reprocessing) and of the prolonged measurement required for online monitoring was also demonstrated. Together, this demonstrates that MSMs provide enhanced electrode devices widely applicable to the characterization of redox species in a range of MS systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...