Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxicol In Vitro ; 49: 65-76, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28801046

RESUMO

Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids.


Assuntos
Córnea/citologia , Irritantes/classificação , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , Sobrevivência Celular/efeitos dos fármacos , Coelhos
2.
Toxicol In Vitro ; 27(8): 2175-83, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23999410

RESUMO

The aim of this study was to determine if the EpiDerm™ reconstructed human skin model (MatTek Corp.) could be an acceptable alternative to the ISO 10993-required rabbit skin irritation test for assessing medical device biocompatibility. Eleven medical device polymers were tested. Four extracts were prepared per polymer, two each with saline and sesame oil; half were spiked with two R-38 irritants, lactic acid for saline extracts and heptanoic acid for the sesame oil extracts. Tissue viability was assessed by MTT reduction and the proinflammatory response was assessed by IL-1α release. LOAELs of 2% for lactic acid in saline and 0.7% for heptanoic acid in sesame oil were determined. A cell viability reduction of >50% was indicative of skin irritation. Cells exposed to saline extracts spiked with 3.25% lactic acid had significantly reduced mean cell viabilities (12.6-17.2%). Cells exposed to sesame oil extracts spiked with 1.25% heptanoic acid also exhibited reduced mean cell viabilities (25.5%-41.7%). All spiked cells released substantial amounts of IL-1α (253.5-387.4pg/ml) signifying a proinflammatory response. These results indicate that the EpiDerm™ model may be a suitable in vitro replacement for the assessment of the irritation potential of medical device extracts.


Assuntos
Adesivos/química , Alternativas aos Testes com Animais , Misturas Complexas/toxicidade , Equipamentos e Provisões , Polímeros/química , Testes de Irritação da Pele , Sobrevivência Celular/efeitos dos fármacos , Dureza , Humanos , Técnicas In Vitro , Interleucina-1alfa/metabolismo , Óleo de Gergelim/química , Cloreto de Sódio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...