Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 20(2): 125-6, 1979 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-430185

RESUMO

We present two cases of myelomatous involvement of the skull. Correlative studies with routine radiography, angiography, and encephaloscintigraphy were performed. The areas of involvement of the skull were confirmed as autopsy. A mixed pattern of photon-deficient and photon-abundant lesions was noted. The clinician should be aware of such mixed patterns.


Assuntos
Mieloma Múltiplo/diagnóstico por imagem , Neoplasias Cranianas/diagnóstico por imagem , Idoso , Angiografia Cerebral , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Mieloma Múltiplo/irrigação sanguínea , Plasmocitoma/irrigação sanguínea , Plasmocitoma/diagnóstico por imagem , Cintilografia , Neoplasias Cranianas/irrigação sanguínea , Neoplasias de Tecidos Moles/irrigação sanguínea , Neoplasias de Tecidos Moles/diagnóstico por imagem , Tecnécio
2.
J Urol ; 120(5): 530-1, 1978 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-712890

RESUMO

After puncture of a renal cyst with a polytetrafluoroethylene needle a pediatric 0.021-inch guide wire is inserted through a polytetrafluoroethylene sheath needle. The sheath is then advanced over the wire. The technique is controlled by fluoroscopy or performed under ultrasonography. Aspiration of the contrast material is performed, and then air and diatrizoate meglumine and diatrizoate sodium are injected to outline the borders of the cyst. The patient is then taken to an upright and lateral radiographic changer for routine radiography in the upright and decubitus positions.


Assuntos
Doenças Renais Císticas/diagnóstico , Punções/métodos , Humanos , Rim/diagnóstico por imagem , Doenças Renais Císticas/diagnóstico por imagem , Radiografia
5.
Br Heart J ; 37(6): 647-51, 1975 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1148064

RESUMO

The myocardial clearance of rubidium may be obtained by praecordial counting after intravenous injection of Rb-minus 86 Cl. Eight patients with recent myocardial infarction had this determination performed before and after the infusion of 10 mg phentolamine at a rate of 0.3 mg/minute. The average predrug myocardial clearance of Rb was 89.3 plus or minus 29.9 ml/min per 100 g myocardium. After phentolamine, the average myocardial clearance rose to 117.3 plus or minus 33.3 ml/min per 100 g myocardium (P LESS THAN 0.01). An explanation for this findings is presented as well as its possible clinical applications.


Assuntos
Circulação Coronária/efeitos dos fármacos , Infarto do Miocárdio/tratamento farmacológico , Fentolamina/uso terapêutico , Adulto , Idoso , Feminino , Humanos , Infusões Parenterais , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Fentolamina/administração & dosagem , Fentolamina/farmacologia , Radioisótopos , Rubídio/metabolismo
6.
Cathet Cardiovasc Diagn ; 1(3): 267-74, 1975.
Artigo em Inglês | MEDLINE | ID: mdl-1222423

RESUMO

With the increased utilization of portable image intensifiers for pacemaker insertions, an investigation of the radiation hazards to operative personnel was undertaken. The personnel were tested first utilizing a Rando phantom and later during actual pacemaker insertions. Studies of medical personnel show the critical organs to be the thyroid (approximately 15mR per procedure) and the lens of the eye (approximately 13mR per procedure). While the MPD/week was not exceeded, the radiation dosage was substantial and could increase under operating conditions other than those measured. Recommendations to insure safer operation of this equipment are presented.


Assuntos
Marca-Passo Artificial , Monitoramento de Radiação , Tecnologia Radiológica , Fluoroscopia , Humanos , Aumento da Imagem , Cristalino , Concentração Máxima Permitida , Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Proteção Radiológica/normas , Glândula Tireoide , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...