Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Anaesth Analg ; 42(6): 614-22, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25689575

RESUMO

OBJECTIVE: To compare the agreement, repeatability and trending ability of transpulmonary thermodilution (TPTD) and pulmonary artery thermodilution (PATD) cardiac output (Q˙t) measurements in unsedated newborn calves. STUDY DESIGN: Prospective experimental trial. ANIMALS: Eight newborn calves weighing a median (range) of 53 (46-59) kg. METHODS: Pulmonary and femoral artery thermodilution catheters were placed under local anaesthesia. A total of 382 PATD and TPTD Q˙t measurements were performed simultaneously. Cardiac output was influenced by intravenous doxapram and theophylline in a randomized crossover fashion. Bland-Altman analysis for multiple comparisons, concordance and polar plots were used to assess TPTD against PATD. RESULTS: Median (range) cardiac index values measured with PATD and TPTD were 197 mL kg(-1) minute(-1) (74-335 mL kg(-1) minute(-1)) and 196 mL kg(-1) minute(-1) (59-395 mL kg(-1) minute(-1)), respec-tively. A small mean bias of -3 mL kg(-1) minute(-1) with limits of agreement (LOA) of -64 to 58 mL kg(-1) minute(-1) and a percentage error of 31% were found. Eighty-two mean values were calculated. This reduced the LOA to -50 to 41 mL kg(-1) minute(-1) with a similar small bias and a percentage error of 23%. Mean TPTD tracked changes in Q˙t compared with mean PATD with 90% concordance, a mean polar angle of 6° and radial LOA of 43°, indicating marginal trending ability. Keeping the femoral artery catheter patent and obtaining acceptable measurements were very challenging because the calves were not used to being restrained. Calf movement had less influence on PATD. CONCLUSIONS AND CLINICAL RELEVANCE: We recommend that PATD remains the reference method to measure Q˙t in unsedated newborn calves. However, the robust results of the evaluation of the less invasive TPTD technique warrants further evaluation taking into account the difficulties reported in this study.


Assuntos
Animais Recém-Nascidos/fisiologia , Débito Cardíaco/fisiologia , Bovinos/fisiologia , Artéria Pulmonar/fisiologia , Termodiluição/veterinária , Animais , Débito Cardíaco/efeitos dos fármacos , Estimulantes do Sistema Nervoso Central/farmacologia , Estudos Cross-Over , Doxapram/farmacologia , Feminino , Artéria Femoral/fisiologia , Masculino , Teofilina/farmacologia , Termodiluição/métodos , Vasodilatadores/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...