Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(12): 123502, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33380006

RESUMO

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ∼1 keV-20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight-an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. We present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×-25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

2.
Rev Sci Instrum ; 91(8): 083507, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872957

RESUMO

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. We present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources-where the exact details of spectral content were not thought to be crucial-we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

3.
Rev Sci Instrum ; 87(11): 11D421, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910608

RESUMO

Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility's diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

4.
Rev Sci Instrum ; 87(11): 11E330, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910695

RESUMO

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

5.
Phys Rev E ; 94(5-1): 051201, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27967028

RESUMO

We report experimental results and simulations showing efficient laser energy coupling into plasmas at conditions relevant to the magnetized liner inertial fusion (MagLIF) concept. In MagLIF, to limit convergence and increase the hydrodynamic stability of the implosion, the fuel must be efficiently preheated. To determine the efficiency and physics of preheating by a laser, an Ar plasma with n_{e}/n_{crit}∼0.04 is irradiated by a multi-ns, multi-kJ, 0.35-µm, phase-plate-smoothed laser at spot-averaged intensities ranging from 1.0×10^{14} to 2.5×10^{14}W/cm^{2} and pulse widths from 2 to 10 ns. Time-resolved x-ray images of the laser-heated plasma are compared to two-dimensional radiation-hydrodynamic simulations that show agreement with the propagating emission front, a comparison that constrains laser energy deposition to the plasma. The experiments show that long-pulse, modest-intensity (I=1.5×10^{14}W/cm^{2}) beams can efficiently couple energy (∼82% of the incident energy) to MagLIF-relevant long-length (9.5 mm) underdense plasmas. The demonstrated heating efficiency is significantly higher than is thought to have been achieved in early integrated MagLIF experiments [A. B. Sefkow et al., Phys. Plasmas 21, 072711 (2014)10.1063/1.4890298].

6.
Rev Sci Instrum ; 84(5): 055102, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742584

RESUMO

Cylindrical implosion offers a path to extreme material states, reaching considerably higher pressures than planar geometry. However, diagnosing compressed material in cylindrical geometry is challenging. Time-resolved velocimetry, a standard technique in planar compression, is difficult to incorporate into cylindrical experiments. This paper describes the use of photonic Doppler velocimetry (PDV) in magnetically driven cylindrical compression experiments at the Sandia Z machine. With this diagnostic, it is possible to track the interior of an imploding cylinder beyond 20 km/s. A "leapfrog" implementation is described to support velocities well above the bandwidth limits of standard PDV measurements.

7.
Phys Rev Lett ; 109(13): 135004, 2012 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-23030097

RESUMO

The implosions of initially solid beryllium liners (tubes) have been imaged with penetrating radiography through to stagnation. These novel radiographic data reveal a high degree of azimuthal correlation in the evolving magneto-Rayleigh-Taylor structure at times just prior to (and during) stagnation, providing stringent constraints on the simulation tools used by the broader high energy density physics and inertial confinement fusion communities. To emphasize this point, comparisons to 2D and 3D radiation magnetohydrodynamics simulations are also presented. Both agreement and substantial disagreement have been found, depending on how the liner's initial outer surface finish was modeled. The various models tested, and the physical implications of these models are discussed. These comparisons exemplify the importance of the experimental data obtained.

8.
Phys Rev Lett ; 105(18): 185001, 2010 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-21231110

RESUMO

The first controlled experiments measuring the growth of the magneto-Rayleigh-Taylor instability in fast (∼100 ns) Z-pinch plasmas are reported. Sinusoidal perturbations on the surface of an initially solid Al tube (liner) with wavelengths of 25-400 µm were used to seed the instability. Radiographs with 15 µm resolution captured the evolution of the outer liner surface. Comparisons with numerical radiation magnetohydrodynamic simulations show remarkably good agreement down to 50 µm wavelengths.

9.
Phys Rev Lett ; 101(5): 055001, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18764398

RESUMO

An ultrarelativistic 28.5 GeV, 700-microm-long positron bunch is focused near the entrance of a 1.4-m-long plasma with a density n(e) between approximately equal to 10(13) and approximately equal to 5 x 10(14) cm(-3). Partial neutralization of the bunch space charge by the mobile plasma electrons results in a reduction in transverse size by a factor of approximately equal to 3 in the high emittance plane of the beam approximately equal to 1 m downstream from the plasma exit. As n(e) increases, the formation of a beam halo containing approximately 40% of the total charge is observed, indicating that the plasma focusing force is nonlinear. Numerical simulations confirm these observations. The bunch with an incoming transverse size ratio of approximately 3 and emittance ratio of approximately 5 suffers emittance growth and exits the plasma with approximately equal sizes and emittances.

10.
Phys Rev Lett ; 94(9): 095005, 2005 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-15783974

RESUMO

The first hydrodynamic experiments were performed on the National Ignition Facility. A supersonic jet was formed via the interaction of a laser driven shock ( approximately 40 Mbar) with 2D and 3D density perturbations. The temporal evolution of the jet's spatial scales and ejected mass were measured with point-projection x-ray radiography. Measurements of the large-scale features and mass are in good agreement with 2D and 3D numerical simulations. These experiments provide quantitative data on the evolution of 3D supersonic jets and provide insight into their 3D behavior.

11.
Phys Rev Lett ; 90(20): 205002, 2003 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-12785902

RESUMO

We report on the first study of the dynamic transverse forces imparted to an ultrarelativistic positron beam by a long plasma in the underdense regime. Focusing of the 28.5 GeV beam is observed from time-resolved beam profiles after the 1.4 m plasma. The strength of the imparted force varies along the approximately 12 ps full length of the bunch as well as with plasma density. Computer simulations substantiate the longitudinal aberration seen in the data and reveal mechanisms for emittance degradation.

12.
Phys Rev Lett ; 90(21): 214801, 2003 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-12786559

RESUMO

Plasma wakefields are both excited and probed by propagating an intense 28.5 GeV positron beam through a 1.4 m long lithium plasma. The main body of the beam loses energy in exciting this wakefield while positrons in the back of the same beam can be accelerated by the same wakefield as it changes sign. The scaling of energy loss with plasma density as well as the energy gain seen at the highest plasma density is in excellent agreement with simulations.

13.
Phys Rev Lett ; 88(13): 135004, 2002 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-11955106

RESUMO

The successful utilization of an ion channel in a plasma to wiggle a 28.5-GeV electron beam to obtain broadband x-ray radiation is reported. The ion channel is induced by the electron bunch as it propagates through an underdense 1.4-meter-long lithium plasma. The quadratic density dependence of the spontaneously emitted betatron x-ray radiation and the divergence angle of approximately (1-3)x10(-4) radian of the forward-emitted x-rays as a consequence of betatron motion in the ion channel are in good agreement with theory. The absolute photon yield and the peak spectral brightness at 14.2-keV photon energy are estimated.

14.
Phys Rev Lett ; 88(15): 154801, 2002 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-11955201

RESUMO

The transverse dynamics of a 28.5-GeV electron beam propagating in a 1.4 m long, (0-2)x10(14) cm(-3) plasma are studied experimentally in the underdense or blowout regime. The transverse component of the wake field excited by the short electron bunch focuses the bunch, which experiences multiple betatron oscillations as the plasma density is increased. The spot-size variations are observed using optical transition radiation and Cherenkov radiation. In this regime, the behavior of the spot size as a function of the plasma density is well described by a simple beam-envelope model. Dynamic changes of the beam envelope are observed by time resolving the Cherenkov light.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...