Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39026755

RESUMO

Microsporidia are divergent fungal pathogens that employ a harpoon-like apparatus called the polar tube (PT) to invade host cells. The PT architecture and its association with neighboring organelles remain poorly understood. Here, we use cryo-electron tomography to investigate the structural cell biology of the PT in dormant spores from the human-infecting microsporidian species, Encephalitozoon intestinalis . Segmentation and subtomogram averaging of the PT reveal at least four layers: two protein-based layers surrounded by a membrane, and filled with a dense core. Regularly spaced protein filaments form the structural skeleton of the PT. Combining cryo-electron tomography with cellular modeling, we propose a model for the 3-dimensional organization of the polaroplast, an organelle that is continuous with the membrane layer that envelops the PT. Our results reveal the ultrastructure of the microsporidian invasion apparatus in situ , laying the foundation for understanding infection mechanisms.

2.
ACS Nano ; 17(18): 18470-18480, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37669408

RESUMO

Self-assembling virus-like particles (VLPs) can tolerate a wide degree of genetic and chemical manipulation to their capsid protein to display a foreign molecule polyvalently. We previously reported the successful incorporation of foreign peptide sequences in the junction loop and onto the C-terminus of PP7 dimer VLPs, as these regions are accessible for surface display on assembled capsids. Here, we report the implementation of a library-based approach to test the assembly tolerance of PP7 dimer capsid proteins to insertions or terminal extensions of randomized 15-mer peptide sequences. By performing two iterative rounds of assembly-based selection, we evaluated the degree of favorability of all 20 amino acids at each of the 15 randomized positions. Deep sequencing analysis revealed a distinct preference for the inclusion of hydrophilic peptides and negatively charged amino acids (Asp and Glu) and the exclusion of positively charged peptides and bulky and hydrophobic amino acid residues (Trp, Phe, Tyr, and Cys). Within the libraries tested here, we identified 4000 to 22,000 unique 15-mer peptide sequences that can successfully be displayed on the surface of the PP7 dimer capsid. Overall, the use of small initial libraries consisting of no more than a few million members yielded a significantly larger number of unique and assembly-competent VLP sequences than have been previously characterized for this class of nucleoprotein particle.


Assuntos
Aminoácidos , Peptídeos , Sequência de Aminoácidos , Capsídeo , Proteínas do Capsídeo/genética , Polímeros
4.
Microsc Microanal ; 29(Supplement_1): 954-955, 2023 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-37613651
5.
Front Mol Biosci ; 10: 1296941, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38288336

RESUMO

With the increasing spread of infectious diseases worldwide, there is an urgent need for novel strategies to combat them. Cryogenic sample electron microscopy (cryo-EM) techniques, particularly electron tomography (cryo-ET), have revolutionized the field of infectious disease research by enabling multiscale observation of biological structures in a near-native state. This review highlights the recent advances in infectious disease research using cryo-ET and discusses the potential of this structural biology technique to help discover mechanisms of infection in native environments and guiding in the right direction for future drug discovery.

6.
Nat Commun ; 13(1): 1857, 2022 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-35387991

RESUMO

Cryo-FIB/SEM combined with cryo-ET has emerged from within the field of cryo-EM as the method for obtaining the highest resolution structural information of complex biological samples in-situ in native and non-native environments. However, challenges remain in conventional cryo-FIB/SEM workflows, including milling thick specimens with vitrification issues, specimens with preferred orientation, low-throughput when milling small and/or low concentration specimens, and specimens that distribute poorly across grid squares. Here we present a general approach called the 'Waffle Method' which leverages high-pressure freezing to address these challenges. We illustrate the mitigation of these challenges by applying the Waffle Method and cryo-ET to reveal the macrostructure of the polar tube in microsporidian spores in multiple complementary orientations, which was previously not possible due to preferred orientation. We demonstrate the broadness of the Waffle Method by applying it to three additional cellular samples and a single particle sample using a variety of cryo-FIB-milling hardware, with manual and automated approaches. We also present a unique and critical stress-relief gap designed specifically for waffled lamellae. We propose the Waffle Method as a way to achieve many advantages of cryo-liftout on the specimen grid while avoiding the long, challenging, and technically-demanding process required for cryo-liftout.


Assuntos
Tomografia com Microscopia Eletrônica , Alimentos , Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Congelamento , Fluxo de Trabalho
7.
Bio Protoc ; 12(21)2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36618877

RESUMO

Cryo-focused ion beam (FIB) milling of vitrified specimens is emerging as a powerful method for in situ specimen preparation. It allows for the preservation of native and near-native conditions in cells, and can reveal the molecular structure of protein complexes when combined with cryo-electron tomography (cryo-ET) and sub-tomogram averaging. Cryo-FIB milling is often performed on plunge-frozen specimens of limited thickness. However, this approach may have several disadvantages, including low throughput for cells that are small, or at low concentration, or poorly distributed across accessible areas of the grid, as well as for samples that may adopt a preferred orientation. Here, we present a detailed description of the "Waffle Method" protocol for vitrifying thick specimens followed by a semi-automated milling procedure using the Thermo Fisher Scientific (TFS) Aquilos 2 cryo-FIB/scanning electron microscope (SEM) instrument and AutoTEM Cryo software to produce cryo-lamellae. With this protocol, cryo-lamellae may be generated from specimens, such as microsporidia spores, yeast, bacteria, and mammalian cells, as well as purified proteins and protein complexes. An experienced lab can perform the entire protocol presented here within an 8-hour working day, resulting in two to three cryo-lamellae with target thicknesses of 100-200 nm and dimensions of approximately 12 µm width and 15-20 µm length. For cryo-FIB/SEMs with particularly low-contamination chambers, the protocol can be extended to overnight milling, resulting in up to 16 cryo-lamellae in 24 h. Graphical abstract.

8.
Acta Crystallogr D Struct Biol ; 77(Pt 11): 1451-1459, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34726172

RESUMO

Thyroglobulin is a homodimeric glycoprotein that is essential for the generation of thyroid hormones in vertebrates. Upon secretion into the lumen of follicles in the thyroid gland, tyrosine residues within the protein become iodinated to produce monoiodotyrosine (MIT) and diiodotyrosine (DIT). A subset of evolutionarily conserved pairs of DIT (and MIT) residues can then engage in oxidative coupling reactions that yield either thyroxine (T4; produced from coupling of a DIT `acceptor' with a DIT `donor') or triiodothyronine (T3; produced from coupling of a DIT acceptor with an MIT donor). Although multiple iodotyrosine residues have been identified as potential donors and acceptors, the specificity and structural context of the pairings (i.e. which donor is paired with which acceptor) have remained unclear. Here, single-particle cryogenic electron microscopy (cryoEM) was used to generate a high-resolution reconstruction of bovine thyroglobulin (2.3 Šresolution in the core region and 2.6 Šoverall), allowing the structural characterization of two post-reaction acceptor-donor pairs as well as tyrosine residues modified as MIT and DIT. A substantial spatial separation between donor Tyr149 and acceptor Tyr24 was observed, suggesting that for thyroxine synthesis significant peptide motion is required for coupling at the evolutionarily conserved thyroglobulin amino-terminus.


Assuntos
Bovinos , Tireoglobulina/química , Animais , Bovinos/metabolismo , Microscopia Crioeletrônica , Halogenação , Conformação Proteica , Domínios Proteicos , Multimerização Proteica , Tireoglobulina/metabolismo , Tireoglobulina/ultraestrutura
9.
Nat Methods ; 17(9): 897-900, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32778833

RESUMO

We present an approach for preparing cryo-electron microscopy (cryo-EM) grids to study short-lived molecular states. Using piezoelectric dispensing, two independent streams of ~50-pl droplets of sample are deposited within 10 ms of each other onto the surface of a nanowire EM grid, and the mixing reaction stops when the grid is vitrified in liquid ethane ~100 ms later. We demonstrate this approach for four biological systems where short-lived states are of high interest.


Assuntos
Microscopia Crioeletrônica/métodos , Nanofios , Robótica , Manejo de Espécimes/métodos , Fatores de Tempo
10.
Front Mol Biosci ; 5: 50, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29951483

RESUMO

Cryo electron microscopy facilities running multiple instruments and serving users with varying skill levels need a robust and reliable method for benchmarking both the hardware and software components of their single particle analysis workflow. The workflow is complex, with many bottlenecks existing at the specimen preparation, data collection and image analysis steps; the samples and grid preparation can be of unpredictable quality, there are many different protocols for microscope and camera settings, and there is a myriad of software programs for analysis that can depend on dozens of settings chosen by the user. For this reason, we believe it is important to benchmark the entire workflow, using a standard sample and standard operating procedures, on a regular basis. This provides confidence that all aspects of the pipeline are capable of producing maps to high resolution. Here we describe benchmarking procedures using a test sample, rabbit muscle aldolase.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...