AIMS: The BRIGHT study evaluated bifocal right ventricular (RV) (apex and outflow tract) pacing in a single, blind, randomized crossover study in patients eligible for cardiac resynchronization therapy (CRT). Forty-two patients were enrolled with the following characteristics: chronic drug refractory heart failure New York Heart Association (NYHA) class III-IV; ejection fraction (EF)<35%; QRS width >or= 120 ms; and a left bundle branch block. The aim of the study was to assess an improvement in left ventricular (LV) EF, 6 min walk test, Minnesota quality-of-life score, and NYHA classification. Methods and result Patients were randomized to receive either bifocal pacing or the control mode, each for a period of 3 months. Parameters were measured prior to randomization and after 3 months of control or bifocal pacing. Eight patients failed to make the 7 month follow-up, three patients died (one prior to randomization at the first month), five patients dropped out, and three patients refused further participation. One patient had a persistent lead problem, which was subsequently replaced with an LV lead, and one patient suffered with persistent atrial fibrillation. Compared with baseline, bifocal pacing improved EF from 26 +/- 12% to 36 +/- 11% (P < 0.0008), NYHA classification decreased from 2.8 +/- 0.4 to 2.3 +/- 0.7 (P < 0.007). Furthermore, the 6 min walk test improved from 372 +/- 129 m to 453 +/- 122 m (P < 0.05), and the Minnesota Living with Heart Failure scores decreased from 33 +/- 20 to 24 +/- 21 (P < 0.006). In the control group, no significant changes in any parameters were observed. Eight patients did not tolerate reprogramming from DDD BRIGHT to control pacing, with symptoms disappearing in all patients after reprogramming to bifocal pacing. CONCLUSION: Bifocal RV pacing in patients with a classic indication for CRT shows improvement in all parameters.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Idoso , Fibrilação Atrial/etiologia , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Qualidade de Vida , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
2.
Pacing Clin Electrophysiol ; 28 Suppl 1: S36-8, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15683520

RESUMO

Bifocal RIGHT ventricular stimulation (BRIGHT) is an ongoing, randomized, single-blind, crossover study of atrial synchronized bi-right ventricular (RV) pacing in patients in New York Heart Association heart failure functional class III, a left ventricular ejection fraction <35%, left bundle branch block and QRS complexes >/=120 ms. This analysis compared the electrical and handling characteristics, and the complications of pacing at the RV apex (Ap) with passive, versus RV outflow tract (OT) with active fixation leads. A mean of 1.6 +/- 0.9 and 2.2 +/- 2.0 attempts were needed to position the Ap and OT leads, respectively (ns). R-wave amplitudes at Ap versus OT were 23 +/- 13 mV versus 14 +/- 8 mV (n = 36, P < 0.001). R-wave amplitudes at the Ap remained stable between implant and M7. R-wave amplitudes at the OT could not be measured after implantation. In two patients, atrioventricular block occurred during active fixation at the OT. Conduction recovered spontaneously within 4 months. Ventricular fibrillation was induced in one patient during manipulation of an Ap lead in the RV. Marked differences were found between leads positioned in the OT versus Ap, partly related to the difference in lead design. Mean R-wave amplitude was higher at the Ap that at the OT. Ease and success rate of lead implant was similar in both positions.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração , Idoso , Feminino , Humanos , Masculino , Projetos Piloto , Ensaios Clínicos Controlados Aleatórios como Assunto